Are Hounsfield Unit Measurements of Bony Absorption Changes in Cholesteatoma Helpful?
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | International Archives of Otorhinolaryngology |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642022000300414 |
Resumo: | Abstract Introduction High-resolution computed tomography (HRCT) scans of the temporal bone are used to assess the bony erosion of the middle-ear structures whenever cholesteatoma is suspected. Objective To study the differences in HRCT Hounsfield unit (HU) index measurements of middle-ear bony structures between an ears with and without cholesteatoma. Methods A retrospective study of 59 patients who underwent surgery due to unilateral cholesteatoma. The HRCT HU index of the scutum, of three middle-ear ossicles, of the lateral semicircular canal (LSCC), and of the fallopian canal was measured in both ears. A comparison was made between the cholesteatoma and the non-cholesteatomatous ear (control). All measurements were conducted by an otolaryngologist. To assess the interobserver bias, 10% of the samples were randomly and independently assessed by another otolaryngologist and a neuroradiologist who were blinded. Results The average HU index was lower in the ear with cholesteatoma when compared with the non-cholesteatomatous ear. While the differences were statistically significant regarding the measurements of the scutum (516.02 ± 311.693 versus 855.64 ± 389.999; p = 0.001), the malleus (1049.44 ± 481.765 versus 1413.47 ± 313.376; p = 0.01), and the incus (498.03 ± 264.184 versus 714.25 ± 405.631; p = 0.001), the differences in the measurements of the LSCC (1042.34 ± 301.066 versus 1154.53 ± 359.609; p = 0.69) and of the fallopian canal (467.19 ± 221.556 versus 543.51 ± 263.573; p = 0.108) were not significantly different between both groups. The stapes was immeasurable in both groups due to its small size. Conclusion Hounsfield unit index measurements are a useful tool that may aid in the diagnosis of early-stage cholesteatoma. |
id |
FORL-1_7fbb73129ebfab526233265408779338 |
---|---|
oai_identifier_str |
oai:scielo:S1809-48642022000300414 |
network_acronym_str |
FORL-1 |
network_name_str |
International Archives of Otorhinolaryngology |
repository_id_str |
|
spelling |
Are Hounsfield Unit Measurements of Bony Absorption Changes in Cholesteatoma Helpful?computed tomographyHounsfield unitcholesteatomaossiclesAbstract Introduction High-resolution computed tomography (HRCT) scans of the temporal bone are used to assess the bony erosion of the middle-ear structures whenever cholesteatoma is suspected. Objective To study the differences in HRCT Hounsfield unit (HU) index measurements of middle-ear bony structures between an ears with and without cholesteatoma. Methods A retrospective study of 59 patients who underwent surgery due to unilateral cholesteatoma. The HRCT HU index of the scutum, of three middle-ear ossicles, of the lateral semicircular canal (LSCC), and of the fallopian canal was measured in both ears. A comparison was made between the cholesteatoma and the non-cholesteatomatous ear (control). All measurements were conducted by an otolaryngologist. To assess the interobserver bias, 10% of the samples were randomly and independently assessed by another otolaryngologist and a neuroradiologist who were blinded. Results The average HU index was lower in the ear with cholesteatoma when compared with the non-cholesteatomatous ear. While the differences were statistically significant regarding the measurements of the scutum (516.02 ± 311.693 versus 855.64 ± 389.999; p = 0.001), the malleus (1049.44 ± 481.765 versus 1413.47 ± 313.376; p = 0.01), and the incus (498.03 ± 264.184 versus 714.25 ± 405.631; p = 0.001), the differences in the measurements of the LSCC (1042.34 ± 301.066 versus 1154.53 ± 359.609; p = 0.69) and of the fallopian canal (467.19 ± 221.556 versus 543.51 ± 263.573; p = 0.108) were not significantly different between both groups. The stapes was immeasurable in both groups due to its small size. Conclusion Hounsfield unit index measurements are a useful tool that may aid in the diagnosis of early-stage cholesteatoma.Fundação Otorrinolaringologia2022-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642022000300414International Archives of Otorhinolaryngology v.26 n.3 2022reponame:International Archives of Otorhinolaryngologyinstname:Fundação Otorrinolaringologia (FORL)instacron:FORL10.1055/s-0041-1736580info:eu-repo/semantics/openAccessShemesh,ShayLuckman,JudithMarom,TalKraus,OdedTamir,Sharon Ovnateng2022-11-01T00:00:00Zoai:scielo:S1809-48642022000300414Revistahttps://www.scielo.br/j/iao/https://old.scielo.br/oai/scielo-oai.php||iaorl@iaorl.org||archives@internationalarchivesent.org||arquivos@forl.org.br1809-48641809-4864opendoar:2022-11-01T00:00International Archives of Otorhinolaryngology - Fundação Otorrinolaringologia (FORL)false |
dc.title.none.fl_str_mv |
Are Hounsfield Unit Measurements of Bony Absorption Changes in Cholesteatoma Helpful? |
title |
Are Hounsfield Unit Measurements of Bony Absorption Changes in Cholesteatoma Helpful? |
spellingShingle |
Are Hounsfield Unit Measurements of Bony Absorption Changes in Cholesteatoma Helpful? Shemesh,Shay computed tomography Hounsfield unit cholesteatoma ossicles |
title_short |
Are Hounsfield Unit Measurements of Bony Absorption Changes in Cholesteatoma Helpful? |
title_full |
Are Hounsfield Unit Measurements of Bony Absorption Changes in Cholesteatoma Helpful? |
title_fullStr |
Are Hounsfield Unit Measurements of Bony Absorption Changes in Cholesteatoma Helpful? |
title_full_unstemmed |
Are Hounsfield Unit Measurements of Bony Absorption Changes in Cholesteatoma Helpful? |
title_sort |
Are Hounsfield Unit Measurements of Bony Absorption Changes in Cholesteatoma Helpful? |
author |
Shemesh,Shay |
author_facet |
Shemesh,Shay Luckman,Judith Marom,Tal Kraus,Oded Tamir,Sharon Ovnat |
author_role |
author |
author2 |
Luckman,Judith Marom,Tal Kraus,Oded Tamir,Sharon Ovnat |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Shemesh,Shay Luckman,Judith Marom,Tal Kraus,Oded Tamir,Sharon Ovnat |
dc.subject.por.fl_str_mv |
computed tomography Hounsfield unit cholesteatoma ossicles |
topic |
computed tomography Hounsfield unit cholesteatoma ossicles |
description |
Abstract Introduction High-resolution computed tomography (HRCT) scans of the temporal bone are used to assess the bony erosion of the middle-ear structures whenever cholesteatoma is suspected. Objective To study the differences in HRCT Hounsfield unit (HU) index measurements of middle-ear bony structures between an ears with and without cholesteatoma. Methods A retrospective study of 59 patients who underwent surgery due to unilateral cholesteatoma. The HRCT HU index of the scutum, of three middle-ear ossicles, of the lateral semicircular canal (LSCC), and of the fallopian canal was measured in both ears. A comparison was made between the cholesteatoma and the non-cholesteatomatous ear (control). All measurements were conducted by an otolaryngologist. To assess the interobserver bias, 10% of the samples were randomly and independently assessed by another otolaryngologist and a neuroradiologist who were blinded. Results The average HU index was lower in the ear with cholesteatoma when compared with the non-cholesteatomatous ear. While the differences were statistically significant regarding the measurements of the scutum (516.02 ± 311.693 versus 855.64 ± 389.999; p = 0.001), the malleus (1049.44 ± 481.765 versus 1413.47 ± 313.376; p = 0.01), and the incus (498.03 ± 264.184 versus 714.25 ± 405.631; p = 0.001), the differences in the measurements of the LSCC (1042.34 ± 301.066 versus 1154.53 ± 359.609; p = 0.69) and of the fallopian canal (467.19 ± 221.556 versus 543.51 ± 263.573; p = 0.108) were not significantly different between both groups. The stapes was immeasurable in both groups due to its small size. Conclusion Hounsfield unit index measurements are a useful tool that may aid in the diagnosis of early-stage cholesteatoma. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-09-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642022000300414 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642022000300414 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1055/s-0041-1736580 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Fundação Otorrinolaringologia |
publisher.none.fl_str_mv |
Fundação Otorrinolaringologia |
dc.source.none.fl_str_mv |
International Archives of Otorhinolaryngology v.26 n.3 2022 reponame:International Archives of Otorhinolaryngology instname:Fundação Otorrinolaringologia (FORL) instacron:FORL |
instname_str |
Fundação Otorrinolaringologia (FORL) |
instacron_str |
FORL |
institution |
FORL |
reponame_str |
International Archives of Otorhinolaryngology |
collection |
International Archives of Otorhinolaryngology |
repository.name.fl_str_mv |
International Archives of Otorhinolaryngology - Fundação Otorrinolaringologia (FORL) |
repository.mail.fl_str_mv |
||iaorl@iaorl.org||archives@internationalarchivesent.org||arquivos@forl.org.br |
_version_ |
1754203977490104320 |