Linear and Angular Deviations of Implants Placed in Experimental Casts with Stereolithographic Drill Guides Fixed by O'ring Ortho Implant Devices
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Dental Journal |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402013000400391 |
Resumo: | The aim of this study was to evaluate whether the introduction of a device, resulting from the combination of an o'ring attachment with an orthodontic implant (o'ring ortho implant, O'ROI), to affix the surgical template of CAD/CAM-guided implant surgery contribute to minimizing the deviations in the position and inclination of implants at the time of their placement. Ten models simulating bone tissue were fabricated and randomly divided into 2 groups: 5 with the scanning and surgical template of the usual technique, representing the Control Group (C), and 5 with scanning and surgical templates fixed by o'ring ortho implants (O'ROI), representing the Test Group (T). Forty implants measuring 4×11 mm were placed in the groups, using the respective templates. The results were evaluated by the fusion of CT images of the planned and placed implants. The locations and axes were compared. There were no statistically significant differences for the angular (Tukey's test F = 1.06 and p = 0. 3124) and linear (ANOVA F = 2.54 and p = 0.11) deviations. However, the angular values of Group T showed a lower standard deviation in comparison with those of Group C. The use of o'ring ortho implants (O'ROI) is able to minimize the angular and linear deviation of implants at the time of their placement. |
id |
FUNORP-1_50f46b7cea2906b06dede436cc700f2f |
---|---|
oai_identifier_str |
oai:scielo:S0103-64402013000400391 |
network_acronym_str |
FUNORP-1 |
network_name_str |
Brazilian Dental Journal |
repository_id_str |
|
spelling |
Linear and Angular Deviations of Implants Placed in Experimental Casts with Stereolithographic Drill Guides Fixed by O'ring Ortho Implant Devicesdental implantscomputer-assisted surgerycomputed tomographyThe aim of this study was to evaluate whether the introduction of a device, resulting from the combination of an o'ring attachment with an orthodontic implant (o'ring ortho implant, O'ROI), to affix the surgical template of CAD/CAM-guided implant surgery contribute to minimizing the deviations in the position and inclination of implants at the time of their placement. Ten models simulating bone tissue were fabricated and randomly divided into 2 groups: 5 with the scanning and surgical template of the usual technique, representing the Control Group (C), and 5 with scanning and surgical templates fixed by o'ring ortho implants (O'ROI), representing the Test Group (T). Forty implants measuring 4×11 mm were placed in the groups, using the respective templates. The results were evaluated by the fusion of CT images of the planned and placed implants. The locations and axes were compared. There were no statistically significant differences for the angular (Tukey's test F = 1.06 and p = 0. 3124) and linear (ANOVA F = 2.54 and p = 0.11) deviations. However, the angular values of Group T showed a lower standard deviation in comparison with those of Group C. The use of o'ring ortho implants (O'ROI) is able to minimize the angular and linear deviation of implants at the time of their placement.Fundação Odontológica de Ribeirão Preto2013-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402013000400391Brazilian Dental Journal v.24 n.4 2013reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/0103-6440201302012info:eu-repo/semantics/openAccessNovellino,Marcelo MicheleSesma,NewtonLagana,Dalva CruzFerrari,Glaiseng2013-10-16T00:00:00Zoai:scielo:S0103-64402013000400391Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2013-10-16T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false |
dc.title.none.fl_str_mv |
Linear and Angular Deviations of Implants Placed in Experimental Casts with Stereolithographic Drill Guides Fixed by O'ring Ortho Implant Devices |
title |
Linear and Angular Deviations of Implants Placed in Experimental Casts with Stereolithographic Drill Guides Fixed by O'ring Ortho Implant Devices |
spellingShingle |
Linear and Angular Deviations of Implants Placed in Experimental Casts with Stereolithographic Drill Guides Fixed by O'ring Ortho Implant Devices Novellino,Marcelo Michele dental implants computer-assisted surgery computed tomography |
title_short |
Linear and Angular Deviations of Implants Placed in Experimental Casts with Stereolithographic Drill Guides Fixed by O'ring Ortho Implant Devices |
title_full |
Linear and Angular Deviations of Implants Placed in Experimental Casts with Stereolithographic Drill Guides Fixed by O'ring Ortho Implant Devices |
title_fullStr |
Linear and Angular Deviations of Implants Placed in Experimental Casts with Stereolithographic Drill Guides Fixed by O'ring Ortho Implant Devices |
title_full_unstemmed |
Linear and Angular Deviations of Implants Placed in Experimental Casts with Stereolithographic Drill Guides Fixed by O'ring Ortho Implant Devices |
title_sort |
Linear and Angular Deviations of Implants Placed in Experimental Casts with Stereolithographic Drill Guides Fixed by O'ring Ortho Implant Devices |
author |
Novellino,Marcelo Michele |
author_facet |
Novellino,Marcelo Michele Sesma,Newton Lagana,Dalva Cruz Ferrari,Glais |
author_role |
author |
author2 |
Sesma,Newton Lagana,Dalva Cruz Ferrari,Glais |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Novellino,Marcelo Michele Sesma,Newton Lagana,Dalva Cruz Ferrari,Glais |
dc.subject.por.fl_str_mv |
dental implants computer-assisted surgery computed tomography |
topic |
dental implants computer-assisted surgery computed tomography |
description |
The aim of this study was to evaluate whether the introduction of a device, resulting from the combination of an o'ring attachment with an orthodontic implant (o'ring ortho implant, O'ROI), to affix the surgical template of CAD/CAM-guided implant surgery contribute to minimizing the deviations in the position and inclination of implants at the time of their placement. Ten models simulating bone tissue were fabricated and randomly divided into 2 groups: 5 with the scanning and surgical template of the usual technique, representing the Control Group (C), and 5 with scanning and surgical templates fixed by o'ring ortho implants (O'ROI), representing the Test Group (T). Forty implants measuring 4×11 mm were placed in the groups, using the respective templates. The results were evaluated by the fusion of CT images of the planned and placed implants. The locations and axes were compared. There were no statistically significant differences for the angular (Tukey's test F = 1.06 and p = 0. 3124) and linear (ANOVA F = 2.54 and p = 0.11) deviations. However, the angular values of Group T showed a lower standard deviation in comparison with those of Group C. The use of o'ring ortho implants (O'ROI) is able to minimize the angular and linear deviation of implants at the time of their placement. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402013000400391 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402013000400391 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/0103-6440201302012 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
dc.source.none.fl_str_mv |
Brazilian Dental Journal v.24 n.4 2013 reponame:Brazilian Dental Journal instname:Fundação Odontológica de Ribeirão Preto (FUNORP) instacron:FUNORP |
instname_str |
Fundação Odontológica de Ribeirão Preto (FUNORP) |
instacron_str |
FUNORP |
institution |
FUNORP |
reponame_str |
Brazilian Dental Journal |
collection |
Brazilian Dental Journal |
repository.name.fl_str_mv |
Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP) |
repository.mail.fl_str_mv |
bdj@forp.usp.br||sergio@fosjc.unesp.br |
_version_ |
1754204092691906560 |