Influence of Temporary Cements on the Bond Strength of Self-Adhesive Cement to the Metal Coronal Substrate

Detalhes bibliográficos
Autor(a) principal: Peixoto,Raniel Fernandes
Data de Publicação: 2015
Outros Autores: Aguiar,Caio Rocha de, Jacob,Eduardo Santana, Macedo,Ana Paula, Mattos,Maria da Gloria Chiarello de, Antunes,Rossana Pereira de Almeida
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000600637
Resumo: This research evaluated the influence of temporary cements (eugenol-containing [EC] or eugenol-free [EF]) on the tensile strength of Ni-Cr copings fixed with self-adhesive resin cement to the metal coronal substrate. Thirty-six temporary crowns were divided into 4 groups (n=9) according to the temporary cements: Provy, Dentsply (eugenol-containing), Temp Cem, Vigodent (eugenol-containing), RelyX Temp NE, 3M ESPE (eugenol-free) and Temp Bond NE, Kerr Corp (eugenol-free). After 24 h of temporary cementation, tensile strength tests were performed in a universal testing machine at a crosshead speed of 0.5 mm/min and 1 kN (100 kgf) load cell. Afterwards, the cast metal cores were cleaned by scraping with curettes and air jet. Thirty-six Ni-Cr copings were cemented to the cast metal cores with self-adhesive resin cement (RelyX U200, 3M ESPE). Tensile strength tests were performed again. In the temporary cementation, Temp Bond NE (12.91±2.54) and Temp Cem (12.22±2.96) presented the highest values of tensile strength and were statistically similar to each other (p>0.05). Statistically significant difference (p<0.05) was observed only between Provy (164.44±31.23) and Temp Bond NE (88.48±21.83) after cementation of Ni-Cr copings with self-adhesive resin cement. In addition, Temp Cem (120.68±48.27) and RelyX Temp NE (103.04±26.09) showed intermediate tensile strength values. In conclusion, the Provy eugenol-containing temporary cement was associated with the highest bond strength among the resin cements when Ni-Cr copings were cemented to cast metal cores. However, the eugenol cannot be considered a determining factor in increased bond strength, since the other tested cements (1 eugenol-containing and 2 eugenol-free) were similar.
id FUNORP-1_60fe133d48be9472dc75d2b98aeda611
oai_identifier_str oai:scielo:S0103-64402015000600637
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Influence of Temporary Cements on the Bond Strength of Self-Adhesive Cement to the Metal Coronal Substratedental prosthesistemporary cementsresin cementstensile strengthThis research evaluated the influence of temporary cements (eugenol-containing [EC] or eugenol-free [EF]) on the tensile strength of Ni-Cr copings fixed with self-adhesive resin cement to the metal coronal substrate. Thirty-six temporary crowns were divided into 4 groups (n=9) according to the temporary cements: Provy, Dentsply (eugenol-containing), Temp Cem, Vigodent (eugenol-containing), RelyX Temp NE, 3M ESPE (eugenol-free) and Temp Bond NE, Kerr Corp (eugenol-free). After 24 h of temporary cementation, tensile strength tests were performed in a universal testing machine at a crosshead speed of 0.5 mm/min and 1 kN (100 kgf) load cell. Afterwards, the cast metal cores were cleaned by scraping with curettes and air jet. Thirty-six Ni-Cr copings were cemented to the cast metal cores with self-adhesive resin cement (RelyX U200, 3M ESPE). Tensile strength tests were performed again. In the temporary cementation, Temp Bond NE (12.91±2.54) and Temp Cem (12.22±2.96) presented the highest values of tensile strength and were statistically similar to each other (p>0.05). Statistically significant difference (p<0.05) was observed only between Provy (164.44±31.23) and Temp Bond NE (88.48±21.83) after cementation of Ni-Cr copings with self-adhesive resin cement. In addition, Temp Cem (120.68±48.27) and RelyX Temp NE (103.04±26.09) showed intermediate tensile strength values. In conclusion, the Provy eugenol-containing temporary cement was associated with the highest bond strength among the resin cements when Ni-Cr copings were cemented to cast metal cores. However, the eugenol cannot be considered a determining factor in increased bond strength, since the other tested cements (1 eugenol-containing and 2 eugenol-free) were similar.Fundação Odontológica de Ribeirão Preto2015-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000600637Brazilian Dental Journal v.26 n.6 2015reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/0103-6440201300362info:eu-repo/semantics/openAccessPeixoto,Raniel FernandesAguiar,Caio Rocha deJacob,Eduardo SantanaMacedo,Ana PaulaMattos,Maria da Gloria Chiarello deAntunes,Rossana Pereira de Almeidaeng2015-12-22T00:00:00Zoai:scielo:S0103-64402015000600637Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2015-12-22T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Influence of Temporary Cements on the Bond Strength of Self-Adhesive Cement to the Metal Coronal Substrate
title Influence of Temporary Cements on the Bond Strength of Self-Adhesive Cement to the Metal Coronal Substrate
spellingShingle Influence of Temporary Cements on the Bond Strength of Self-Adhesive Cement to the Metal Coronal Substrate
Peixoto,Raniel Fernandes
dental prosthesis
temporary cements
resin cements
tensile strength
title_short Influence of Temporary Cements on the Bond Strength of Self-Adhesive Cement to the Metal Coronal Substrate
title_full Influence of Temporary Cements on the Bond Strength of Self-Adhesive Cement to the Metal Coronal Substrate
title_fullStr Influence of Temporary Cements on the Bond Strength of Self-Adhesive Cement to the Metal Coronal Substrate
title_full_unstemmed Influence of Temporary Cements on the Bond Strength of Self-Adhesive Cement to the Metal Coronal Substrate
title_sort Influence of Temporary Cements on the Bond Strength of Self-Adhesive Cement to the Metal Coronal Substrate
author Peixoto,Raniel Fernandes
author_facet Peixoto,Raniel Fernandes
Aguiar,Caio Rocha de
Jacob,Eduardo Santana
Macedo,Ana Paula
Mattos,Maria da Gloria Chiarello de
Antunes,Rossana Pereira de Almeida
author_role author
author2 Aguiar,Caio Rocha de
Jacob,Eduardo Santana
Macedo,Ana Paula
Mattos,Maria da Gloria Chiarello de
Antunes,Rossana Pereira de Almeida
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Peixoto,Raniel Fernandes
Aguiar,Caio Rocha de
Jacob,Eduardo Santana
Macedo,Ana Paula
Mattos,Maria da Gloria Chiarello de
Antunes,Rossana Pereira de Almeida
dc.subject.por.fl_str_mv dental prosthesis
temporary cements
resin cements
tensile strength
topic dental prosthesis
temporary cements
resin cements
tensile strength
description This research evaluated the influence of temporary cements (eugenol-containing [EC] or eugenol-free [EF]) on the tensile strength of Ni-Cr copings fixed with self-adhesive resin cement to the metal coronal substrate. Thirty-six temporary crowns were divided into 4 groups (n=9) according to the temporary cements: Provy, Dentsply (eugenol-containing), Temp Cem, Vigodent (eugenol-containing), RelyX Temp NE, 3M ESPE (eugenol-free) and Temp Bond NE, Kerr Corp (eugenol-free). After 24 h of temporary cementation, tensile strength tests were performed in a universal testing machine at a crosshead speed of 0.5 mm/min and 1 kN (100 kgf) load cell. Afterwards, the cast metal cores were cleaned by scraping with curettes and air jet. Thirty-six Ni-Cr copings were cemented to the cast metal cores with self-adhesive resin cement (RelyX U200, 3M ESPE). Tensile strength tests were performed again. In the temporary cementation, Temp Bond NE (12.91±2.54) and Temp Cem (12.22±2.96) presented the highest values of tensile strength and were statistically similar to each other (p>0.05). Statistically significant difference (p<0.05) was observed only between Provy (164.44±31.23) and Temp Bond NE (88.48±21.83) after cementation of Ni-Cr copings with self-adhesive resin cement. In addition, Temp Cem (120.68±48.27) and RelyX Temp NE (103.04±26.09) showed intermediate tensile strength values. In conclusion, the Provy eugenol-containing temporary cement was associated with the highest bond strength among the resin cements when Ni-Cr copings were cemented to cast metal cores. However, the eugenol cannot be considered a determining factor in increased bond strength, since the other tested cements (1 eugenol-containing and 2 eugenol-free) were similar.
publishDate 2015
dc.date.none.fl_str_mv 2015-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000600637
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000600637
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0103-6440201300362
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.26 n.6 2015
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204093936566272