Assessment of surface friction of self-ligating brackets under conditions of angulated traction

Detalhes bibliográficos
Autor(a) principal: Buzzoni,Roberta
Data de Publicação: 2012
Outros Autores: Elias,Carlos N., Fernandes,Daniel J., Miguel,José Augusto M.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Dental Press Journal of Orthodontics
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512012000400013
Resumo: OBJECTIVE: The aim of this study was to assess resistance to sliding of stainless steel passive self-ligating brackets with 0° and 2.5° angulations and to compare them to active self-ligating brackets at zero angulation. The hypothesis to be tested was that passive self-ligating brackets produce lower frictional forces than active self-ligating brackets. METHODS: Twenty five 0.022 x 0.028-in slot maxillary canine brackets were divided into 5 groups of 5 brackets: Damon SL II (Ormco, CA, USA) self-ligating bracket and Gemini (3M/Unitek, CA, USA) conventional bracket with angulation of 0 and 2.5° and a group of Speed 2 (American Orthodontics, WI, USA) active clip self-ligating system with zero angulation. Twenty five segments of stainless steel 0.020-in archwire (TP Orthodontics, IN, USA) were tested and each bracket/wire interface was evaluated at 4 successive points during sliding. Overall, 100 frictional values were analyzed by parametric analysis of variance and Bonferroni tests. RESULTS AND CONCLUSION: Frictional tests were performed with an Emic DL 10000 testing machine (Emic, Brazil) with a load cell of one kilogram. Passive self-ligating brackets produced lower frictional forces than active self-ligating brackets (p < 0.01). Under angulation, brackets with a slide mechanism produced higher friction than the same brackets under zero angulation (p < 0.01). Nevertheless, the slide system under angulation produced smaller friction values than conventional brackets tied with elastomeric ligatures in 0° tests.
id DPI-1_69ada58bc6a3dba56f2032ac36bfe4be
oai_identifier_str oai:scielo:S2176-94512012000400013
network_acronym_str DPI-1
network_name_str Dental Press Journal of Orthodontics
repository_id_str
spelling Assessment of surface friction of self-ligating brackets under conditions of angulated tractionOrthodontic bracketsFrictionStainless steelLigationOBJECTIVE: The aim of this study was to assess resistance to sliding of stainless steel passive self-ligating brackets with 0° and 2.5° angulations and to compare them to active self-ligating brackets at zero angulation. The hypothesis to be tested was that passive self-ligating brackets produce lower frictional forces than active self-ligating brackets. METHODS: Twenty five 0.022 x 0.028-in slot maxillary canine brackets were divided into 5 groups of 5 brackets: Damon SL II (Ormco, CA, USA) self-ligating bracket and Gemini (3M/Unitek, CA, USA) conventional bracket with angulation of 0 and 2.5° and a group of Speed 2 (American Orthodontics, WI, USA) active clip self-ligating system with zero angulation. Twenty five segments of stainless steel 0.020-in archwire (TP Orthodontics, IN, USA) were tested and each bracket/wire interface was evaluated at 4 successive points during sliding. Overall, 100 frictional values were analyzed by parametric analysis of variance and Bonferroni tests. RESULTS AND CONCLUSION: Frictional tests were performed with an Emic DL 10000 testing machine (Emic, Brazil) with a load cell of one kilogram. Passive self-ligating brackets produced lower frictional forces than active self-ligating brackets (p < 0.01). Under angulation, brackets with a slide mechanism produced higher friction than the same brackets under zero angulation (p < 0.01). Nevertheless, the slide system under angulation produced smaller friction values than conventional brackets tied with elastomeric ligatures in 0° tests.Dental Press International2012-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512012000400013Dental Press Journal of Orthodontics v.17 n.4 2012reponame:Dental Press Journal of Orthodonticsinstname:Dental Press International (DPI)instacron:DPI10.1590/S2176-94512012000400013info:eu-repo/semantics/openAccessBuzzoni,RobertaElias,Carlos N.Fernandes,Daniel J.Miguel,José Augusto M.eng2012-10-17T00:00:00Zoai:scielo:S2176-94512012000400013Revistahttp://www.scielo.br/dpjoONGhttps://old.scielo.br/oai/scielo-oai.phpartigos@dentalpress.com.br||davidnormando@hotmail.com2177-67092176-9451opendoar:2012-10-17T00:00Dental Press Journal of Orthodontics - Dental Press International (DPI)false
dc.title.none.fl_str_mv Assessment of surface friction of self-ligating brackets under conditions of angulated traction
title Assessment of surface friction of self-ligating brackets under conditions of angulated traction
spellingShingle Assessment of surface friction of self-ligating brackets under conditions of angulated traction
Buzzoni,Roberta
Orthodontic brackets
Friction
Stainless steel
Ligation
title_short Assessment of surface friction of self-ligating brackets under conditions of angulated traction
title_full Assessment of surface friction of self-ligating brackets under conditions of angulated traction
title_fullStr Assessment of surface friction of self-ligating brackets under conditions of angulated traction
title_full_unstemmed Assessment of surface friction of self-ligating brackets under conditions of angulated traction
title_sort Assessment of surface friction of self-ligating brackets under conditions of angulated traction
author Buzzoni,Roberta
author_facet Buzzoni,Roberta
Elias,Carlos N.
Fernandes,Daniel J.
Miguel,José Augusto M.
author_role author
author2 Elias,Carlos N.
Fernandes,Daniel J.
Miguel,José Augusto M.
author2_role author
author
author
dc.contributor.author.fl_str_mv Buzzoni,Roberta
Elias,Carlos N.
Fernandes,Daniel J.
Miguel,José Augusto M.
dc.subject.por.fl_str_mv Orthodontic brackets
Friction
Stainless steel
Ligation
topic Orthodontic brackets
Friction
Stainless steel
Ligation
description OBJECTIVE: The aim of this study was to assess resistance to sliding of stainless steel passive self-ligating brackets with 0° and 2.5° angulations and to compare them to active self-ligating brackets at zero angulation. The hypothesis to be tested was that passive self-ligating brackets produce lower frictional forces than active self-ligating brackets. METHODS: Twenty five 0.022 x 0.028-in slot maxillary canine brackets were divided into 5 groups of 5 brackets: Damon SL II (Ormco, CA, USA) self-ligating bracket and Gemini (3M/Unitek, CA, USA) conventional bracket with angulation of 0 and 2.5° and a group of Speed 2 (American Orthodontics, WI, USA) active clip self-ligating system with zero angulation. Twenty five segments of stainless steel 0.020-in archwire (TP Orthodontics, IN, USA) were tested and each bracket/wire interface was evaluated at 4 successive points during sliding. Overall, 100 frictional values were analyzed by parametric analysis of variance and Bonferroni tests. RESULTS AND CONCLUSION: Frictional tests were performed with an Emic DL 10000 testing machine (Emic, Brazil) with a load cell of one kilogram. Passive self-ligating brackets produced lower frictional forces than active self-ligating brackets (p < 0.01). Under angulation, brackets with a slide mechanism produced higher friction than the same brackets under zero angulation (p < 0.01). Nevertheless, the slide system under angulation produced smaller friction values than conventional brackets tied with elastomeric ligatures in 0° tests.
publishDate 2012
dc.date.none.fl_str_mv 2012-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512012000400013
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512012000400013
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S2176-94512012000400013
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Dental Press International
publisher.none.fl_str_mv Dental Press International
dc.source.none.fl_str_mv Dental Press Journal of Orthodontics v.17 n.4 2012
reponame:Dental Press Journal of Orthodontics
instname:Dental Press International (DPI)
instacron:DPI
instname_str Dental Press International (DPI)
instacron_str DPI
institution DPI
reponame_str Dental Press Journal of Orthodontics
collection Dental Press Journal of Orthodontics
repository.name.fl_str_mv Dental Press Journal of Orthodontics - Dental Press International (DPI)
repository.mail.fl_str_mv artigos@dentalpress.com.br||davidnormando@hotmail.com
_version_ 1754122396008185856