Thermal processes for lead removal from the funnel glass of CRT monitors
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | REM. Revista Escola de Minas (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0370-44672015000300287 |
Resumo: | The disposal of CRT monitors increases each year, generating millions of tons of waste containing various types of materials. The glass present in CRT tubes displayed about 20%-25% of lead oxide. If improperly disposed of, this glass can be leached directly in nature or may cause environmental contamination, especially with lead. Because of this leaching possibility, this waste is classified as Class I solid waste, according to the NBR 10004. Thermal processing of these glass tubes was seen as an alternative to remove lead from the glass matrix. Parameters such as reaction time, percentage of reducing agent, the reaction temperature, and atmospheric environment of the system were analyzed in this work. It was concluded that it is possible to remove the lead from the glass matrix by thermal processing. The removal of 92% of the lead from the glass was obtained at 800°C, a vacuum of 1.3 kPa, with 5% carbon as a reducing agent, and 18 hours of thermal processing. |
id |
ESCOLADEMINAS-1_87fd96b4408dc017309cafdfe267cdf0 |
---|---|
oai_identifier_str |
oai:scielo:S0370-44672015000300287 |
network_acronym_str |
ESCOLADEMINAS-1 |
network_name_str |
REM. Revista Escola de Minas (Online) |
repository_id_str |
|
spelling |
Thermal processes for lead removal from the funnel glass of CRT monitorslead removalCRT monitorselectrical waste and electronic equipmentThe disposal of CRT monitors increases each year, generating millions of tons of waste containing various types of materials. The glass present in CRT tubes displayed about 20%-25% of lead oxide. If improperly disposed of, this glass can be leached directly in nature or may cause environmental contamination, especially with lead. Because of this leaching possibility, this waste is classified as Class I solid waste, according to the NBR 10004. Thermal processing of these glass tubes was seen as an alternative to remove lead from the glass matrix. Parameters such as reaction time, percentage of reducing agent, the reaction temperature, and atmospheric environment of the system were analyzed in this work. It was concluded that it is possible to remove the lead from the glass matrix by thermal processing. The removal of 92% of the lead from the glass was obtained at 800°C, a vacuum of 1.3 kPa, with 5% carbon as a reducing agent, and 18 hours of thermal processing.Escola de Minas2015-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0370-44672015000300287Rem: Revista Escola de Minas v.68 n.3 2015reponame:REM. Revista Escola de Minas (Online)instname:Escola de Minasinstacron:ESCOLA DE MINAS10.1590/0370-44672014680141info:eu-repo/semantics/openAccessVeit,Hugo MarceloOliveira,Erich deRichter,Guilhermeeng2015-09-02T00:00:00Zoai:scielo:S0370-44672015000300287Revistahttp://www.scielo.br/remhttps://old.scielo.br/oai/scielo-oai.phpeditor@rem.com.br1807-03530370-4467opendoar:2015-09-02T00:00REM. Revista Escola de Minas (Online) - Escola de Minasfalse |
dc.title.none.fl_str_mv |
Thermal processes for lead removal from the funnel glass of CRT monitors |
title |
Thermal processes for lead removal from the funnel glass of CRT monitors |
spellingShingle |
Thermal processes for lead removal from the funnel glass of CRT monitors Veit,Hugo Marcelo lead removal CRT monitors electrical waste and electronic equipment |
title_short |
Thermal processes for lead removal from the funnel glass of CRT monitors |
title_full |
Thermal processes for lead removal from the funnel glass of CRT monitors |
title_fullStr |
Thermal processes for lead removal from the funnel glass of CRT monitors |
title_full_unstemmed |
Thermal processes for lead removal from the funnel glass of CRT monitors |
title_sort |
Thermal processes for lead removal from the funnel glass of CRT monitors |
author |
Veit,Hugo Marcelo |
author_facet |
Veit,Hugo Marcelo Oliveira,Erich de Richter,Guilherme |
author_role |
author |
author2 |
Oliveira,Erich de Richter,Guilherme |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Veit,Hugo Marcelo Oliveira,Erich de Richter,Guilherme |
dc.subject.por.fl_str_mv |
lead removal CRT monitors electrical waste and electronic equipment |
topic |
lead removal CRT monitors electrical waste and electronic equipment |
description |
The disposal of CRT monitors increases each year, generating millions of tons of waste containing various types of materials. The glass present in CRT tubes displayed about 20%-25% of lead oxide. If improperly disposed of, this glass can be leached directly in nature or may cause environmental contamination, especially with lead. Because of this leaching possibility, this waste is classified as Class I solid waste, according to the NBR 10004. Thermal processing of these glass tubes was seen as an alternative to remove lead from the glass matrix. Parameters such as reaction time, percentage of reducing agent, the reaction temperature, and atmospheric environment of the system were analyzed in this work. It was concluded that it is possible to remove the lead from the glass matrix by thermal processing. The removal of 92% of the lead from the glass was obtained at 800°C, a vacuum of 1.3 kPa, with 5% carbon as a reducing agent, and 18 hours of thermal processing. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-09-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0370-44672015000300287 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0370-44672015000300287 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/0370-44672014680141 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Escola de Minas |
publisher.none.fl_str_mv |
Escola de Minas |
dc.source.none.fl_str_mv |
Rem: Revista Escola de Minas v.68 n.3 2015 reponame:REM. Revista Escola de Minas (Online) instname:Escola de Minas instacron:ESCOLA DE MINAS |
instname_str |
Escola de Minas |
instacron_str |
ESCOLA DE MINAS |
institution |
ESCOLA DE MINAS |
reponame_str |
REM. Revista Escola de Minas (Online) |
collection |
REM. Revista Escola de Minas (Online) |
repository.name.fl_str_mv |
REM. Revista Escola de Minas (Online) - Escola de Minas |
repository.mail.fl_str_mv |
editor@rem.com.br |
_version_ |
1754122199020601344 |