P3 Cognitive Potential in Cochlear Implant Users
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | International Archives of Otorhinolaryngology |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642018000400408 |
Resumo: | Abstract Introduction The P3 cognitive evoked potential is recorded when a subject correctly identifies, evaluates and processes two different auditory stimuli. Objective to evaluate the latency and amplitude of the P3 evoked potential in 26 cochlear implant users with post-lingual deafness with good or poor speech recognition scores as compared with normal hearing subjects matched for age and educational level. Methods In this prospective cohort study, auditory cortical responses were recorded from 26 post-lingual deaf adult cochlear implant users (19 with good and 7 with poor speech recognition scores) and 26 control subjects. Results There was a significant difference in the P3 latency between cochlear implant users with poor speech recognition scores (G-) and their control group (CG) (p= 0.04), and between G- and cochlear implant users with good speech discrimination (G+) (p= 0.01). We found no significant difference in the P3 latency between the CG and G+. In this study, all G- patients had deafness due to meningitis, which suggests that higher auditory function was impaired too. Conclusion Post-lingual deaf adult cochlear implant users in the G- group had prolonged P3 latencies as compared with the CG and the cochlear implant users in the G+ group. The amplitudes were similar between patients and controls. All G- subjects were deaf due to meningitis. These findings suggest that meningitis may have deleterious effects not only on the peripheral auditory system but on the central auditory processing as well. |
id |
FORL-1_5f5bf3b56fd9289bd5b642e6cb497407 |
---|---|
oai_identifier_str |
oai:scielo:S1809-48642018000400408 |
network_acronym_str |
FORL-1 |
network_name_str |
International Archives of Otorhinolaryngology |
repository_id_str |
|
spelling |
P3 Cognitive Potential in Cochlear Implant UsersP3 event-related potentialscochlear implantspeech discriminationAbstract Introduction The P3 cognitive evoked potential is recorded when a subject correctly identifies, evaluates and processes two different auditory stimuli. Objective to evaluate the latency and amplitude of the P3 evoked potential in 26 cochlear implant users with post-lingual deafness with good or poor speech recognition scores as compared with normal hearing subjects matched for age and educational level. Methods In this prospective cohort study, auditory cortical responses were recorded from 26 post-lingual deaf adult cochlear implant users (19 with good and 7 with poor speech recognition scores) and 26 control subjects. Results There was a significant difference in the P3 latency between cochlear implant users with poor speech recognition scores (G-) and their control group (CG) (p= 0.04), and between G- and cochlear implant users with good speech discrimination (G+) (p= 0.01). We found no significant difference in the P3 latency between the CG and G+. In this study, all G- patients had deafness due to meningitis, which suggests that higher auditory function was impaired too. Conclusion Post-lingual deaf adult cochlear implant users in the G- group had prolonged P3 latencies as compared with the CG and the cochlear implant users in the G+ group. The amplitudes were similar between patients and controls. All G- subjects were deaf due to meningitis. These findings suggest that meningitis may have deleterious effects not only on the peripheral auditory system but on the central auditory processing as well.Fundação Otorrinolaringologia2018-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642018000400408International Archives of Otorhinolaryngology v.22 n.4 2018reponame:International Archives of Otorhinolaryngologyinstname:Fundação Otorrinolaringologia (FORL)instacron:FORL10.1055/s-0037-1613687info:eu-repo/semantics/openAccessGrasel,SigneGreters,MarioGoffi-Gomez,Maria Valeria SchimidtBittar,RoseliWeber,RaimarOiticica,JeanneBento,Ricardo Ferreiraeng2018-12-19T00:00:00Zoai:scielo:S1809-48642018000400408Revistahttps://www.scielo.br/j/iao/https://old.scielo.br/oai/scielo-oai.php||iaorl@iaorl.org||archives@internationalarchivesent.org||arquivos@forl.org.br1809-48641809-4864opendoar:2018-12-19T00:00International Archives of Otorhinolaryngology - Fundação Otorrinolaringologia (FORL)false |
dc.title.none.fl_str_mv |
P3 Cognitive Potential in Cochlear Implant Users |
title |
P3 Cognitive Potential in Cochlear Implant Users |
spellingShingle |
P3 Cognitive Potential in Cochlear Implant Users Grasel,Signe P3 event-related potentials cochlear implant speech discrimination |
title_short |
P3 Cognitive Potential in Cochlear Implant Users |
title_full |
P3 Cognitive Potential in Cochlear Implant Users |
title_fullStr |
P3 Cognitive Potential in Cochlear Implant Users |
title_full_unstemmed |
P3 Cognitive Potential in Cochlear Implant Users |
title_sort |
P3 Cognitive Potential in Cochlear Implant Users |
author |
Grasel,Signe |
author_facet |
Grasel,Signe Greters,Mario Goffi-Gomez,Maria Valeria Schimidt Bittar,Roseli Weber,Raimar Oiticica,Jeanne Bento,Ricardo Ferreira |
author_role |
author |
author2 |
Greters,Mario Goffi-Gomez,Maria Valeria Schimidt Bittar,Roseli Weber,Raimar Oiticica,Jeanne Bento,Ricardo Ferreira |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Grasel,Signe Greters,Mario Goffi-Gomez,Maria Valeria Schimidt Bittar,Roseli Weber,Raimar Oiticica,Jeanne Bento,Ricardo Ferreira |
dc.subject.por.fl_str_mv |
P3 event-related potentials cochlear implant speech discrimination |
topic |
P3 event-related potentials cochlear implant speech discrimination |
description |
Abstract Introduction The P3 cognitive evoked potential is recorded when a subject correctly identifies, evaluates and processes two different auditory stimuli. Objective to evaluate the latency and amplitude of the P3 evoked potential in 26 cochlear implant users with post-lingual deafness with good or poor speech recognition scores as compared with normal hearing subjects matched for age and educational level. Methods In this prospective cohort study, auditory cortical responses were recorded from 26 post-lingual deaf adult cochlear implant users (19 with good and 7 with poor speech recognition scores) and 26 control subjects. Results There was a significant difference in the P3 latency between cochlear implant users with poor speech recognition scores (G-) and their control group (CG) (p= 0.04), and between G- and cochlear implant users with good speech discrimination (G+) (p= 0.01). We found no significant difference in the P3 latency between the CG and G+. In this study, all G- patients had deafness due to meningitis, which suggests that higher auditory function was impaired too. Conclusion Post-lingual deaf adult cochlear implant users in the G- group had prolonged P3 latencies as compared with the CG and the cochlear implant users in the G+ group. The amplitudes were similar between patients and controls. All G- subjects were deaf due to meningitis. These findings suggest that meningitis may have deleterious effects not only on the peripheral auditory system but on the central auditory processing as well. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642018000400408 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642018000400408 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1055/s-0037-1613687 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Fundação Otorrinolaringologia |
publisher.none.fl_str_mv |
Fundação Otorrinolaringologia |
dc.source.none.fl_str_mv |
International Archives of Otorhinolaryngology v.22 n.4 2018 reponame:International Archives of Otorhinolaryngology instname:Fundação Otorrinolaringologia (FORL) instacron:FORL |
instname_str |
Fundação Otorrinolaringologia (FORL) |
instacron_str |
FORL |
institution |
FORL |
reponame_str |
International Archives of Otorhinolaryngology |
collection |
International Archives of Otorhinolaryngology |
repository.name.fl_str_mv |
International Archives of Otorhinolaryngology - Fundação Otorrinolaringologia (FORL) |
repository.mail.fl_str_mv |
||iaorl@iaorl.org||archives@internationalarchivesent.org||arquivos@forl.org.br |
_version_ |
1754203976153169920 |