Evaluation of the lower incisor inclination during alignment and leveling using superelastic NiTi archwires: a laboratory study
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Dental Press Journal of Orthodontics |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512012000300013 |
Resumo: | OBJECTIVE: The aim of this laboratory study is to evaluate the influence of the shape and the length limitation of superelastic nickel-titanium (NiTi) archwires on lower incisors inclination during alignment and leveling. METHODS: Metal teeth mounted on a typodont articulator device were used to simulate a malocclusion of the mandibular arch (-3.5 mm model discrepancy). Three different shapes (Standard, Accuform and Ideal) of superelastic NiTi archwires (Sentalloy, GAC, USA) were tested. Specimens were divided in two groups: Group I, with no limitation of the archwire length; and Group II, with distal limitation. Each group had thirty specimens divided into three subgroups differentiated by the archwire shape. All groups used round wires with diameters of 0.014-in, 0.016-in, 0.018-in and 0.020-in. The recording of all intervals was accomplished using standardized digital photographs with orthogonal norm in relation to median sagittal plane. The buccolingual inclination of the incisor was registered using photographs and software CorelDraw. RESULTS: The results were obtained using ANOVA and Tukey's test at a significant level of 5%. The inclination of the lower incisor increased in both groups and subgroups. The shape of the archwire had statistically significant influence only in Group I - Standard (11.76º), Ideal (5.88º) and Accuform (1.93º). Analyzing the influence of the length limitation, despite the mean incisor tipping in Group II (3.91º) had been smaller than Group I (6.52º), no statistically significant difference was found, except for Standard, 3.89º with limitation and 11.76º without limitation. The greatest incisor tipping occurred with the 0.014-in archwires. |
id |
DPI-1_956c4ee86f035f7c6ce625ffb9842f03 |
---|---|
oai_identifier_str |
oai:scielo:S2176-94512012000300013 |
network_acronym_str |
DPI-1 |
network_name_str |
Dental Press Journal of Orthodontics |
repository_id_str |
|
spelling |
Evaluation of the lower incisor inclination during alignment and leveling using superelastic NiTi archwires: a laboratory studyArch shapeSuperelastic NiTi archwireArch lengthIncisor tippingOBJECTIVE: The aim of this laboratory study is to evaluate the influence of the shape and the length limitation of superelastic nickel-titanium (NiTi) archwires on lower incisors inclination during alignment and leveling. METHODS: Metal teeth mounted on a typodont articulator device were used to simulate a malocclusion of the mandibular arch (-3.5 mm model discrepancy). Three different shapes (Standard, Accuform and Ideal) of superelastic NiTi archwires (Sentalloy, GAC, USA) were tested. Specimens were divided in two groups: Group I, with no limitation of the archwire length; and Group II, with distal limitation. Each group had thirty specimens divided into three subgroups differentiated by the archwire shape. All groups used round wires with diameters of 0.014-in, 0.016-in, 0.018-in and 0.020-in. The recording of all intervals was accomplished using standardized digital photographs with orthogonal norm in relation to median sagittal plane. The buccolingual inclination of the incisor was registered using photographs and software CorelDraw. RESULTS: The results were obtained using ANOVA and Tukey's test at a significant level of 5%. The inclination of the lower incisor increased in both groups and subgroups. The shape of the archwire had statistically significant influence only in Group I - Standard (11.76º), Ideal (5.88º) and Accuform (1.93º). Analyzing the influence of the length limitation, despite the mean incisor tipping in Group II (3.91º) had been smaller than Group I (6.52º), no statistically significant difference was found, except for Standard, 3.89º with limitation and 11.76º without limitation. The greatest incisor tipping occurred with the 0.014-in archwires.Dental Press International2012-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512012000300013Dental Press Journal of Orthodontics v.17 n.3 2012reponame:Dental Press Journal of Orthodonticsinstname:Dental Press International (DPI)instacron:DPI10.1590/S2176-94512012000300013info:eu-repo/semantics/openAccessBaratieri,CarolinaRocha,RobertoCampos,CarolineMenezes,LucianeRibeiro,Gerson Luiz UlemaRitter,DaltroBorgato,Adrianoeng2012-08-16T00:00:00Zoai:scielo:S2176-94512012000300013Revistahttp://www.scielo.br/dpjoONGhttps://old.scielo.br/oai/scielo-oai.phpartigos@dentalpress.com.br||davidnormando@hotmail.com2177-67092176-9451opendoar:2012-08-16T00:00Dental Press Journal of Orthodontics - Dental Press International (DPI)false |
dc.title.none.fl_str_mv |
Evaluation of the lower incisor inclination during alignment and leveling using superelastic NiTi archwires: a laboratory study |
title |
Evaluation of the lower incisor inclination during alignment and leveling using superelastic NiTi archwires: a laboratory study |
spellingShingle |
Evaluation of the lower incisor inclination during alignment and leveling using superelastic NiTi archwires: a laboratory study Baratieri,Carolina Arch shape Superelastic NiTi archwire Arch length Incisor tipping |
title_short |
Evaluation of the lower incisor inclination during alignment and leveling using superelastic NiTi archwires: a laboratory study |
title_full |
Evaluation of the lower incisor inclination during alignment and leveling using superelastic NiTi archwires: a laboratory study |
title_fullStr |
Evaluation of the lower incisor inclination during alignment and leveling using superelastic NiTi archwires: a laboratory study |
title_full_unstemmed |
Evaluation of the lower incisor inclination during alignment and leveling using superelastic NiTi archwires: a laboratory study |
title_sort |
Evaluation of the lower incisor inclination during alignment and leveling using superelastic NiTi archwires: a laboratory study |
author |
Baratieri,Carolina |
author_facet |
Baratieri,Carolina Rocha,Roberto Campos,Caroline Menezes,Luciane Ribeiro,Gerson Luiz Ulema Ritter,Daltro Borgato,Adriano |
author_role |
author |
author2 |
Rocha,Roberto Campos,Caroline Menezes,Luciane Ribeiro,Gerson Luiz Ulema Ritter,Daltro Borgato,Adriano |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Baratieri,Carolina Rocha,Roberto Campos,Caroline Menezes,Luciane Ribeiro,Gerson Luiz Ulema Ritter,Daltro Borgato,Adriano |
dc.subject.por.fl_str_mv |
Arch shape Superelastic NiTi archwire Arch length Incisor tipping |
topic |
Arch shape Superelastic NiTi archwire Arch length Incisor tipping |
description |
OBJECTIVE: The aim of this laboratory study is to evaluate the influence of the shape and the length limitation of superelastic nickel-titanium (NiTi) archwires on lower incisors inclination during alignment and leveling. METHODS: Metal teeth mounted on a typodont articulator device were used to simulate a malocclusion of the mandibular arch (-3.5 mm model discrepancy). Three different shapes (Standard, Accuform and Ideal) of superelastic NiTi archwires (Sentalloy, GAC, USA) were tested. Specimens were divided in two groups: Group I, with no limitation of the archwire length; and Group II, with distal limitation. Each group had thirty specimens divided into three subgroups differentiated by the archwire shape. All groups used round wires with diameters of 0.014-in, 0.016-in, 0.018-in and 0.020-in. The recording of all intervals was accomplished using standardized digital photographs with orthogonal norm in relation to median sagittal plane. The buccolingual inclination of the incisor was registered using photographs and software CorelDraw. RESULTS: The results were obtained using ANOVA and Tukey's test at a significant level of 5%. The inclination of the lower incisor increased in both groups and subgroups. The shape of the archwire had statistically significant influence only in Group I - Standard (11.76º), Ideal (5.88º) and Accuform (1.93º). Analyzing the influence of the length limitation, despite the mean incisor tipping in Group II (3.91º) had been smaller than Group I (6.52º), no statistically significant difference was found, except for Standard, 3.89º with limitation and 11.76º without limitation. The greatest incisor tipping occurred with the 0.014-in archwires. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512012000300013 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512012000300013 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S2176-94512012000300013 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Dental Press International |
publisher.none.fl_str_mv |
Dental Press International |
dc.source.none.fl_str_mv |
Dental Press Journal of Orthodontics v.17 n.3 2012 reponame:Dental Press Journal of Orthodontics instname:Dental Press International (DPI) instacron:DPI |
instname_str |
Dental Press International (DPI) |
instacron_str |
DPI |
institution |
DPI |
reponame_str |
Dental Press Journal of Orthodontics |
collection |
Dental Press Journal of Orthodontics |
repository.name.fl_str_mv |
Dental Press Journal of Orthodontics - Dental Press International (DPI) |
repository.mail.fl_str_mv |
artigos@dentalpress.com.br||davidnormando@hotmail.com |
_version_ |
1754122395967291392 |