Whole-body MRI: comprehensive evaluation on a 48-channel 3T MRI system in less than 40 minutes. Preliminary results
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Radiologia Brasileira (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842012000600007 |
Resumo: | OBJECTIVE: To evaluate a comprehensive MRI protocol that investigates for cancer, vascular disease, and degenerative/inflammatory disease from the head to the pelvis in less than 40 minutes on a new generation 48-channel 3T system. MATERIALS AND METHODS: All MR studies were performed on a 48-channel 3T MR scanner. A 20-channel head/neck coil, two 18-channel body arrays, and a 32-channel spine array were employed. A total of 4 healthy individuals were studied. The designed protocol included a combination of single-shot T2-weighted sequences, T1-weighted 3D gradient-echo pre- and post-gadolinium. All images were retrospectively evaluated by two radiologists independently for overall image quality. RESULTS: The image quality for cancer was rated as excellent in the liver, pancreas, kidneys, lungs, pelvic organs, and brain, and rated as fair in the colon and breast. For vascular diseases ratings were excellent in the aorta, major branch vessel origins, inferior vena cava, portal and hepatic veins, rated as good in pulmonary arteries, and as poor in the coronary arteries. For degenerative/inflammatory diseases ratings were excellent in the brain, liver and pancreas. The inter-observer agreement was excellent. CONCLUSION: A comprehensive and time efficient screening for important categories of disease processes may be achieved with high quality imaging in a new generation 48-channel 3T system. |
id |
CBR-1_1a687f68e802a4a429648a4c6bfbe8eb |
---|---|
oai_identifier_str |
oai:scielo:S0100-39842012000600007 |
network_acronym_str |
CBR-1 |
network_name_str |
Radiologia Brasileira (Online) |
repository_id_str |
|
spelling |
Whole-body MRI: comprehensive evaluation on a 48-channel 3T MRI system in less than 40 minutes. Preliminary resultsWhole-body MRIScreeningProtocolPreliminary results3 teslaOBJECTIVE: To evaluate a comprehensive MRI protocol that investigates for cancer, vascular disease, and degenerative/inflammatory disease from the head to the pelvis in less than 40 minutes on a new generation 48-channel 3T system. MATERIALS AND METHODS: All MR studies were performed on a 48-channel 3T MR scanner. A 20-channel head/neck coil, two 18-channel body arrays, and a 32-channel spine array were employed. A total of 4 healthy individuals were studied. The designed protocol included a combination of single-shot T2-weighted sequences, T1-weighted 3D gradient-echo pre- and post-gadolinium. All images were retrospectively evaluated by two radiologists independently for overall image quality. RESULTS: The image quality for cancer was rated as excellent in the liver, pancreas, kidneys, lungs, pelvic organs, and brain, and rated as fair in the colon and breast. For vascular diseases ratings were excellent in the aorta, major branch vessel origins, inferior vena cava, portal and hepatic veins, rated as good in pulmonary arteries, and as poor in the coronary arteries. For degenerative/inflammatory diseases ratings were excellent in the brain, liver and pancreas. The inter-observer agreement was excellent. CONCLUSION: A comprehensive and time efficient screening for important categories of disease processes may be achieved with high quality imaging in a new generation 48-channel 3T system.Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem2012-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842012000600007Radiologia Brasileira v.45 n.6 2012reponame:Radiologia Brasileira (Online)instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)instacron:CBR10.1590/S0100-39842012000600007info:eu-repo/semantics/openAccessHernandes,Mateus de AndradeSemelka,Richard C.Elias Júnior,JorgeBamrungchart,SarapornDale,Brian M.Stallings,Cliftoneng2013-01-02T00:00:00Zoai:scielo:S0100-39842012000600007Revistahttps://www.scielo.br/j/rb/https://old.scielo.br/oai/scielo-oai.phpradiologiabrasileira@cbr.org.br1678-70990100-3984opendoar:2013-01-02T00:00Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)false |
dc.title.none.fl_str_mv |
Whole-body MRI: comprehensive evaluation on a 48-channel 3T MRI system in less than 40 minutes. Preliminary results |
title |
Whole-body MRI: comprehensive evaluation on a 48-channel 3T MRI system in less than 40 minutes. Preliminary results |
spellingShingle |
Whole-body MRI: comprehensive evaluation on a 48-channel 3T MRI system in less than 40 minutes. Preliminary results Hernandes,Mateus de Andrade Whole-body MRI Screening Protocol Preliminary results 3 tesla |
title_short |
Whole-body MRI: comprehensive evaluation on a 48-channel 3T MRI system in less than 40 minutes. Preliminary results |
title_full |
Whole-body MRI: comprehensive evaluation on a 48-channel 3T MRI system in less than 40 minutes. Preliminary results |
title_fullStr |
Whole-body MRI: comprehensive evaluation on a 48-channel 3T MRI system in less than 40 minutes. Preliminary results |
title_full_unstemmed |
Whole-body MRI: comprehensive evaluation on a 48-channel 3T MRI system in less than 40 minutes. Preliminary results |
title_sort |
Whole-body MRI: comprehensive evaluation on a 48-channel 3T MRI system in less than 40 minutes. Preliminary results |
author |
Hernandes,Mateus de Andrade |
author_facet |
Hernandes,Mateus de Andrade Semelka,Richard C. Elias Júnior,Jorge Bamrungchart,Saraporn Dale,Brian M. Stallings,Clifton |
author_role |
author |
author2 |
Semelka,Richard C. Elias Júnior,Jorge Bamrungchart,Saraporn Dale,Brian M. Stallings,Clifton |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Hernandes,Mateus de Andrade Semelka,Richard C. Elias Júnior,Jorge Bamrungchart,Saraporn Dale,Brian M. Stallings,Clifton |
dc.subject.por.fl_str_mv |
Whole-body MRI Screening Protocol Preliminary results 3 tesla |
topic |
Whole-body MRI Screening Protocol Preliminary results 3 tesla |
description |
OBJECTIVE: To evaluate a comprehensive MRI protocol that investigates for cancer, vascular disease, and degenerative/inflammatory disease from the head to the pelvis in less than 40 minutes on a new generation 48-channel 3T system. MATERIALS AND METHODS: All MR studies were performed on a 48-channel 3T MR scanner. A 20-channel head/neck coil, two 18-channel body arrays, and a 32-channel spine array were employed. A total of 4 healthy individuals were studied. The designed protocol included a combination of single-shot T2-weighted sequences, T1-weighted 3D gradient-echo pre- and post-gadolinium. All images were retrospectively evaluated by two radiologists independently for overall image quality. RESULTS: The image quality for cancer was rated as excellent in the liver, pancreas, kidneys, lungs, pelvic organs, and brain, and rated as fair in the colon and breast. For vascular diseases ratings were excellent in the aorta, major branch vessel origins, inferior vena cava, portal and hepatic veins, rated as good in pulmonary arteries, and as poor in the coronary arteries. For degenerative/inflammatory diseases ratings were excellent in the brain, liver and pancreas. The inter-observer agreement was excellent. CONCLUSION: A comprehensive and time efficient screening for important categories of disease processes may be achieved with high quality imaging in a new generation 48-channel 3T system. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842012000600007 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842012000600007 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0100-39842012000600007 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem |
publisher.none.fl_str_mv |
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem |
dc.source.none.fl_str_mv |
Radiologia Brasileira v.45 n.6 2012 reponame:Radiologia Brasileira (Online) instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) instacron:CBR |
instname_str |
Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) |
instacron_str |
CBR |
institution |
CBR |
reponame_str |
Radiologia Brasileira (Online) |
collection |
Radiologia Brasileira (Online) |
repository.name.fl_str_mv |
Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) |
repository.mail.fl_str_mv |
radiologiabrasileira@cbr.org.br |
_version_ |
1754208938129096704 |