Assessment of the dimensions and surface characteristics of orthodontic wires and bracket slots

Detalhes bibliográficos
Autor(a) principal: Dolci,Gabriel Schmidt
Data de Publicação: 2013
Outros Autores: Spohr,Ana Maria, Zimmer,Eduardo Rigon, Marchioro,Ernani Menezes
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Dental Press Journal of Orthodontics
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512013000200016
Resumo: OBJECTIVE: The purpose of this study was to evaluate the dimensions and surface characteristics of orthodontic wires and bracket slots of different commercial brands. METHODS: Thirty metallic brackets (0.022 x 0.028-in and 0.022 x 0.030-in) were divided in three groups: DYN/3M group = Dyna-Lock, 3M/Unitek (stainless steel, or SS); STD/MO group = Slim Morelli (SS); and Ni-Free/MO group = Slim Morelli (Ni-Free). The stainless steel wires (0.019 x 0.025in) were divided into two groups: MO group = Morelli; and 3M group = 3M/Unitek. The bracket and wire measurements were done by two methods: (a) Surface Electron Microscopy (SEM), and (b) Profile projection. The surface analysis was done qualitatively, based on SEM images and/or by a rugosimeter. The quantitative results were analyzed by ANOVA with Tukey's test (p < 0.05) and Student's t test. RESULTS: A significant difference in the dimensions of slots was observed, and the NiFree/MO group showed the greatest changes when compared to the other groups. The analysis of surface topography of the brackets indicated greater homogeneity of the metallic matrix for DYN/3M and STD/MO groups. As for the dimensions of the wires, groups showed statistically different mean heights. CONCLUSIONS: It was concluded that wires and brackets slots can present altered dimensions, which might directly and unintentionally affect the planned tooth movement.
id DPI-1_e3e0f52ee07d1f8d1f66ba9aee96b960
oai_identifier_str oai:scielo:S2176-94512013000200016
network_acronym_str DPI-1
network_name_str Dental Press Journal of Orthodontics
repository_id_str
spelling Assessment of the dimensions and surface characteristics of orthodontic wires and bracket slotsOrthodontic bracketsOrthodontic wiresFrictionOBJECTIVE: The purpose of this study was to evaluate the dimensions and surface characteristics of orthodontic wires and bracket slots of different commercial brands. METHODS: Thirty metallic brackets (0.022 x 0.028-in and 0.022 x 0.030-in) were divided in three groups: DYN/3M group = Dyna-Lock, 3M/Unitek (stainless steel, or SS); STD/MO group = Slim Morelli (SS); and Ni-Free/MO group = Slim Morelli (Ni-Free). The stainless steel wires (0.019 x 0.025in) were divided into two groups: MO group = Morelli; and 3M group = 3M/Unitek. The bracket and wire measurements were done by two methods: (a) Surface Electron Microscopy (SEM), and (b) Profile projection. The surface analysis was done qualitatively, based on SEM images and/or by a rugosimeter. The quantitative results were analyzed by ANOVA with Tukey's test (p < 0.05) and Student's t test. RESULTS: A significant difference in the dimensions of slots was observed, and the NiFree/MO group showed the greatest changes when compared to the other groups. The analysis of surface topography of the brackets indicated greater homogeneity of the metallic matrix for DYN/3M and STD/MO groups. As for the dimensions of the wires, groups showed statistically different mean heights. CONCLUSIONS: It was concluded that wires and brackets slots can present altered dimensions, which might directly and unintentionally affect the planned tooth movement.Dental Press International2013-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512013000200016Dental Press Journal of Orthodontics v.18 n.2 2013reponame:Dental Press Journal of Orthodonticsinstname:Dental Press International (DPI)instacron:DPI10.1590/S2176-94512013000200016info:eu-repo/semantics/openAccessDolci,Gabriel SchmidtSpohr,Ana MariaZimmer,Eduardo RigonMarchioro,Ernani Menezeseng2013-08-16T00:00:00Zoai:scielo:S2176-94512013000200016Revistahttp://www.scielo.br/dpjoONGhttps://old.scielo.br/oai/scielo-oai.phpartigos@dentalpress.com.br||davidnormando@hotmail.com2177-67092176-9451opendoar:2013-08-16T00:00Dental Press Journal of Orthodontics - Dental Press International (DPI)false
dc.title.none.fl_str_mv Assessment of the dimensions and surface characteristics of orthodontic wires and bracket slots
title Assessment of the dimensions and surface characteristics of orthodontic wires and bracket slots
spellingShingle Assessment of the dimensions and surface characteristics of orthodontic wires and bracket slots
Dolci,Gabriel Schmidt
Orthodontic brackets
Orthodontic wires
Friction
title_short Assessment of the dimensions and surface characteristics of orthodontic wires and bracket slots
title_full Assessment of the dimensions and surface characteristics of orthodontic wires and bracket slots
title_fullStr Assessment of the dimensions and surface characteristics of orthodontic wires and bracket slots
title_full_unstemmed Assessment of the dimensions and surface characteristics of orthodontic wires and bracket slots
title_sort Assessment of the dimensions and surface characteristics of orthodontic wires and bracket slots
author Dolci,Gabriel Schmidt
author_facet Dolci,Gabriel Schmidt
Spohr,Ana Maria
Zimmer,Eduardo Rigon
Marchioro,Ernani Menezes
author_role author
author2 Spohr,Ana Maria
Zimmer,Eduardo Rigon
Marchioro,Ernani Menezes
author2_role author
author
author
dc.contributor.author.fl_str_mv Dolci,Gabriel Schmidt
Spohr,Ana Maria
Zimmer,Eduardo Rigon
Marchioro,Ernani Menezes
dc.subject.por.fl_str_mv Orthodontic brackets
Orthodontic wires
Friction
topic Orthodontic brackets
Orthodontic wires
Friction
description OBJECTIVE: The purpose of this study was to evaluate the dimensions and surface characteristics of orthodontic wires and bracket slots of different commercial brands. METHODS: Thirty metallic brackets (0.022 x 0.028-in and 0.022 x 0.030-in) were divided in three groups: DYN/3M group = Dyna-Lock, 3M/Unitek (stainless steel, or SS); STD/MO group = Slim Morelli (SS); and Ni-Free/MO group = Slim Morelli (Ni-Free). The stainless steel wires (0.019 x 0.025in) were divided into two groups: MO group = Morelli; and 3M group = 3M/Unitek. The bracket and wire measurements were done by two methods: (a) Surface Electron Microscopy (SEM), and (b) Profile projection. The surface analysis was done qualitatively, based on SEM images and/or by a rugosimeter. The quantitative results were analyzed by ANOVA with Tukey's test (p < 0.05) and Student's t test. RESULTS: A significant difference in the dimensions of slots was observed, and the NiFree/MO group showed the greatest changes when compared to the other groups. The analysis of surface topography of the brackets indicated greater homogeneity of the metallic matrix for DYN/3M and STD/MO groups. As for the dimensions of the wires, groups showed statistically different mean heights. CONCLUSIONS: It was concluded that wires and brackets slots can present altered dimensions, which might directly and unintentionally affect the planned tooth movement.
publishDate 2013
dc.date.none.fl_str_mv 2013-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512013000200016
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512013000200016
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S2176-94512013000200016
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Dental Press International
publisher.none.fl_str_mv Dental Press International
dc.source.none.fl_str_mv Dental Press Journal of Orthodontics v.18 n.2 2013
reponame:Dental Press Journal of Orthodontics
instname:Dental Press International (DPI)
instacron:DPI
instname_str Dental Press International (DPI)
instacron_str DPI
institution DPI
reponame_str Dental Press Journal of Orthodontics
collection Dental Press Journal of Orthodontics
repository.name.fl_str_mv Dental Press Journal of Orthodontics - Dental Press International (DPI)
repository.mail.fl_str_mv artigos@dentalpress.com.br||davidnormando@hotmail.com
_version_ 1754122396413984768