Quantification of Streptococcus mutans in Different Types of Ligature Wires and Elastomeric Chains

Detalhes bibliográficos
Autor(a) principal: Shirozaki,Mariana Umekita
Data de Publicação: 2017
Outros Autores: Ferreira,José Tarcísio Lima, Küchler,Erika Calvano, Matsumoto,Mírian Aiko Nakane, Aires,Carolina Patrícia, Nelson-Filho,Paulo, Romano,Fábio Lourenço
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402017000400498
Resumo: Abstract This study aimed to test the hypothesis that Streptococcus mutans contamination levels differ according to the type of the orthodontic ligature. Thirteen patients were selected. Each quadrant was randomly subjected to one of the following ligature-use protocols: I) elastomeric chain, II) steel ligature crossed over the archwire, III) steel ligature crossed under the archwire, and IV) steel ligature in a figure-eight pattern under the archwire. After seven days, the devices were removed and the Streptococcus mutans colony-forming unit count per mg of biofilm weight was determined. Twelve specimens (n=3) were also processed for scanning electron microscopy analysis. ANOVA and Tukey-Kramer test were used for comparisons to assess S. mutans differences between groups at a 5% significance level. There was no statistical difference in detectable levels of S. mutans among the groups (p=0.294). Scanning electron microscopy results showed abundant biofilms and microbial contamination in all groups. In conclusion, S. mutans contamination levels are similar in the different orthodontic ligatures.
id FUNORP-1_1aa2798a9f6e19b18c635fde96893124
oai_identifier_str oai:scielo:S0103-64402017000400498
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Quantification of Streptococcus mutans in Different Types of Ligature Wires and Elastomeric ChainsStreptococcus mutansbiofilmorthodontic.Abstract This study aimed to test the hypothesis that Streptococcus mutans contamination levels differ according to the type of the orthodontic ligature. Thirteen patients were selected. Each quadrant was randomly subjected to one of the following ligature-use protocols: I) elastomeric chain, II) steel ligature crossed over the archwire, III) steel ligature crossed under the archwire, and IV) steel ligature in a figure-eight pattern under the archwire. After seven days, the devices were removed and the Streptococcus mutans colony-forming unit count per mg of biofilm weight was determined. Twelve specimens (n=3) were also processed for scanning electron microscopy analysis. ANOVA and Tukey-Kramer test were used for comparisons to assess S. mutans differences between groups at a 5% significance level. There was no statistical difference in detectable levels of S. mutans among the groups (p=0.294). Scanning electron microscopy results showed abundant biofilms and microbial contamination in all groups. In conclusion, S. mutans contamination levels are similar in the different orthodontic ligatures.Fundação Odontológica de Ribeirão Preto2017-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402017000400498Brazilian Dental Journal v.28 n.4 2017reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/0103-6440201601401info:eu-repo/semantics/openAccessShirozaki,Mariana UmekitaFerreira,José Tarcísio LimaKüchler,Erika CalvanoMatsumoto,Mírian Aiko NakaneAires,Carolina PatríciaNelson-Filho,PauloRomano,Fábio Lourençoeng2017-11-08T00:00:00Zoai:scielo:S0103-64402017000400498Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2017-11-08T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Quantification of Streptococcus mutans in Different Types of Ligature Wires and Elastomeric Chains
title Quantification of Streptococcus mutans in Different Types of Ligature Wires and Elastomeric Chains
spellingShingle Quantification of Streptococcus mutans in Different Types of Ligature Wires and Elastomeric Chains
Shirozaki,Mariana Umekita
Streptococcus mutans
biofilm
orthodontic.
title_short Quantification of Streptococcus mutans in Different Types of Ligature Wires and Elastomeric Chains
title_full Quantification of Streptococcus mutans in Different Types of Ligature Wires and Elastomeric Chains
title_fullStr Quantification of Streptococcus mutans in Different Types of Ligature Wires and Elastomeric Chains
title_full_unstemmed Quantification of Streptococcus mutans in Different Types of Ligature Wires and Elastomeric Chains
title_sort Quantification of Streptococcus mutans in Different Types of Ligature Wires and Elastomeric Chains
author Shirozaki,Mariana Umekita
author_facet Shirozaki,Mariana Umekita
Ferreira,José Tarcísio Lima
Küchler,Erika Calvano
Matsumoto,Mírian Aiko Nakane
Aires,Carolina Patrícia
Nelson-Filho,Paulo
Romano,Fábio Lourenço
author_role author
author2 Ferreira,José Tarcísio Lima
Küchler,Erika Calvano
Matsumoto,Mírian Aiko Nakane
Aires,Carolina Patrícia
Nelson-Filho,Paulo
Romano,Fábio Lourenço
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Shirozaki,Mariana Umekita
Ferreira,José Tarcísio Lima
Küchler,Erika Calvano
Matsumoto,Mírian Aiko Nakane
Aires,Carolina Patrícia
Nelson-Filho,Paulo
Romano,Fábio Lourenço
dc.subject.por.fl_str_mv Streptococcus mutans
biofilm
orthodontic.
topic Streptococcus mutans
biofilm
orthodontic.
description Abstract This study aimed to test the hypothesis that Streptococcus mutans contamination levels differ according to the type of the orthodontic ligature. Thirteen patients were selected. Each quadrant was randomly subjected to one of the following ligature-use protocols: I) elastomeric chain, II) steel ligature crossed over the archwire, III) steel ligature crossed under the archwire, and IV) steel ligature in a figure-eight pattern under the archwire. After seven days, the devices were removed and the Streptococcus mutans colony-forming unit count per mg of biofilm weight was determined. Twelve specimens (n=3) were also processed for scanning electron microscopy analysis. ANOVA and Tukey-Kramer test were used for comparisons to assess S. mutans differences between groups at a 5% significance level. There was no statistical difference in detectable levels of S. mutans among the groups (p=0.294). Scanning electron microscopy results showed abundant biofilms and microbial contamination in all groups. In conclusion, S. mutans contamination levels are similar in the different orthodontic ligatures.
publishDate 2017
dc.date.none.fl_str_mv 2017-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402017000400498
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402017000400498
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0103-6440201601401
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.28 n.4 2017
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204094833098752