Comparative study of tubular diameter and quantity for human and bovine dentin at different depths
Autor(a) principal: | |
---|---|
Data de Publicação: | 2009 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Dental Journal |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402009000400003 |
Resumo: | This study compared the tubular dimensions and distribution of human and bovine dentin. Ten human molars and 10 bovine incisors were ground with a high-speed handpiece to obtain 3 sections at different dentin depths (superficial, middle and deep). The specimens were sputter-coated with gold to be examined under scanning electron microscopy (SEM). Three SEM micrographs were recorded randomly for each dentin depth. The number of tubules was counted and the diameter of 5 tubules selected at random was measured in each SEM micrograph. Data were analyzed statistically by ANOVA and Tukey's test (a=0.05). In bovine teeth, superficial dentin (4.21 μm) and middle dentin (3.98 μm) had a significantly greater (p<0.05) diameter than deep dentin (3.14 μm) tubules. In human teeth, superficial dentin tubule diameter (2.42 μm) was significantly smaller (p<0.05) than deep dentin (2.99 μm) and middle dentin (2.94 μm) tubule diameters, which did not differ significantly from each other (p>0.05). The number of tubules per square millimiter, regardless of the region, was significantly greater in human dentin (22,329) than in bovine dentin (15,964). There was a clear difference in tubule structure and morphology between human and bovine dentin. |
id |
FUNORP-1_47e3c8b27ce764e854e369bdff75a78a |
---|---|
oai_identifier_str |
oai:scielo:S0103-64402009000400003 |
network_acronym_str |
FUNORP-1 |
network_name_str |
Brazilian Dental Journal |
repository_id_str |
|
spelling |
Comparative study of tubular diameter and quantity for human and bovine dentin at different depthsdentintubuleshumanbovinemorphologyThis study compared the tubular dimensions and distribution of human and bovine dentin. Ten human molars and 10 bovine incisors were ground with a high-speed handpiece to obtain 3 sections at different dentin depths (superficial, middle and deep). The specimens were sputter-coated with gold to be examined under scanning electron microscopy (SEM). Three SEM micrographs were recorded randomly for each dentin depth. The number of tubules was counted and the diameter of 5 tubules selected at random was measured in each SEM micrograph. Data were analyzed statistically by ANOVA and Tukey's test (a=0.05). In bovine teeth, superficial dentin (4.21 μm) and middle dentin (3.98 μm) had a significantly greater (p<0.05) diameter than deep dentin (3.14 μm) tubules. In human teeth, superficial dentin tubule diameter (2.42 μm) was significantly smaller (p<0.05) than deep dentin (2.99 μm) and middle dentin (2.94 μm) tubule diameters, which did not differ significantly from each other (p>0.05). The number of tubules per square millimiter, regardless of the region, was significantly greater in human dentin (22,329) than in bovine dentin (15,964). There was a clear difference in tubule structure and morphology between human and bovine dentin.Fundação Odontológica de Ribeirão Preto2009-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402009000400003Brazilian Dental Journal v.20 n.4 2009reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402009000400003info:eu-repo/semantics/openAccessLopes,Murilo BaenaSinhoreti,Mário A. C.Gonini Júnior,AlcidesConsani,SimonidesMccabe,John F.eng2009-12-17T00:00:00Zoai:scielo:S0103-64402009000400003Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2009-12-17T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false |
dc.title.none.fl_str_mv |
Comparative study of tubular diameter and quantity for human and bovine dentin at different depths |
title |
Comparative study of tubular diameter and quantity for human and bovine dentin at different depths |
spellingShingle |
Comparative study of tubular diameter and quantity for human and bovine dentin at different depths Lopes,Murilo Baena dentin tubules human bovine morphology |
title_short |
Comparative study of tubular diameter and quantity for human and bovine dentin at different depths |
title_full |
Comparative study of tubular diameter and quantity for human and bovine dentin at different depths |
title_fullStr |
Comparative study of tubular diameter and quantity for human and bovine dentin at different depths |
title_full_unstemmed |
Comparative study of tubular diameter and quantity for human and bovine dentin at different depths |
title_sort |
Comparative study of tubular diameter and quantity for human and bovine dentin at different depths |
author |
Lopes,Murilo Baena |
author_facet |
Lopes,Murilo Baena Sinhoreti,Mário A. C. Gonini Júnior,Alcides Consani,Simonides Mccabe,John F. |
author_role |
author |
author2 |
Sinhoreti,Mário A. C. Gonini Júnior,Alcides Consani,Simonides Mccabe,John F. |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Lopes,Murilo Baena Sinhoreti,Mário A. C. Gonini Júnior,Alcides Consani,Simonides Mccabe,John F. |
dc.subject.por.fl_str_mv |
dentin tubules human bovine morphology |
topic |
dentin tubules human bovine morphology |
description |
This study compared the tubular dimensions and distribution of human and bovine dentin. Ten human molars and 10 bovine incisors were ground with a high-speed handpiece to obtain 3 sections at different dentin depths (superficial, middle and deep). The specimens were sputter-coated with gold to be examined under scanning electron microscopy (SEM). Three SEM micrographs were recorded randomly for each dentin depth. The number of tubules was counted and the diameter of 5 tubules selected at random was measured in each SEM micrograph. Data were analyzed statistically by ANOVA and Tukey's test (a=0.05). In bovine teeth, superficial dentin (4.21 μm) and middle dentin (3.98 μm) had a significantly greater (p<0.05) diameter than deep dentin (3.14 μm) tubules. In human teeth, superficial dentin tubule diameter (2.42 μm) was significantly smaller (p<0.05) than deep dentin (2.99 μm) and middle dentin (2.94 μm) tubule diameters, which did not differ significantly from each other (p>0.05). The number of tubules per square millimiter, regardless of the region, was significantly greater in human dentin (22,329) than in bovine dentin (15,964). There was a clear difference in tubule structure and morphology between human and bovine dentin. |
publishDate |
2009 |
dc.date.none.fl_str_mv |
2009-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402009000400003 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402009000400003 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0103-64402009000400003 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
dc.source.none.fl_str_mv |
Brazilian Dental Journal v.20 n.4 2009 reponame:Brazilian Dental Journal instname:Fundação Odontológica de Ribeirão Preto (FUNORP) instacron:FUNORP |
instname_str |
Fundação Odontológica de Ribeirão Preto (FUNORP) |
instacron_str |
FUNORP |
institution |
FUNORP |
reponame_str |
Brazilian Dental Journal |
collection |
Brazilian Dental Journal |
repository.name.fl_str_mv |
Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP) |
repository.mail.fl_str_mv |
bdj@forp.usp.br||sergio@fosjc.unesp.br |
_version_ |
1754204090999504896 |