Immunogenicity test of tetanus component in adsorbed vaccines by toxin binding inhibition test
Autor(a) principal: | |
---|---|
Data de Publicação: | 2002 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Memórias do Instituto Oswaldo Cruz |
Texto Completo: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02762002000600030 |
Resumo: | Samples from 20 lots of diphtheria-tetanus (adult use dT) vaccine and from 20 lots of diphtheria-tetanus-pertussis (DTP) vaccine were used to standardize and validate the in vitro toxin binding inhibition (ToBI) test for the immunogenicity test of the tetanus component. The levels of tetanus antitoxin obtained by ToBI test were compared to those obtained using the toxin neutralization (TN) test in mice routinely employed to perform the quality control of the tetanus component in adsorbed vaccines. The results ranged from 1.8 to 3.5 IU/ml for dT and 2 to 4 IU/ml for DTP by ToBI test and 1.4 to 3 IU/ml for dT and 1.8 to 3.5 IU/ml for DTP by TN in mice. These results were significantly correlated. From this study, it is concluded that the ToBI test is an alternative to the in vivo neutralization procedure in the immunogenicity test of the tetanus component in adsorbed vaccines. A substantial refinement and a reduction in use of animals can be achieved. |
id |
FIOCRUZ-4_47229e90cb3b5eb35c97c53970e6fe6d |
---|---|
oai_identifier_str |
oai:scielo:S0074-02762002000600030 |
network_acronym_str |
FIOCRUZ-4 |
network_name_str |
Memórias do Instituto Oswaldo Cruz |
spelling |
Immunogenicity test of tetanus component in adsorbed vaccines by toxin binding inhibition testdiphtheria-tetanus vaccinediphtheria-tetanus-pertussis vaccinetoxin binding inhibition testtetanusquality controlseroneutralizationSamples from 20 lots of diphtheria-tetanus (adult use dT) vaccine and from 20 lots of diphtheria-tetanus-pertussis (DTP) vaccine were used to standardize and validate the in vitro toxin binding inhibition (ToBI) test for the immunogenicity test of the tetanus component. The levels of tetanus antitoxin obtained by ToBI test were compared to those obtained using the toxin neutralization (TN) test in mice routinely employed to perform the quality control of the tetanus component in adsorbed vaccines. The results ranged from 1.8 to 3.5 IU/ml for dT and 2 to 4 IU/ml for DTP by ToBI test and 1.4 to 3 IU/ml for dT and 1.8 to 3.5 IU/ml for DTP by TN in mice. These results were significantly correlated. From this study, it is concluded that the ToBI test is an alternative to the in vivo neutralization procedure in the immunogenicity test of the tetanus component in adsorbed vaccines. A substantial refinement and a reduction in use of animals can be achieved.Instituto Oswaldo Cruz, Ministério da Saúde2002-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02762002000600030Memórias do Instituto Oswaldo Cruz v.97 n.6 2002reponame:Memórias do Instituto Oswaldo Cruzinstname:Fundação Oswaldo Cruzinstacron:FIOCRUZ10.1590/S0074-02762002000600030info:eu-repo/semantics/openAccessMatos,Denise Cristina SouzaMarcovistz,RugimarCabello,Pedro HernanGeorgini,Ricardo AmaralSakauchi,DirceSilva,Luciana Leite daeng2020-04-25T17:48:51Zhttp://www.scielo.br/oai/scielo-oai.php0074-02761678-8060opendoar:null2020-04-26 02:11:22.994Memórias do Instituto Oswaldo Cruz - Fundação Oswaldo Cruztrue |
dc.title.none.fl_str_mv |
Immunogenicity test of tetanus component in adsorbed vaccines by toxin binding inhibition test |
title |
Immunogenicity test of tetanus component in adsorbed vaccines by toxin binding inhibition test |
spellingShingle |
Immunogenicity test of tetanus component in adsorbed vaccines by toxin binding inhibition test Matos,Denise Cristina Souza diphtheria-tetanus vaccine diphtheria-tetanus-pertussis vaccine toxin binding inhibition test tetanus quality control seroneutralization |
title_short |
Immunogenicity test of tetanus component in adsorbed vaccines by toxin binding inhibition test |
title_full |
Immunogenicity test of tetanus component in adsorbed vaccines by toxin binding inhibition test |
title_fullStr |
Immunogenicity test of tetanus component in adsorbed vaccines by toxin binding inhibition test |
title_full_unstemmed |
Immunogenicity test of tetanus component in adsorbed vaccines by toxin binding inhibition test |
title_sort |
Immunogenicity test of tetanus component in adsorbed vaccines by toxin binding inhibition test |
author |
Matos,Denise Cristina Souza |
author_facet |
Matos,Denise Cristina Souza Marcovistz,Rugimar Cabello,Pedro Hernan Georgini,Ricardo Amaral Sakauchi,Dirce Silva,Luciana Leite da |
author_role |
author |
author2 |
Marcovistz,Rugimar Cabello,Pedro Hernan Georgini,Ricardo Amaral Sakauchi,Dirce Silva,Luciana Leite da |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Matos,Denise Cristina Souza Marcovistz,Rugimar Cabello,Pedro Hernan Georgini,Ricardo Amaral Sakauchi,Dirce Silva,Luciana Leite da |
dc.subject.por.fl_str_mv |
diphtheria-tetanus vaccine diphtheria-tetanus-pertussis vaccine toxin binding inhibition test tetanus quality control seroneutralization |
topic |
diphtheria-tetanus vaccine diphtheria-tetanus-pertussis vaccine toxin binding inhibition test tetanus quality control seroneutralization |
dc.description.none.fl_txt_mv |
Samples from 20 lots of diphtheria-tetanus (adult use dT) vaccine and from 20 lots of diphtheria-tetanus-pertussis (DTP) vaccine were used to standardize and validate the in vitro toxin binding inhibition (ToBI) test for the immunogenicity test of the tetanus component. The levels of tetanus antitoxin obtained by ToBI test were compared to those obtained using the toxin neutralization (TN) test in mice routinely employed to perform the quality control of the tetanus component in adsorbed vaccines. The results ranged from 1.8 to 3.5 IU/ml for dT and 2 to 4 IU/ml for DTP by ToBI test and 1.4 to 3 IU/ml for dT and 1.8 to 3.5 IU/ml for DTP by TN in mice. These results were significantly correlated. From this study, it is concluded that the ToBI test is an alternative to the in vivo neutralization procedure in the immunogenicity test of the tetanus component in adsorbed vaccines. A substantial refinement and a reduction in use of animals can be achieved. |
description |
Samples from 20 lots of diphtheria-tetanus (adult use dT) vaccine and from 20 lots of diphtheria-tetanus-pertussis (DTP) vaccine were used to standardize and validate the in vitro toxin binding inhibition (ToBI) test for the immunogenicity test of the tetanus component. The levels of tetanus antitoxin obtained by ToBI test were compared to those obtained using the toxin neutralization (TN) test in mice routinely employed to perform the quality control of the tetanus component in adsorbed vaccines. The results ranged from 1.8 to 3.5 IU/ml for dT and 2 to 4 IU/ml for DTP by ToBI test and 1.4 to 3 IU/ml for dT and 1.8 to 3.5 IU/ml for DTP by TN in mice. These results were significantly correlated. From this study, it is concluded that the ToBI test is an alternative to the in vivo neutralization procedure in the immunogenicity test of the tetanus component in adsorbed vaccines. A substantial refinement and a reduction in use of animals can be achieved. |
publishDate |
2002 |
dc.date.none.fl_str_mv |
2002-09-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02762002000600030 |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02762002000600030 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0074-02762002000600030 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Instituto Oswaldo Cruz, Ministério da Saúde |
publisher.none.fl_str_mv |
Instituto Oswaldo Cruz, Ministério da Saúde |
dc.source.none.fl_str_mv |
Memórias do Instituto Oswaldo Cruz v.97 n.6 2002 reponame:Memórias do Instituto Oswaldo Cruz instname:Fundação Oswaldo Cruz instacron:FIOCRUZ |
reponame_str |
Memórias do Instituto Oswaldo Cruz |
collection |
Memórias do Instituto Oswaldo Cruz |
instname_str |
Fundação Oswaldo Cruz |
instacron_str |
FIOCRUZ |
institution |
FIOCRUZ |
repository.name.fl_str_mv |
Memórias do Instituto Oswaldo Cruz - Fundação Oswaldo Cruz |
repository.mail.fl_str_mv |
|
_version_ |
1669937686750691328 |