Optimal timing of capsular tension ring implantation in pseudoexfoliation syndrome

Detalhes bibliográficos
Autor(a) principal: Ozturk,Emrah
Data de Publicação: 2021
Outros Autores: Gunduz,Abuzer
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492021000200158
Resumo: ABSTRACT Purpose: The aim of this study was to evaluate the appropriate timing of capsular tension ring implantation in cases of zonular weakness due to pseudoexfoliation syndrome. Methods: This prospective, comparative study was performed at the Ophthalmology Department of Inonu University, Malatya, Turkey. There were 43 patients included in the study. Group 1 (16 patients) had early capsular tension ring implantation, and group 2 (27 patients) had late capsular tension ring implantation. Patients with pseudoexfoliation syndrome who underwent phacoemulsification surgery, posterior chamber intraocular lens implantation, and capsular tension ring implantation were included in the study. Intraoperative complications and difficulties with either capsular tension ring implantation or cortex removal were evaluated in each eye. Results: There was no significant difference between the groups in the difficulty of capsular tension ring implantation (p=0.124). The difficulty of cortex removal differed significantly between the groups (p=0.003). Intraoperative complications were observed in 3 patients in group 1 and 11 patients in group 2; the difference between the groups was not significant (p=0.18). Posterior capsule fluctuations were observed in 8 patients (29.5%) in group 2, which resulted in posterior capsule rupture in 2 patients. Conclusions: Cortex removal is more difficult with early capsular tension ring implantation, and posterior capsule fluctuations may cause problems with late capsular tension ring implantation. The surgeon must consider the risk-to-benefit ratio of early versus late insertion for the optimal timing of capsular tension ring implantation.
id CBO-2_ec025be587a78c21f4d5683d3970a51b
oai_identifier_str oai:scielo:S0004-27492021000200158
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Optimal timing of capsular tension ring implantation in pseudoexfoliation syndromeCataractCapsular tension ringPhacoemulsificationABSTRACT Purpose: The aim of this study was to evaluate the appropriate timing of capsular tension ring implantation in cases of zonular weakness due to pseudoexfoliation syndrome. Methods: This prospective, comparative study was performed at the Ophthalmology Department of Inonu University, Malatya, Turkey. There were 43 patients included in the study. Group 1 (16 patients) had early capsular tension ring implantation, and group 2 (27 patients) had late capsular tension ring implantation. Patients with pseudoexfoliation syndrome who underwent phacoemulsification surgery, posterior chamber intraocular lens implantation, and capsular tension ring implantation were included in the study. Intraoperative complications and difficulties with either capsular tension ring implantation or cortex removal were evaluated in each eye. Results: There was no significant difference between the groups in the difficulty of capsular tension ring implantation (p=0.124). The difficulty of cortex removal differed significantly between the groups (p=0.003). Intraoperative complications were observed in 3 patients in group 1 and 11 patients in group 2; the difference between the groups was not significant (p=0.18). Posterior capsule fluctuations were observed in 8 patients (29.5%) in group 2, which resulted in posterior capsule rupture in 2 patients. Conclusions: Cortex removal is more difficult with early capsular tension ring implantation, and posterior capsule fluctuations may cause problems with late capsular tension ring implantation. The surgeon must consider the risk-to-benefit ratio of early versus late insertion for the optimal timing of capsular tension ring implantation.Conselho Brasileiro de Oftalmologia2021-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492021000200158Arquivos Brasileiros de Oftalmologia v.84 n.2 2021reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20210024info:eu-repo/semantics/openAccessOzturk,EmrahGunduz,Abuzereng2021-03-23T00:00:00Zoai:scielo:S0004-27492021000200158Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2021-03-23T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Optimal timing of capsular tension ring implantation in pseudoexfoliation syndrome
title Optimal timing of capsular tension ring implantation in pseudoexfoliation syndrome
spellingShingle Optimal timing of capsular tension ring implantation in pseudoexfoliation syndrome
Ozturk,Emrah
Cataract
Capsular tension ring
Phacoemulsification
title_short Optimal timing of capsular tension ring implantation in pseudoexfoliation syndrome
title_full Optimal timing of capsular tension ring implantation in pseudoexfoliation syndrome
title_fullStr Optimal timing of capsular tension ring implantation in pseudoexfoliation syndrome
title_full_unstemmed Optimal timing of capsular tension ring implantation in pseudoexfoliation syndrome
title_sort Optimal timing of capsular tension ring implantation in pseudoexfoliation syndrome
author Ozturk,Emrah
author_facet Ozturk,Emrah
Gunduz,Abuzer
author_role author
author2 Gunduz,Abuzer
author2_role author
dc.contributor.author.fl_str_mv Ozturk,Emrah
Gunduz,Abuzer
dc.subject.por.fl_str_mv Cataract
Capsular tension ring
Phacoemulsification
topic Cataract
Capsular tension ring
Phacoemulsification
description ABSTRACT Purpose: The aim of this study was to evaluate the appropriate timing of capsular tension ring implantation in cases of zonular weakness due to pseudoexfoliation syndrome. Methods: This prospective, comparative study was performed at the Ophthalmology Department of Inonu University, Malatya, Turkey. There were 43 patients included in the study. Group 1 (16 patients) had early capsular tension ring implantation, and group 2 (27 patients) had late capsular tension ring implantation. Patients with pseudoexfoliation syndrome who underwent phacoemulsification surgery, posterior chamber intraocular lens implantation, and capsular tension ring implantation were included in the study. Intraoperative complications and difficulties with either capsular tension ring implantation or cortex removal were evaluated in each eye. Results: There was no significant difference between the groups in the difficulty of capsular tension ring implantation (p=0.124). The difficulty of cortex removal differed significantly between the groups (p=0.003). Intraoperative complications were observed in 3 patients in group 1 and 11 patients in group 2; the difference between the groups was not significant (p=0.18). Posterior capsule fluctuations were observed in 8 patients (29.5%) in group 2, which resulted in posterior capsule rupture in 2 patients. Conclusions: Cortex removal is more difficult with early capsular tension ring implantation, and posterior capsule fluctuations may cause problems with late capsular tension ring implantation. The surgeon must consider the risk-to-benefit ratio of early versus late insertion for the optimal timing of capsular tension ring implantation.
publishDate 2021
dc.date.none.fl_str_mv 2021-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492021000200158
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492021000200158
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0004-2749.20210024
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.84 n.2 2021
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209031305560064