Flexural and diametral tensile strength of composite resins

Detalhes bibliográficos
Autor(a) principal: Della Bona,Álvaro
Data de Publicação: 2008
Outros Autores: Benetti,Paula, Borba,Márcia, Cecchetti,Dileta
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242008000100015
Resumo: This study evaluated the flexural strength (sf) and the diametral tensile strength (st) of light-cured composite resins, testing the hypothesis that there is a positive relation between these properties. Twenty specimens were fabricated for each material (Filtek Z250- 3M-Espe; AM- Amelogen, Ultradent; VE- Vit-l-escence, Ultradent; EX- Esthet-X, Dentsply/Caulk), following ISO 4049 and ANSI/ADA 27 specifications and the manufacturers’ instructions. For the st test, cylindrical shaped (4 mm x 6 mm) specimens (n = 10) were placed with their long axes perpendicular to the applied compressive load at a crosshead speed of 1.0 mm/min. The sf was measured using the 3-point bending test, in which bar shaped specimens (n = 10) were tested at a crosshead speed of 0.5 mm/min. Both tests were performed in a universal testing machine (EMIC 2000) recording the fracture load (N). Strength values (MPa) were calculated and statistically analyzed by ANOVA and Tukey (a = 0.05). The mean and standard deviation values (MPa) were Z250-45.06 ± 5.7; AM-35.61 ± 5.4; VE-34.45 ± 7.8; and EX-42.87 ± 6.6 for st; and Z250-126.52 ± 3.3; AM-87.75 ± 3.8; VE-104.66 ± 4.4; and EX-119.48 ± 2.1 for sf. EX and Z250 showed higher st and sf values than the other materials evaluated (p < 0.05), which followed a decreasing trend of mean values. The results confirmed the study hypothesis, showing a positive relation between the material properties examined.
id SBPQO-1_406bacd03dccc3816088c496465aa68f
oai_identifier_str oai:scielo:S1806-83242008000100015
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Flexural and diametral tensile strength of composite resinsComposite resinsTensile strengthPhysical propertiesThis study evaluated the flexural strength (sf) and the diametral tensile strength (st) of light-cured composite resins, testing the hypothesis that there is a positive relation between these properties. Twenty specimens were fabricated for each material (Filtek Z250- 3M-Espe; AM- Amelogen, Ultradent; VE- Vit-l-escence, Ultradent; EX- Esthet-X, Dentsply/Caulk), following ISO 4049 and ANSI/ADA 27 specifications and the manufacturers’ instructions. For the st test, cylindrical shaped (4 mm x 6 mm) specimens (n = 10) were placed with their long axes perpendicular to the applied compressive load at a crosshead speed of 1.0 mm/min. The sf was measured using the 3-point bending test, in which bar shaped specimens (n = 10) were tested at a crosshead speed of 0.5 mm/min. Both tests were performed in a universal testing machine (EMIC 2000) recording the fracture load (N). Strength values (MPa) were calculated and statistically analyzed by ANOVA and Tukey (a = 0.05). The mean and standard deviation values (MPa) were Z250-45.06 ± 5.7; AM-35.61 ± 5.4; VE-34.45 ± 7.8; and EX-42.87 ± 6.6 for st; and Z250-126.52 ± 3.3; AM-87.75 ± 3.8; VE-104.66 ± 4.4; and EX-119.48 ± 2.1 for sf. EX and Z250 showed higher st and sf values than the other materials evaluated (p < 0.05), which followed a decreasing trend of mean values. The results confirmed the study hypothesis, showing a positive relation between the material properties examined.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2008-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242008000100015Brazilian Oral Research v.22 n.1 2008reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242008000100015info:eu-repo/semantics/openAccessDella Bona,ÁlvaroBenetti,PaulaBorba,MárciaCecchetti,Diletaeng2008-04-10T00:00:00Zoai:scielo:S1806-83242008000100015Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2008-04-10T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Flexural and diametral tensile strength of composite resins
title Flexural and diametral tensile strength of composite resins
spellingShingle Flexural and diametral tensile strength of composite resins
Della Bona,Álvaro
Composite resins
Tensile strength
Physical properties
title_short Flexural and diametral tensile strength of composite resins
title_full Flexural and diametral tensile strength of composite resins
title_fullStr Flexural and diametral tensile strength of composite resins
title_full_unstemmed Flexural and diametral tensile strength of composite resins
title_sort Flexural and diametral tensile strength of composite resins
author Della Bona,Álvaro
author_facet Della Bona,Álvaro
Benetti,Paula
Borba,Márcia
Cecchetti,Dileta
author_role author
author2 Benetti,Paula
Borba,Márcia
Cecchetti,Dileta
author2_role author
author
author
dc.contributor.author.fl_str_mv Della Bona,Álvaro
Benetti,Paula
Borba,Márcia
Cecchetti,Dileta
dc.subject.por.fl_str_mv Composite resins
Tensile strength
Physical properties
topic Composite resins
Tensile strength
Physical properties
description This study evaluated the flexural strength (sf) and the diametral tensile strength (st) of light-cured composite resins, testing the hypothesis that there is a positive relation between these properties. Twenty specimens were fabricated for each material (Filtek Z250- 3M-Espe; AM- Amelogen, Ultradent; VE- Vit-l-escence, Ultradent; EX- Esthet-X, Dentsply/Caulk), following ISO 4049 and ANSI/ADA 27 specifications and the manufacturers’ instructions. For the st test, cylindrical shaped (4 mm x 6 mm) specimens (n = 10) were placed with their long axes perpendicular to the applied compressive load at a crosshead speed of 1.0 mm/min. The sf was measured using the 3-point bending test, in which bar shaped specimens (n = 10) were tested at a crosshead speed of 0.5 mm/min. Both tests were performed in a universal testing machine (EMIC 2000) recording the fracture load (N). Strength values (MPa) were calculated and statistically analyzed by ANOVA and Tukey (a = 0.05). The mean and standard deviation values (MPa) were Z250-45.06 ± 5.7; AM-35.61 ± 5.4; VE-34.45 ± 7.8; and EX-42.87 ± 6.6 for st; and Z250-126.52 ± 3.3; AM-87.75 ± 3.8; VE-104.66 ± 4.4; and EX-119.48 ± 2.1 for sf. EX and Z250 showed higher st and sf values than the other materials evaluated (p < 0.05), which followed a decreasing trend of mean values. The results confirmed the study hypothesis, showing a positive relation between the material properties examined.
publishDate 2008
dc.date.none.fl_str_mv 2008-03-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242008000100015
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242008000100015
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-83242008000100015
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.22 n.1 2008
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318321241161728