Change in crown inclination accompanying initial tooth alignment with round archwires

Detalhes bibliográficos
Autor(a) principal: MONTASSER,Mona A.
Data de Publicação: 2022
Outros Autores: KEILIG,Ludger, BOURAUEL,Christoph
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Dental Press Journal of Orthodontics
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512022000300307
Resumo: ABSTRACT Objective: To evaluate, in-vitro, the change in crown inclination that occurs during orthodontic leveling and alignment using different archwire-bracket-ligation combinations. Materials and Methods: Four archwire types were tested: (1) 0.012-in stainless steel and (2) 0.0155-in stainless steel multi-stranded, (3) 0.012-in nitinol Orthonol® and (4) 0.012-in nitinol Thermalloy®. Combinations with five types of 0.022-in slot orthodontic brackets were tested: SmartClipTM and Time3® self-ligating brackets, Mini-Taurus® and Victory SeriesTM conventional brackets, and Synergy® conventional-low friction bracket. Conventional brackets were ligated with both stainless steel and elastomeric ligatures. The simulated malocclusion comprised 2.0mm gingival and 2.0mm labial displacements of a maxillary right central incisor. Rotation around the Y-axis (representing labio-palatal inclination) was measured for the different archwire-bracket-ligation combinations. Results: The largest rotation was measured whith Orthonol® and Thermalloy® wires when combined with SmartClipTM brackets (8.07±0.24º and 8.06±0.26º, respectively) and with Synergy® brackets ligated with stainless steel ligatures (8.03±0.49º and 8.0±0.37º, respectively). The lower rotation was recorded when Thermalloy®, multi-stranded, and Orthonol® wires were ligated with elastomeric rings to Mini-Taurus® brackets (1.53±0.18º, 1.65± 0.23º and 1.70±0.28º, respectively) and to Victory SeriesTM brackets (1.68± 0.78º, 2.92± 1.40º and 1.74±0.46º, respectively). Conclusions: All archwire-bracket-ligation combinations produced lingual crown inclination; however, lower changes were observed when the conventional brackets were ligated with elastomeric rings. The multi-stranded archwire produced less rotation with nearly every bracket-ligation combination, compared to the other archwires. The effect of the archwire-bracket-ligation combination on tooth inclination during leveling and alignment should be considered during planning treatment mechanics.
id DPI-1_393fe8e59d553c5c1ad0549e05c57559
oai_identifier_str oai:scielo:S2176-94512022000300307
network_acronym_str DPI-1
network_name_str Dental Press Journal of Orthodontics
repository_id_str
spelling Change in crown inclination accompanying initial tooth alignment with round archwiresInclinationTooth alignmentOrthodontic archwiresOrthodontic bracketsABSTRACT Objective: To evaluate, in-vitro, the change in crown inclination that occurs during orthodontic leveling and alignment using different archwire-bracket-ligation combinations. Materials and Methods: Four archwire types were tested: (1) 0.012-in stainless steel and (2) 0.0155-in stainless steel multi-stranded, (3) 0.012-in nitinol Orthonol® and (4) 0.012-in nitinol Thermalloy®. Combinations with five types of 0.022-in slot orthodontic brackets were tested: SmartClipTM and Time3® self-ligating brackets, Mini-Taurus® and Victory SeriesTM conventional brackets, and Synergy® conventional-low friction bracket. Conventional brackets were ligated with both stainless steel and elastomeric ligatures. The simulated malocclusion comprised 2.0mm gingival and 2.0mm labial displacements of a maxillary right central incisor. Rotation around the Y-axis (representing labio-palatal inclination) was measured for the different archwire-bracket-ligation combinations. Results: The largest rotation was measured whith Orthonol® and Thermalloy® wires when combined with SmartClipTM brackets (8.07±0.24º and 8.06±0.26º, respectively) and with Synergy® brackets ligated with stainless steel ligatures (8.03±0.49º and 8.0±0.37º, respectively). The lower rotation was recorded when Thermalloy®, multi-stranded, and Orthonol® wires were ligated with elastomeric rings to Mini-Taurus® brackets (1.53±0.18º, 1.65± 0.23º and 1.70±0.28º, respectively) and to Victory SeriesTM brackets (1.68± 0.78º, 2.92± 1.40º and 1.74±0.46º, respectively). Conclusions: All archwire-bracket-ligation combinations produced lingual crown inclination; however, lower changes were observed when the conventional brackets were ligated with elastomeric rings. The multi-stranded archwire produced less rotation with nearly every bracket-ligation combination, compared to the other archwires. The effect of the archwire-bracket-ligation combination on tooth inclination during leveling and alignment should be considered during planning treatment mechanics.Dental Press International2022-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512022000300307Dental Press Journal of Orthodontics v.27 n.3 2022reponame:Dental Press Journal of Orthodonticsinstname:Dental Press International (DPI)instacron:DPI10.1590/2177-6709.27.3.e2220489.oarinfo:eu-repo/semantics/openAccessMONTASSER,Mona A.KEILIG,LudgerBOURAUEL,Christopheng2022-07-01T00:00:00Zoai:scielo:S2176-94512022000300307Revistahttp://www.scielo.br/dpjoONGhttps://old.scielo.br/oai/scielo-oai.phpartigos@dentalpress.com.br||davidnormando@hotmail.com2177-67092176-9451opendoar:2022-07-01T00:00Dental Press Journal of Orthodontics - Dental Press International (DPI)false
dc.title.none.fl_str_mv Change in crown inclination accompanying initial tooth alignment with round archwires
title Change in crown inclination accompanying initial tooth alignment with round archwires
spellingShingle Change in crown inclination accompanying initial tooth alignment with round archwires
MONTASSER,Mona A.
Inclination
Tooth alignment
Orthodontic archwires
Orthodontic brackets
title_short Change in crown inclination accompanying initial tooth alignment with round archwires
title_full Change in crown inclination accompanying initial tooth alignment with round archwires
title_fullStr Change in crown inclination accompanying initial tooth alignment with round archwires
title_full_unstemmed Change in crown inclination accompanying initial tooth alignment with round archwires
title_sort Change in crown inclination accompanying initial tooth alignment with round archwires
author MONTASSER,Mona A.
author_facet MONTASSER,Mona A.
KEILIG,Ludger
BOURAUEL,Christoph
author_role author
author2 KEILIG,Ludger
BOURAUEL,Christoph
author2_role author
author
dc.contributor.author.fl_str_mv MONTASSER,Mona A.
KEILIG,Ludger
BOURAUEL,Christoph
dc.subject.por.fl_str_mv Inclination
Tooth alignment
Orthodontic archwires
Orthodontic brackets
topic Inclination
Tooth alignment
Orthodontic archwires
Orthodontic brackets
description ABSTRACT Objective: To evaluate, in-vitro, the change in crown inclination that occurs during orthodontic leveling and alignment using different archwire-bracket-ligation combinations. Materials and Methods: Four archwire types were tested: (1) 0.012-in stainless steel and (2) 0.0155-in stainless steel multi-stranded, (3) 0.012-in nitinol Orthonol® and (4) 0.012-in nitinol Thermalloy®. Combinations with five types of 0.022-in slot orthodontic brackets were tested: SmartClipTM and Time3® self-ligating brackets, Mini-Taurus® and Victory SeriesTM conventional brackets, and Synergy® conventional-low friction bracket. Conventional brackets were ligated with both stainless steel and elastomeric ligatures. The simulated malocclusion comprised 2.0mm gingival and 2.0mm labial displacements of a maxillary right central incisor. Rotation around the Y-axis (representing labio-palatal inclination) was measured for the different archwire-bracket-ligation combinations. Results: The largest rotation was measured whith Orthonol® and Thermalloy® wires when combined with SmartClipTM brackets (8.07±0.24º and 8.06±0.26º, respectively) and with Synergy® brackets ligated with stainless steel ligatures (8.03±0.49º and 8.0±0.37º, respectively). The lower rotation was recorded when Thermalloy®, multi-stranded, and Orthonol® wires were ligated with elastomeric rings to Mini-Taurus® brackets (1.53±0.18º, 1.65± 0.23º and 1.70±0.28º, respectively) and to Victory SeriesTM brackets (1.68± 0.78º, 2.92± 1.40º and 1.74±0.46º, respectively). Conclusions: All archwire-bracket-ligation combinations produced lingual crown inclination; however, lower changes were observed when the conventional brackets were ligated with elastomeric rings. The multi-stranded archwire produced less rotation with nearly every bracket-ligation combination, compared to the other archwires. The effect of the archwire-bracket-ligation combination on tooth inclination during leveling and alignment should be considered during planning treatment mechanics.
publishDate 2022
dc.date.none.fl_str_mv 2022-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512022000300307
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512022000300307
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/2177-6709.27.3.e2220489.oar
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Dental Press International
publisher.none.fl_str_mv Dental Press International
dc.source.none.fl_str_mv Dental Press Journal of Orthodontics v.27 n.3 2022
reponame:Dental Press Journal of Orthodontics
instname:Dental Press International (DPI)
instacron:DPI
instname_str Dental Press International (DPI)
instacron_str DPI
institution DPI
reponame_str Dental Press Journal of Orthodontics
collection Dental Press Journal of Orthodontics
repository.name.fl_str_mv Dental Press Journal of Orthodontics - Dental Press International (DPI)
repository.mail.fl_str_mv artigos@dentalpress.com.br||davidnormando@hotmail.com
_version_ 1754122399139233792