QUANTIFICATION OF FUNGI AND BACTERIA TO EVALUATE INSIDE AIR IN A FIRM IN THE CENTRAL-WESTERN REGION OF THE STATE OF PARANÁ
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Saúde e Pesquisa (Online) |
Texto Completo: | https://periodicos.unicesumar.edu.br/index.php/saudpesq/article/view/2949 |
Resumo: | The quality of inside air in closed places is affected by several conditions such as premise structure, external environment, occupants´ habits and activities developed there. Pollution by micro-organisms, such as bacteria and fungi, may trigger the development of allergies, respiratory problems and other immunological reactions. It may be considered as one of the main environmental and public health problems. The concentration of fungi and bacteria in an agricultural-industrial firm in the central-western region of the state of Paraná, Brazil, is quantified to verify internal air pollution through basic parameters established by the National Agency for Sanitary Vigilance (ANVISA). Samples were collected by sedimentation methods in Petri plates during August and September 2012 during working hours, with the air-conditioning running on. Microbiological quality of the external air was also undertaken to compare inside and outside air. Concentrations of fungi and bacteria complied with limits permitted by Brazilian law (I/E < 1.5). It may be said that the internal air was of good quality with regard to concentrations of micro-organisms. |
id |
CESUMAR-1_8cceb3fab93322a52024c60d10a6d493 |
---|---|
oai_identifier_str |
oai:ojs.pkp.sfu.ca:article/2949 |
network_acronym_str |
CESUMAR-1 |
network_name_str |
Saúde e Pesquisa (Online) |
repository_id_str |
|
spelling |
QUANTIFICATION OF FUNGI AND BACTERIA TO EVALUATE INSIDE AIR IN A FIRM IN THE CENTRAL-WESTERN REGION OF THE STATE OF PARANÁQuantificação de Fungos e Bactérias Para Avaliação do Ar Interno de uma Empresa da Região Centro-Oeste do ParanáBio-AerosolQuality of Inside AirClimatizationBioaerossóisQualidade do Ar InternoClimatização.The quality of inside air in closed places is affected by several conditions such as premise structure, external environment, occupants´ habits and activities developed there. Pollution by micro-organisms, such as bacteria and fungi, may trigger the development of allergies, respiratory problems and other immunological reactions. It may be considered as one of the main environmental and public health problems. The concentration of fungi and bacteria in an agricultural-industrial firm in the central-western region of the state of Paraná, Brazil, is quantified to verify internal air pollution through basic parameters established by the National Agency for Sanitary Vigilance (ANVISA). Samples were collected by sedimentation methods in Petri plates during August and September 2012 during working hours, with the air-conditioning running on. Microbiological quality of the external air was also undertaken to compare inside and outside air. Concentrations of fungi and bacteria complied with limits permitted by Brazilian law (I/E < 1.5). It may be said that the internal air was of good quality with regard to concentrations of micro-organisms.A qualidade do ar interno dos ambientes fechados é influenciada por várias condições, tais como: estrutura dos prédios, ambiente externo, rotina dos ocupantes, além das atividades desenvolvidas neste ambiente. A poluição por micro-organismos, como bactérias e fungos, pode levar ao desenvolvimento de doenças alérgicas, problemas respiratórios e outras reações imunológicas e pode ser considerada como um dos principais problemas ambientais e de saúde pública. Este trabalho teve por objetivo quantificar a concentração de fungos e bactérias de uma empresa do setor agroindustrial da região centro-oeste do Paraná, com a finalidade de verificar a poluição do ar interno deste ambiente, observando os parâmetros básicos estabelecidos pela Agencia Nacional de Vigilância Sanitária (ANVISA). As amostras foram coletadas utilizando-se o método de sedimentação em placas de Petri durante os meses de agosto e setembro de 2012, no horário de funcionamento da empresa em que o ar condicionado estava ligado. Foi realizada, também, a análise da qualidade microbiológica do ar externo da empresa, para que a análise comparativa entre o ar interno e o ar externo fosse realizada. Diante do exposto, as concentrações de fungos e bactérias encontravam-se de acordo com o limite permitido pela legislação vigente (I/E < 1,5). Podemos afirmar, dessa forma, que o ar interno da empresa apresenta uma boa qualidade, no que diz respeito à concentração de micro-organismos.Universidade Cesumar - UniCesumar2013-12-12info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionAvaliado por Paresapplication/pdfhttps://periodicos.unicesumar.edu.br/index.php/saudpesq/article/view/2949Saúde e Pesquisa; Vol 6 No 3 (2013): set./dez.Saúde e Pesquisa; v. 6 n. 3 (2013): set./dez.2176-9206reponame:Saúde e Pesquisa (Online)instname:Cesumar Diretoria de Pesquisainstacron:CESUMARporhttps://periodicos.unicesumar.edu.br/index.php/saudpesq/article/view/2949/2156Cunha, Viviane Augusta Medeiros GarciaOliveira, Daiane Aparecida BuzzattoBombana, Camila CristinaPavanelli, Mariana FelgueiraParussolo, Leandroinfo:eu-repo/semantics/openAccess2020-09-04T12:39:06Zoai:ojs.pkp.sfu.ca:article/2949Revistahttps://periodicos.unicesumar.edu.br/index.php/saudpesqPUBhttps://periodicos.unicesumar.edu.br/index.php/saudpesq/oainaep@cesumar.br2176-92061983-1870opendoar:2020-09-04T12:39:06Saúde e Pesquisa (Online) - Cesumar Diretoria de Pesquisafalse |
dc.title.none.fl_str_mv |
QUANTIFICATION OF FUNGI AND BACTERIA TO EVALUATE INSIDE AIR IN A FIRM IN THE CENTRAL-WESTERN REGION OF THE STATE OF PARANÁ Quantificação de Fungos e Bactérias Para Avaliação do Ar Interno de uma Empresa da Região Centro-Oeste do Paraná |
title |
QUANTIFICATION OF FUNGI AND BACTERIA TO EVALUATE INSIDE AIR IN A FIRM IN THE CENTRAL-WESTERN REGION OF THE STATE OF PARANÁ |
spellingShingle |
QUANTIFICATION OF FUNGI AND BACTERIA TO EVALUATE INSIDE AIR IN A FIRM IN THE CENTRAL-WESTERN REGION OF THE STATE OF PARANÁ Cunha, Viviane Augusta Medeiros Garcia Bio-Aerosol Quality of Inside Air Climatization Bioaerossóis Qualidade do Ar Interno Climatização . |
title_short |
QUANTIFICATION OF FUNGI AND BACTERIA TO EVALUATE INSIDE AIR IN A FIRM IN THE CENTRAL-WESTERN REGION OF THE STATE OF PARANÁ |
title_full |
QUANTIFICATION OF FUNGI AND BACTERIA TO EVALUATE INSIDE AIR IN A FIRM IN THE CENTRAL-WESTERN REGION OF THE STATE OF PARANÁ |
title_fullStr |
QUANTIFICATION OF FUNGI AND BACTERIA TO EVALUATE INSIDE AIR IN A FIRM IN THE CENTRAL-WESTERN REGION OF THE STATE OF PARANÁ |
title_full_unstemmed |
QUANTIFICATION OF FUNGI AND BACTERIA TO EVALUATE INSIDE AIR IN A FIRM IN THE CENTRAL-WESTERN REGION OF THE STATE OF PARANÁ |
title_sort |
QUANTIFICATION OF FUNGI AND BACTERIA TO EVALUATE INSIDE AIR IN A FIRM IN THE CENTRAL-WESTERN REGION OF THE STATE OF PARANÁ |
author |
Cunha, Viviane Augusta Medeiros Garcia |
author_facet |
Cunha, Viviane Augusta Medeiros Garcia Oliveira, Daiane Aparecida Buzzatto Bombana, Camila Cristina Pavanelli, Mariana Felgueira Parussolo, Leandro |
author_role |
author |
author2 |
Oliveira, Daiane Aparecida Buzzatto Bombana, Camila Cristina Pavanelli, Mariana Felgueira Parussolo, Leandro |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Cunha, Viviane Augusta Medeiros Garcia Oliveira, Daiane Aparecida Buzzatto Bombana, Camila Cristina Pavanelli, Mariana Felgueira Parussolo, Leandro |
dc.subject.por.fl_str_mv |
Bio-Aerosol Quality of Inside Air Climatization Bioaerossóis Qualidade do Ar Interno Climatização . |
topic |
Bio-Aerosol Quality of Inside Air Climatization Bioaerossóis Qualidade do Ar Interno Climatização . |
description |
The quality of inside air in closed places is affected by several conditions such as premise structure, external environment, occupants´ habits and activities developed there. Pollution by micro-organisms, such as bacteria and fungi, may trigger the development of allergies, respiratory problems and other immunological reactions. It may be considered as one of the main environmental and public health problems. The concentration of fungi and bacteria in an agricultural-industrial firm in the central-western region of the state of Paraná, Brazil, is quantified to verify internal air pollution through basic parameters established by the National Agency for Sanitary Vigilance (ANVISA). Samples were collected by sedimentation methods in Petri plates during August and September 2012 during working hours, with the air-conditioning running on. Microbiological quality of the external air was also undertaken to compare inside and outside air. Concentrations of fungi and bacteria complied with limits permitted by Brazilian law (I/E < 1.5). It may be said that the internal air was of good quality with regard to concentrations of micro-organisms. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-12-12 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Avaliado por Pares |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://periodicos.unicesumar.edu.br/index.php/saudpesq/article/view/2949 |
url |
https://periodicos.unicesumar.edu.br/index.php/saudpesq/article/view/2949 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://periodicos.unicesumar.edu.br/index.php/saudpesq/article/view/2949/2156 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Cesumar - UniCesumar |
publisher.none.fl_str_mv |
Universidade Cesumar - UniCesumar |
dc.source.none.fl_str_mv |
Saúde e Pesquisa; Vol 6 No 3 (2013): set./dez. Saúde e Pesquisa; v. 6 n. 3 (2013): set./dez. 2176-9206 reponame:Saúde e Pesquisa (Online) instname:Cesumar Diretoria de Pesquisa instacron:CESUMAR |
instname_str |
Cesumar Diretoria de Pesquisa |
instacron_str |
CESUMAR |
institution |
CESUMAR |
reponame_str |
Saúde e Pesquisa (Online) |
collection |
Saúde e Pesquisa (Online) |
repository.name.fl_str_mv |
Saúde e Pesquisa (Online) - Cesumar Diretoria de Pesquisa |
repository.mail.fl_str_mv |
naep@cesumar.br |
_version_ |
1754122532973182976 |