Volume distribution pattern of spray nozzles (JD14-2)

Detalhes bibliográficos
Autor(a) principal: Galli, Julio Cesar
Data de Publicação: 2014
Outros Autores: Arruda, Antonio Carlos de
Tipo de documento: Artigo
Idioma: por
Título da fonte: Pesquisa Agropecuária Brasileira (Online)
Texto Completo: https://seer.sct.embrapa.br/index.php/pab/article/view/16315
Resumo: The present research work conducted at Faculdade de Ciências Agrárias e Veterinárias da UNESP, "Campus" de Jaboticabal, São Paulo, Brazil, had as main objective the study of some parameters related to the quality of different spray nozzles such as: distribution pattern and liquid output. For the trial, pulverizing device with adjustable pressure, height and time spraying was built, which works in conjunction with the nozzle patternator made according to the World Health Organization specifications. Forty nozzles were tested under standardized conditions of pressure (40 PSI), spraying time (1 minute) and height (30 cm). The liquid discharge rate of each nozzle was compared with the liquid throughput specified by the manufacturer (or with the nozzle denominations code) and the volumetric distribution were presented graphically. The nozzles JD14-2 exhibited great uniformity of throughput between the replications (40 PSI). However, a significant deviation in the distribution pattern was detected. The difference suggests lack of standardization of the manufacturing process or poor control of the quality by the manufacturers.
id EMBRAPA-4_13640ae11d9ebca07974c45a9c5f308e
oai_identifier_str oai:ojs.seer.sct.embrapa.br:article/16315
network_acronym_str EMBRAPA-4
network_name_str Pesquisa Agropecuária Brasileira (Online)
repository_id_str
spelling Volume distribution pattern of spray nozzles (JD14-2)Distribuição volumétrica dos bicos pulverizadores JD14-2spray coverage; liquid discharge uniformityfaixa de deposição; uniformidade de vazãoThe present research work conducted at Faculdade de Ciências Agrárias e Veterinárias da UNESP, "Campus" de Jaboticabal, São Paulo, Brazil, had as main objective the study of some parameters related to the quality of different spray nozzles such as: distribution pattern and liquid output. For the trial, pulverizing device with adjustable pressure, height and time spraying was built, which works in conjunction with the nozzle patternator made according to the World Health Organization specifications. Forty nozzles were tested under standardized conditions of pressure (40 PSI), spraying time (1 minute) and height (30 cm). The liquid discharge rate of each nozzle was compared with the liquid throughput specified by the manufacturer (or with the nozzle denominations code) and the volumetric distribution were presented graphically. The nozzles JD14-2 exhibited great uniformity of throughput between the replications (40 PSI). However, a significant deviation in the distribution pattern was detected. The difference suggests lack of standardization of the manufacturing process or poor control of the quality by the manufacturers.O trabalho foi realizado no Departamento de Entomologia e Nematologia da Faculdade de Ciências Agrárias e Veterinárias, "Campus" de Jaboticabal da UNESP, e teve como objetivo estudar alguns parâmetros relacionados com a qualidade de bicos pulverizadores, tais como padrão de distribuição volumétrica e variação de vazão. Para os ensaios, foi empregado um equipamento pulverizador, com pressão de trabalho, altura e tempo de pulverização reguláveis, que funciona sobre uma mesa de distribuição volumétrica construída segundo as especificações da Organização Mundial de Saúde. Quarenta exemplares de bicos JD14-2 foram testados, padronizando-se, entre repetições, a pressão de trabalho (40 lb/pol2 ), o tempo de pulverização (1 minuto) e a altura (30 cm). A vazão de cada bico foi comparada com a vazão estipulada pelo fabricante (ou com o código de denominação do bico), e as distribuições volumétricas foram relacionadas em gráficos. Os bicos pulverizadores JD14-2 mostraram pouca variação de vazão na pressão de 40 lb/pol2. Entretanto, diferiram consideravelmente com relação ao padrão de distribuição volumétrica, sugerindo falta de padronização do processo de fabricação ou falhas no controle de qualidade.Pesquisa Agropecuaria BrasileiraPesquisa Agropecuária BrasileiraGalli, Julio CesarArruda, Antonio Carlos de2014-04-16info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://seer.sct.embrapa.br/index.php/pab/article/view/16315Pesquisa Agropecuaria Brasileira; v.20, n.11, nov. 1985; 1239-1244Pesquisa Agropecuária Brasileira; v.20, n.11, nov. 1985; 1239-12441678-39210100-104xreponame:Pesquisa Agropecuária Brasileira (Online)instname:Empresa Brasileira de Pesquisa Agropecuária (Embrapa)instacron:EMBRAPAporhttps://seer.sct.embrapa.br/index.php/pab/article/view/16315/10524info:eu-repo/semantics/openAccess2014-04-16T19:38:10Zoai:ojs.seer.sct.embrapa.br:article/16315Revistahttp://seer.sct.embrapa.br/index.php/pabPRIhttps://old.scielo.br/oai/scielo-oai.phppab@sct.embrapa.br || sct.pab@embrapa.br1678-39210100-204Xopendoar:2014-04-16T19:38:10Pesquisa Agropecuária Brasileira (Online) - Empresa Brasileira de Pesquisa Agropecuária (Embrapa)false
dc.title.none.fl_str_mv Volume distribution pattern of spray nozzles (JD14-2)
Distribuição volumétrica dos bicos pulverizadores JD14-2
title Volume distribution pattern of spray nozzles (JD14-2)
spellingShingle Volume distribution pattern of spray nozzles (JD14-2)
Galli, Julio Cesar
spray coverage; liquid discharge uniformity
faixa de deposição; uniformidade de vazão
title_short Volume distribution pattern of spray nozzles (JD14-2)
title_full Volume distribution pattern of spray nozzles (JD14-2)
title_fullStr Volume distribution pattern of spray nozzles (JD14-2)
title_full_unstemmed Volume distribution pattern of spray nozzles (JD14-2)
title_sort Volume distribution pattern of spray nozzles (JD14-2)
author Galli, Julio Cesar
author_facet Galli, Julio Cesar
Arruda, Antonio Carlos de
author_role author
author2 Arruda, Antonio Carlos de
author2_role author
dc.contributor.none.fl_str_mv

dc.contributor.author.fl_str_mv Galli, Julio Cesar
Arruda, Antonio Carlos de
dc.subject.por.fl_str_mv spray coverage; liquid discharge uniformity
faixa de deposição; uniformidade de vazão
topic spray coverage; liquid discharge uniformity
faixa de deposição; uniformidade de vazão
description The present research work conducted at Faculdade de Ciências Agrárias e Veterinárias da UNESP, "Campus" de Jaboticabal, São Paulo, Brazil, had as main objective the study of some parameters related to the quality of different spray nozzles such as: distribution pattern and liquid output. For the trial, pulverizing device with adjustable pressure, height and time spraying was built, which works in conjunction with the nozzle patternator made according to the World Health Organization specifications. Forty nozzles were tested under standardized conditions of pressure (40 PSI), spraying time (1 minute) and height (30 cm). The liquid discharge rate of each nozzle was compared with the liquid throughput specified by the manufacturer (or with the nozzle denominations code) and the volumetric distribution were presented graphically. The nozzles JD14-2 exhibited great uniformity of throughput between the replications (40 PSI). However, a significant deviation in the distribution pattern was detected. The difference suggests lack of standardization of the manufacturing process or poor control of the quality by the manufacturers.
publishDate 2014
dc.date.none.fl_str_mv 2014-04-16
dc.type.none.fl_str_mv
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://seer.sct.embrapa.br/index.php/pab/article/view/16315
url https://seer.sct.embrapa.br/index.php/pab/article/view/16315
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://seer.sct.embrapa.br/index.php/pab/article/view/16315/10524
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Pesquisa Agropecuaria Brasileira
Pesquisa Agropecuária Brasileira
publisher.none.fl_str_mv Pesquisa Agropecuaria Brasileira
Pesquisa Agropecuária Brasileira
dc.source.none.fl_str_mv Pesquisa Agropecuaria Brasileira; v.20, n.11, nov. 1985; 1239-1244
Pesquisa Agropecuária Brasileira; v.20, n.11, nov. 1985; 1239-1244
1678-3921
0100-104x
reponame:Pesquisa Agropecuária Brasileira (Online)
instname:Empresa Brasileira de Pesquisa Agropecuária (Embrapa)
instacron:EMBRAPA
instname_str Empresa Brasileira de Pesquisa Agropecuária (Embrapa)
instacron_str EMBRAPA
institution EMBRAPA
reponame_str Pesquisa Agropecuária Brasileira (Online)
collection Pesquisa Agropecuária Brasileira (Online)
repository.name.fl_str_mv Pesquisa Agropecuária Brasileira (Online) - Empresa Brasileira de Pesquisa Agropecuária (Embrapa)
repository.mail.fl_str_mv pab@sct.embrapa.br || sct.pab@embrapa.br
_version_ 1793416693976924160