Balloon-based adjuvant radiotherapy in breast cancer: comparison between 99mTc and HDR 192Ir

Detalhes bibliográficos
Autor(a) principal: Campos,Tarcísio Passos Ribeiro de
Data de Publicação: 2016
Outros Autores: Lima,Carla Flavia de, Cuperschmid,Ethel Mizrahy
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Radiologia Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842016000200009
Resumo: Abstract Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with 99mTc and balloon brachytherapy with high-dose-rate (HDR) 192Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and Methods: Simulations of implants with 99mTc-filled and HDR 192Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: The 99mTc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h-1.mCi-1 and 0.190 cGyh-1.mCi-1 at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh-1.mCi-1, respectively, for the HDR 192Ir balloon. An exposure time of 24 hours was required for the 99mTc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR 192Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: Temporary 99mTc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR 192Ir balloon implantation, which is the current standard in clinical practice.
id CBR-1_3eee9c490ef7320f8bf3efaa7540c052
oai_identifier_str oai:scielo:S0100-39842016000200009
network_acronym_str CBR-1
network_name_str Radiologia Brasileira (Online)
repository_id_str
spelling Balloon-based adjuvant radiotherapy in breast cancer: comparison between 99mTc and HDR 192IrBreast brachytherapyBalloonRadiotherapy dosageRadiotherapy, adjuvant99mTc192IrMonte Carlo methodAbstract Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with 99mTc and balloon brachytherapy with high-dose-rate (HDR) 192Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and Methods: Simulations of implants with 99mTc-filled and HDR 192Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: The 99mTc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h-1.mCi-1 and 0.190 cGyh-1.mCi-1 at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh-1.mCi-1, respectively, for the HDR 192Ir balloon. An exposure time of 24 hours was required for the 99mTc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR 192Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: Temporary 99mTc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR 192Ir balloon implantation, which is the current standard in clinical practice.Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem2016-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842016000200009Radiologia Brasileira v.49 n.2 2016reponame:Radiologia Brasileira (Online)instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)instacron:CBR10.1590/0100-3984.2015.0010info:eu-repo/semantics/openAccessCampos,Tarcísio Passos Ribeiro deLima,Carla Flavia deCuperschmid,Ethel Mizrahyeng2016-05-03T00:00:00Zoai:scielo:S0100-39842016000200009Revistahttps://www.scielo.br/j/rb/https://old.scielo.br/oai/scielo-oai.phpradiologiabrasileira@cbr.org.br1678-70990100-3984opendoar:2016-05-03T00:00Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)false
dc.title.none.fl_str_mv Balloon-based adjuvant radiotherapy in breast cancer: comparison between 99mTc and HDR 192Ir
title Balloon-based adjuvant radiotherapy in breast cancer: comparison between 99mTc and HDR 192Ir
spellingShingle Balloon-based adjuvant radiotherapy in breast cancer: comparison between 99mTc and HDR 192Ir
Campos,Tarcísio Passos Ribeiro de
Breast brachytherapy
Balloon
Radiotherapy dosage
Radiotherapy, adjuvant
99mTc
192Ir
Monte Carlo method
title_short Balloon-based adjuvant radiotherapy in breast cancer: comparison between 99mTc and HDR 192Ir
title_full Balloon-based adjuvant radiotherapy in breast cancer: comparison between 99mTc and HDR 192Ir
title_fullStr Balloon-based adjuvant radiotherapy in breast cancer: comparison between 99mTc and HDR 192Ir
title_full_unstemmed Balloon-based adjuvant radiotherapy in breast cancer: comparison between 99mTc and HDR 192Ir
title_sort Balloon-based adjuvant radiotherapy in breast cancer: comparison between 99mTc and HDR 192Ir
author Campos,Tarcísio Passos Ribeiro de
author_facet Campos,Tarcísio Passos Ribeiro de
Lima,Carla Flavia de
Cuperschmid,Ethel Mizrahy
author_role author
author2 Lima,Carla Flavia de
Cuperschmid,Ethel Mizrahy
author2_role author
author
dc.contributor.author.fl_str_mv Campos,Tarcísio Passos Ribeiro de
Lima,Carla Flavia de
Cuperschmid,Ethel Mizrahy
dc.subject.por.fl_str_mv Breast brachytherapy
Balloon
Radiotherapy dosage
Radiotherapy, adjuvant
99mTc
192Ir
Monte Carlo method
topic Breast brachytherapy
Balloon
Radiotherapy dosage
Radiotherapy, adjuvant
99mTc
192Ir
Monte Carlo method
description Abstract Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with 99mTc and balloon brachytherapy with high-dose-rate (HDR) 192Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and Methods: Simulations of implants with 99mTc-filled and HDR 192Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: The 99mTc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h-1.mCi-1 and 0.190 cGyh-1.mCi-1 at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh-1.mCi-1, respectively, for the HDR 192Ir balloon. An exposure time of 24 hours was required for the 99mTc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR 192Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: Temporary 99mTc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR 192Ir balloon implantation, which is the current standard in clinical practice.
publishDate 2016
dc.date.none.fl_str_mv 2016-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842016000200009
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842016000200009
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0100-3984.2015.0010
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
publisher.none.fl_str_mv Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
dc.source.none.fl_str_mv Radiologia Brasileira v.49 n.2 2016
reponame:Radiologia Brasileira (Online)
instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
instacron:CBR
instname_str Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
instacron_str CBR
institution CBR
reponame_str Radiologia Brasileira (Online)
collection Radiologia Brasileira (Online)
repository.name.fl_str_mv Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
repository.mail.fl_str_mv radiologiabrasileira@cbr.org.br
_version_ 1754208938960617472