Resumo: | INTRODUCTION: Fixed orthodontic appliances have been regarded as a common causative factor of oral lesions. To manage soft tissue discomfort, most orthodontists recommend using a small amount of utility wax over the brackets in order to alleviate trauma. This in vitro study aimed at evaluating friction generated by two types of bracket protectors (customized acetate protector [CAP] and temporary resin protector [TRP]) during the initial stages of orthodontic treatment. METHODS: An experimental model (test unit) was used to assess friction. In order to measure the friction produced in each test, the model was attached to a mechanical testing machine which simulated maxillary canines alignment. Intergroup comparison was carried out by one-way ANOVA with level of significance set at 5%. RESULTS: The friction presented by the TRP group was statistically higher than that of the control group at 6 mm. It was also higher than in the control and CAP groups in terms of maximum friction. CONCLUSION: The customized acetate protector (CAP) demonstrated not to interfere in friction between the wire and the orthodontic bracket slot. |
id |
DPI-1_ec099d278ece5d4dc4746f8b044d4dc9 |
---|---|
oai_identifier_str |
oai:scielo:S2176-94512014000100086 |
network_acronym_str |
DPI-1 |
network_name_str |
Dental Press Journal of Orthodontics |
repository_id_str |
|
spelling |
Comparison of friction produced by two types of orthodontic bracket protectorsOrthodonticsOrthodontic bracketsFriction INTRODUCTION: Fixed orthodontic appliances have been regarded as a common causative factor of oral lesions. To manage soft tissue discomfort, most orthodontists recommend using a small amount of utility wax over the brackets in order to alleviate trauma. This in vitro study aimed at evaluating friction generated by two types of bracket protectors (customized acetate protector [CAP] and temporary resin protector [TRP]) during the initial stages of orthodontic treatment. METHODS: An experimental model (test unit) was used to assess friction. In order to measure the friction produced in each test, the model was attached to a mechanical testing machine which simulated maxillary canines alignment. Intergroup comparison was carried out by one-way ANOVA with level of significance set at 5%. RESULTS: The friction presented by the TRP group was statistically higher than that of the control group at 6 mm. It was also higher than in the control and CAP groups in terms of maximum friction. CONCLUSION: The customized acetate protector (CAP) demonstrated not to interfere in friction between the wire and the orthodontic bracket slot. Dental Press International2014-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512014000100086Dental Press Journal of Orthodontics v.19 n.1 2014reponame:Dental Press Journal of Orthodonticsinstname:Dental Press International (DPI)instacron:DPI10.1590/2176-9451.19.1.086-091.oarinfo:eu-repo/semantics/openAccessMendonça,Steyner de LimaPraxedes Neto,Otávio JoséOliveira,Patricia Teixeira deSantos,Patricia Bittencourt Dutra dosPinheiro,Fábio Henrique de Sá Leitãoeng2015-08-21T00:00:00Zoai:scielo:S2176-94512014000100086Revistahttp://www.scielo.br/dpjoONGhttps://old.scielo.br/oai/scielo-oai.phpartigos@dentalpress.com.br||davidnormando@hotmail.com2177-67092176-9451opendoar:2015-08-21T00:00Dental Press Journal of Orthodontics - Dental Press International (DPI)false |
dc.title.none.fl_str_mv |
Comparison of friction produced by two types of orthodontic bracket protectors |
title |
Comparison of friction produced by two types of orthodontic bracket protectors |
spellingShingle |
Comparison of friction produced by two types of orthodontic bracket protectors Mendonça,Steyner de Lima Orthodontics Orthodontic brackets Friction |
title_short |
Comparison of friction produced by two types of orthodontic bracket protectors |
title_full |
Comparison of friction produced by two types of orthodontic bracket protectors |
title_fullStr |
Comparison of friction produced by two types of orthodontic bracket protectors |
title_full_unstemmed |
Comparison of friction produced by two types of orthodontic bracket protectors |
title_sort |
Comparison of friction produced by two types of orthodontic bracket protectors |
author |
Mendonça,Steyner de Lima |
author_facet |
Mendonça,Steyner de Lima Praxedes Neto,Otávio José Oliveira,Patricia Teixeira de Santos,Patricia Bittencourt Dutra dos Pinheiro,Fábio Henrique de Sá Leitão |
author_role |
author |
author2 |
Praxedes Neto,Otávio José Oliveira,Patricia Teixeira de Santos,Patricia Bittencourt Dutra dos Pinheiro,Fábio Henrique de Sá Leitão |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Mendonça,Steyner de Lima Praxedes Neto,Otávio José Oliveira,Patricia Teixeira de Santos,Patricia Bittencourt Dutra dos Pinheiro,Fábio Henrique de Sá Leitão |
dc.subject.por.fl_str_mv |
Orthodontics Orthodontic brackets Friction |
topic |
Orthodontics Orthodontic brackets Friction |
description |
INTRODUCTION: Fixed orthodontic appliances have been regarded as a common causative factor of oral lesions. To manage soft tissue discomfort, most orthodontists recommend using a small amount of utility wax over the brackets in order to alleviate trauma. This in vitro study aimed at evaluating friction generated by two types of bracket protectors (customized acetate protector [CAP] and temporary resin protector [TRP]) during the initial stages of orthodontic treatment. METHODS: An experimental model (test unit) was used to assess friction. In order to measure the friction produced in each test, the model was attached to a mechanical testing machine which simulated maxillary canines alignment. Intergroup comparison was carried out by one-way ANOVA with level of significance set at 5%. RESULTS: The friction presented by the TRP group was statistically higher than that of the control group at 6 mm. It was also higher than in the control and CAP groups in terms of maximum friction. CONCLUSION: The customized acetate protector (CAP) demonstrated not to interfere in friction between the wire and the orthodontic bracket slot. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-02-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512014000100086 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512014000100086 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/2176-9451.19.1.086-091.oar |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Dental Press International |
publisher.none.fl_str_mv |
Dental Press International |
dc.source.none.fl_str_mv |
Dental Press Journal of Orthodontics v.19 n.1 2014 reponame:Dental Press Journal of Orthodontics instname:Dental Press International (DPI) instacron:DPI |
instname_str |
Dental Press International (DPI) |
instacron_str |
DPI |
institution |
DPI |
reponame_str |
Dental Press Journal of Orthodontics |
collection |
Dental Press Journal of Orthodontics |
repository.name.fl_str_mv |
Dental Press Journal of Orthodontics - Dental Press International (DPI) |
repository.mail.fl_str_mv |
artigos@dentalpress.com.br||davidnormando@hotmail.com |
_version_ |
1754122396820832256 |