Postoperative Benefit of Bone Anchored Hearing Systems: Behavioral Performance and Self-Reported Outcomes
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | International Archives of Otorhinolaryngology |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642022000300314 |
Resumo: | Abstract Introduction Bone anchored hearing solutions are a well-known option for patients with a conductive, mixed conductive-sensorineural hearing loss and those with single-sided deafness. Objective The aim of the present study was to evaluate the Ponto bone-anchored hearing system in terms of behavioral performance and self-reported outcomes, by comparing unaided and aided performance (softband and abutment), as well as aided performance with the sound processor on softband (preoperatively) versus abutment (postoperatively). Methods Fourteen adult bone-anchored candidates, with either a bilateral (n = 12) or unilateral (n = 2) conductive or mixed hearing loss, participated in the present study. Sound-field hearing thresholds were evaluated unaided and aided (softband and abutment). A speech-in-noise test was also performed unaided and aided for two spatial configurations (S0N90; implanted side; S0N90; nonimplanted side). The Glasgow Health Status Inventory and the Speech, Spatial and Quality of sound questionnaires were administered pre- and postsurgery to compare quality of life and perceived unaided and aided performance. Skin reaction (Holgers scores) was evaluated at 15 days, 6 weeks, and 10 weeks after surgery. Results Significant improvements postoperatively relative to unaided were obtained for sound-field thresholds at all tested frequencies. Additionally, sound-field thresholds were significantly improved with the sound processor on abutment relative to the softband at frequencies > 1 kHz. Improved performance postoperatively relative to unaided was also obtained in the speech-in-noise test and in self-reported outcomes. Conclusions Improvements in behavioral performance and self-reported outcomes were obtained with the sound processor mounted on abutment. |
id |
FORL-1_f6a3f476a9a4578b950388710a853c2e |
---|---|
oai_identifier_str |
oai:scielo:S1809-48642022000300314 |
network_acronym_str |
FORL-1 |
network_name_str |
International Archives of Otorhinolaryngology |
repository_id_str |
|
spelling |
Postoperative Benefit of Bone Anchored Hearing Systems: Behavioral Performance and Self-Reported Outcomesmixed hearing lossconductive hearing losshearing aidhealth-related quality of lifeAbstract Introduction Bone anchored hearing solutions are a well-known option for patients with a conductive, mixed conductive-sensorineural hearing loss and those with single-sided deafness. Objective The aim of the present study was to evaluate the Ponto bone-anchored hearing system in terms of behavioral performance and self-reported outcomes, by comparing unaided and aided performance (softband and abutment), as well as aided performance with the sound processor on softband (preoperatively) versus abutment (postoperatively). Methods Fourteen adult bone-anchored candidates, with either a bilateral (n = 12) or unilateral (n = 2) conductive or mixed hearing loss, participated in the present study. Sound-field hearing thresholds were evaluated unaided and aided (softband and abutment). A speech-in-noise test was also performed unaided and aided for two spatial configurations (S0N90; implanted side; S0N90; nonimplanted side). The Glasgow Health Status Inventory and the Speech, Spatial and Quality of sound questionnaires were administered pre- and postsurgery to compare quality of life and perceived unaided and aided performance. Skin reaction (Holgers scores) was evaluated at 15 days, 6 weeks, and 10 weeks after surgery. Results Significant improvements postoperatively relative to unaided were obtained for sound-field thresholds at all tested frequencies. Additionally, sound-field thresholds were significantly improved with the sound processor on abutment relative to the softband at frequencies > 1 kHz. Improved performance postoperatively relative to unaided was also obtained in the speech-in-noise test and in self-reported outcomes. Conclusions Improvements in behavioral performance and self-reported outcomes were obtained with the sound processor mounted on abutment.Fundação Otorrinolaringologia2022-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642022000300314International Archives of Otorhinolaryngology v.26 n.3 2022reponame:International Archives of Otorhinolaryngologyinstname:Fundação Otorrinolaringologia (FORL)instacron:FORL10.1055/s-0040-1718959info:eu-repo/semantics/openAccessCuda,DomenicoMurri,AlessandraMochi,PaoloMainardi,Annaeng2022-11-01T00:00:00Zoai:scielo:S1809-48642022000300314Revistahttps://www.scielo.br/j/iao/https://old.scielo.br/oai/scielo-oai.php||iaorl@iaorl.org||archives@internationalarchivesent.org||arquivos@forl.org.br1809-48641809-4864opendoar:2022-11-01T00:00International Archives of Otorhinolaryngology - Fundação Otorrinolaringologia (FORL)false |
dc.title.none.fl_str_mv |
Postoperative Benefit of Bone Anchored Hearing Systems: Behavioral Performance and Self-Reported Outcomes |
title |
Postoperative Benefit of Bone Anchored Hearing Systems: Behavioral Performance and Self-Reported Outcomes |
spellingShingle |
Postoperative Benefit of Bone Anchored Hearing Systems: Behavioral Performance and Self-Reported Outcomes Cuda,Domenico mixed hearing loss conductive hearing loss hearing aid health-related quality of life |
title_short |
Postoperative Benefit of Bone Anchored Hearing Systems: Behavioral Performance and Self-Reported Outcomes |
title_full |
Postoperative Benefit of Bone Anchored Hearing Systems: Behavioral Performance and Self-Reported Outcomes |
title_fullStr |
Postoperative Benefit of Bone Anchored Hearing Systems: Behavioral Performance and Self-Reported Outcomes |
title_full_unstemmed |
Postoperative Benefit of Bone Anchored Hearing Systems: Behavioral Performance and Self-Reported Outcomes |
title_sort |
Postoperative Benefit of Bone Anchored Hearing Systems: Behavioral Performance and Self-Reported Outcomes |
author |
Cuda,Domenico |
author_facet |
Cuda,Domenico Murri,Alessandra Mochi,Paolo Mainardi,Anna |
author_role |
author |
author2 |
Murri,Alessandra Mochi,Paolo Mainardi,Anna |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Cuda,Domenico Murri,Alessandra Mochi,Paolo Mainardi,Anna |
dc.subject.por.fl_str_mv |
mixed hearing loss conductive hearing loss hearing aid health-related quality of life |
topic |
mixed hearing loss conductive hearing loss hearing aid health-related quality of life |
description |
Abstract Introduction Bone anchored hearing solutions are a well-known option for patients with a conductive, mixed conductive-sensorineural hearing loss and those with single-sided deafness. Objective The aim of the present study was to evaluate the Ponto bone-anchored hearing system in terms of behavioral performance and self-reported outcomes, by comparing unaided and aided performance (softband and abutment), as well as aided performance with the sound processor on softband (preoperatively) versus abutment (postoperatively). Methods Fourteen adult bone-anchored candidates, with either a bilateral (n = 12) or unilateral (n = 2) conductive or mixed hearing loss, participated in the present study. Sound-field hearing thresholds were evaluated unaided and aided (softband and abutment). A speech-in-noise test was also performed unaided and aided for two spatial configurations (S0N90; implanted side; S0N90; nonimplanted side). The Glasgow Health Status Inventory and the Speech, Spatial and Quality of sound questionnaires were administered pre- and postsurgery to compare quality of life and perceived unaided and aided performance. Skin reaction (Holgers scores) was evaluated at 15 days, 6 weeks, and 10 weeks after surgery. Results Significant improvements postoperatively relative to unaided were obtained for sound-field thresholds at all tested frequencies. Additionally, sound-field thresholds were significantly improved with the sound processor on abutment relative to the softband at frequencies > 1 kHz. Improved performance postoperatively relative to unaided was also obtained in the speech-in-noise test and in self-reported outcomes. Conclusions Improvements in behavioral performance and self-reported outcomes were obtained with the sound processor mounted on abutment. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-09-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642022000300314 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1809-48642022000300314 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1055/s-0040-1718959 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Fundação Otorrinolaringologia |
publisher.none.fl_str_mv |
Fundação Otorrinolaringologia |
dc.source.none.fl_str_mv |
International Archives of Otorhinolaryngology v.26 n.3 2022 reponame:International Archives of Otorhinolaryngology instname:Fundação Otorrinolaringologia (FORL) instacron:FORL |
instname_str |
Fundação Otorrinolaringologia (FORL) |
instacron_str |
FORL |
institution |
FORL |
reponame_str |
International Archives of Otorhinolaryngology |
collection |
International Archives of Otorhinolaryngology |
repository.name.fl_str_mv |
International Archives of Otorhinolaryngology - Fundação Otorrinolaringologia (FORL) |
repository.mail.fl_str_mv |
||iaorl@iaorl.org||archives@internationalarchivesent.org||arquivos@forl.org.br |
_version_ |
1754203977462841344 |