Characterization of Bis-Acryl Composite Resins for Provisional Restorations

Detalhes bibliográficos
Autor(a) principal: Schwantz,Júlia K.
Data de Publicação: 2017
Outros Autores: Oliveira-Ogliari,Aline, Meereis,Carine T., Leal,Fernanda B., Ogliari,Fabrício A., Moraes,Rafael R.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402017000300354
Resumo: Abstract This study investigated the in vitro performance of the commercial bis-acryl composite resins Systemp C&B II (SYS, Ivoclar Vivadent), Protemp 4 (PT4, 3M ESPE), Structur 2C (ST2, Voco) and ProviPlast (PVP, Biodinamica). Characterization involved optical (color stability, translucency parameter, fluorescence), surface (roughness, morphology and elemental composition), physical-chemical (viscosity, polymerization kinetics) and mechanical analyses (Poisson ratio, biaxial flexural strength, flexural modulus). Most tests were carried out after 24 h, but optical and mechanical analyses were carried out after storage in water at 37 °C for 1, 15, and 30 days. Data were statistically analyzed (a=0.05). Most results were material dependent. SYS and PT4 showed stability in color and translucency over time. All materials had similar or higher fluorescence than human enamel. SC2 and PVP showed rougher surfaces than the other bis-acryl composites. Smaller filler particles were observed on the surface of PT4 and PVP compared with the coarser particles from ST2 and SYS. Viscosity readings indicated a thixotropic behavior for all tested materials. SYS had the lowest and PT4 the highest degree of C=C conversion after 10 min. In the polymerization kinetics, PT4 had the highest maximum polymerization rate and reached earlier the transition between polymerization autoacceleration and autodeceleration. PT4 and SYS had significantly higher flexural strength and modulus than ST2 and PVP for most storage times. Results for Poisson ratio varied between materials. Longer storage periods were generally associated with higher frequency of catastrophic failures in the flexural tests. In conclusion, the performance of bis-acryl composite resins varied largely among materials.
id FUNORP-1_039c7b08fcac69c14d9cab4622945f80
oai_identifier_str oai:scielo:S0103-64402017000300354
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Characterization of Bis-Acryl Composite Resins for Provisional Restorationsmechanical strengthoptical analysesphysical-chemical propertiessurface properties.Abstract This study investigated the in vitro performance of the commercial bis-acryl composite resins Systemp C&B II (SYS, Ivoclar Vivadent), Protemp 4 (PT4, 3M ESPE), Structur 2C (ST2, Voco) and ProviPlast (PVP, Biodinamica). Characterization involved optical (color stability, translucency parameter, fluorescence), surface (roughness, morphology and elemental composition), physical-chemical (viscosity, polymerization kinetics) and mechanical analyses (Poisson ratio, biaxial flexural strength, flexural modulus). Most tests were carried out after 24 h, but optical and mechanical analyses were carried out after storage in water at 37 °C for 1, 15, and 30 days. Data were statistically analyzed (a=0.05). Most results were material dependent. SYS and PT4 showed stability in color and translucency over time. All materials had similar or higher fluorescence than human enamel. SC2 and PVP showed rougher surfaces than the other bis-acryl composites. Smaller filler particles were observed on the surface of PT4 and PVP compared with the coarser particles from ST2 and SYS. Viscosity readings indicated a thixotropic behavior for all tested materials. SYS had the lowest and PT4 the highest degree of C=C conversion after 10 min. In the polymerization kinetics, PT4 had the highest maximum polymerization rate and reached earlier the transition between polymerization autoacceleration and autodeceleration. PT4 and SYS had significantly higher flexural strength and modulus than ST2 and PVP for most storage times. Results for Poisson ratio varied between materials. Longer storage periods were generally associated with higher frequency of catastrophic failures in the flexural tests. In conclusion, the performance of bis-acryl composite resins varied largely among materials.Fundação Odontológica de Ribeirão Preto2017-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402017000300354Brazilian Dental Journal v.28 n.3 2017reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/0103-6440201601418info:eu-repo/semantics/openAccessSchwantz,Júlia K.Oliveira-Ogliari,AlineMeereis,Carine T.Leal,Fernanda B.Ogliari,Fabrício A.Moraes,Rafael R.eng2017-08-03T00:00:00Zoai:scielo:S0103-64402017000300354Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2017-08-03T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Characterization of Bis-Acryl Composite Resins for Provisional Restorations
title Characterization of Bis-Acryl Composite Resins for Provisional Restorations
spellingShingle Characterization of Bis-Acryl Composite Resins for Provisional Restorations
Schwantz,Júlia K.
mechanical strength
optical analyses
physical-chemical properties
surface properties.
title_short Characterization of Bis-Acryl Composite Resins for Provisional Restorations
title_full Characterization of Bis-Acryl Composite Resins for Provisional Restorations
title_fullStr Characterization of Bis-Acryl Composite Resins for Provisional Restorations
title_full_unstemmed Characterization of Bis-Acryl Composite Resins for Provisional Restorations
title_sort Characterization of Bis-Acryl Composite Resins for Provisional Restorations
author Schwantz,Júlia K.
author_facet Schwantz,Júlia K.
Oliveira-Ogliari,Aline
Meereis,Carine T.
Leal,Fernanda B.
Ogliari,Fabrício A.
Moraes,Rafael R.
author_role author
author2 Oliveira-Ogliari,Aline
Meereis,Carine T.
Leal,Fernanda B.
Ogliari,Fabrício A.
Moraes,Rafael R.
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Schwantz,Júlia K.
Oliveira-Ogliari,Aline
Meereis,Carine T.
Leal,Fernanda B.
Ogliari,Fabrício A.
Moraes,Rafael R.
dc.subject.por.fl_str_mv mechanical strength
optical analyses
physical-chemical properties
surface properties.
topic mechanical strength
optical analyses
physical-chemical properties
surface properties.
description Abstract This study investigated the in vitro performance of the commercial bis-acryl composite resins Systemp C&B II (SYS, Ivoclar Vivadent), Protemp 4 (PT4, 3M ESPE), Structur 2C (ST2, Voco) and ProviPlast (PVP, Biodinamica). Characterization involved optical (color stability, translucency parameter, fluorescence), surface (roughness, morphology and elemental composition), physical-chemical (viscosity, polymerization kinetics) and mechanical analyses (Poisson ratio, biaxial flexural strength, flexural modulus). Most tests were carried out after 24 h, but optical and mechanical analyses were carried out after storage in water at 37 °C for 1, 15, and 30 days. Data were statistically analyzed (a=0.05). Most results were material dependent. SYS and PT4 showed stability in color and translucency over time. All materials had similar or higher fluorescence than human enamel. SC2 and PVP showed rougher surfaces than the other bis-acryl composites. Smaller filler particles were observed on the surface of PT4 and PVP compared with the coarser particles from ST2 and SYS. Viscosity readings indicated a thixotropic behavior for all tested materials. SYS had the lowest and PT4 the highest degree of C=C conversion after 10 min. In the polymerization kinetics, PT4 had the highest maximum polymerization rate and reached earlier the transition between polymerization autoacceleration and autodeceleration. PT4 and SYS had significantly higher flexural strength and modulus than ST2 and PVP for most storage times. Results for Poisson ratio varied between materials. Longer storage periods were generally associated with higher frequency of catastrophic failures in the flexural tests. In conclusion, the performance of bis-acryl composite resins varied largely among materials.
publishDate 2017
dc.date.none.fl_str_mv 2017-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402017000300354
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402017000300354
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0103-6440201601418
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.28 n.3 2017
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204094792204288