Biocompatibility of sealers used in apical surgery: a histological study in rat subcutaneous tissue

Detalhes bibliográficos
Autor(a) principal: Cunha,Suely Aparecida
Data de Publicação: 2011
Outros Autores: Rached Jr,Fuad Jacob Abi, Alfredo,Edson, León,Jorge Esquiche, Perez,Danyel Elias da Cruz
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000400007
Resumo: The aim of this study was to evaluate the biocompatibility of sealers used in apical surgery in rat subcutaneous tissue. Sterile polyethylene tubes were filled with the following sealers: Sealapex, Sealapex with addition of zinc oxide, Sealer 26, Sealer 26 with thicker consistency (greater powder-to-resin ratio) and White MTA. The tubes were implanted in the dorsum of male rats and after 7, 21 and 42 days, the animals were killed, obtaining 5 specimens for each sealer in each evaluation period. The lateral surface of the tube was used as negative control. The inflammatory reaction to contact with the sealers was classified as absent, mild, moderate and severe. At 7 days, all sealers caused similar inflammatory reactions in the connective tissue of the animals, with most specimens presenting a moderate to intense chronic inflammatory reaction, with presence of multinucleated giant cells. At 21 days, Sealer 26 and Sealer 26 with thicker consistency presented more intense inflammatory reaction (p=0.004), whereas after 42 days, the inflammatory reaction ranged from absent to mild with statistically similar results for both materials (p=0.08). Except for MTA, all sealers presented foreign-body granulomatous reaction at 42 days. All sealers but Sealapex presented a statistically significant decrease of the inflammatory reaction over time. In conclusion, all sealers caused moderate to severe inflammation in the earlier evaluation period. However, Sealer 26 and Sealer 26 with thicker consistency caused more intense inflammatory reactions after 21 days of contact with the tissues and no granulomatous reaction was observed for MTA at the final period of analysis.
id FUNORP-1_815e05c916e813c9c67923409ef719b7
oai_identifier_str oai:scielo:S0103-64402011000400007
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Biocompatibility of sealers used in apical surgery: a histological study in rat subcutaneous tissuebiocompatibilityMTASealapexzinc oxideSealer 26The aim of this study was to evaluate the biocompatibility of sealers used in apical surgery in rat subcutaneous tissue. Sterile polyethylene tubes were filled with the following sealers: Sealapex, Sealapex with addition of zinc oxide, Sealer 26, Sealer 26 with thicker consistency (greater powder-to-resin ratio) and White MTA. The tubes were implanted in the dorsum of male rats and after 7, 21 and 42 days, the animals were killed, obtaining 5 specimens for each sealer in each evaluation period. The lateral surface of the tube was used as negative control. The inflammatory reaction to contact with the sealers was classified as absent, mild, moderate and severe. At 7 days, all sealers caused similar inflammatory reactions in the connective tissue of the animals, with most specimens presenting a moderate to intense chronic inflammatory reaction, with presence of multinucleated giant cells. At 21 days, Sealer 26 and Sealer 26 with thicker consistency presented more intense inflammatory reaction (p=0.004), whereas after 42 days, the inflammatory reaction ranged from absent to mild with statistically similar results for both materials (p=0.08). Except for MTA, all sealers presented foreign-body granulomatous reaction at 42 days. All sealers but Sealapex presented a statistically significant decrease of the inflammatory reaction over time. In conclusion, all sealers caused moderate to severe inflammation in the earlier evaluation period. However, Sealer 26 and Sealer 26 with thicker consistency caused more intense inflammatory reactions after 21 days of contact with the tissues and no granulomatous reaction was observed for MTA at the final period of analysis.Fundação Odontológica de Ribeirão Preto2011-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000400007Brazilian Dental Journal v.22 n.4 2011reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402011000400007info:eu-repo/semantics/openAccessCunha,Suely AparecidaRached Jr,Fuad Jacob AbiAlfredo,EdsonLeón,Jorge EsquichePerez,Danyel Elias da Cruzeng2011-08-12T00:00:00Zoai:scielo:S0103-64402011000400007Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2011-08-12T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Biocompatibility of sealers used in apical surgery: a histological study in rat subcutaneous tissue
title Biocompatibility of sealers used in apical surgery: a histological study in rat subcutaneous tissue
spellingShingle Biocompatibility of sealers used in apical surgery: a histological study in rat subcutaneous tissue
Cunha,Suely Aparecida
biocompatibility
MTA
Sealapex
zinc oxide
Sealer 26
title_short Biocompatibility of sealers used in apical surgery: a histological study in rat subcutaneous tissue
title_full Biocompatibility of sealers used in apical surgery: a histological study in rat subcutaneous tissue
title_fullStr Biocompatibility of sealers used in apical surgery: a histological study in rat subcutaneous tissue
title_full_unstemmed Biocompatibility of sealers used in apical surgery: a histological study in rat subcutaneous tissue
title_sort Biocompatibility of sealers used in apical surgery: a histological study in rat subcutaneous tissue
author Cunha,Suely Aparecida
author_facet Cunha,Suely Aparecida
Rached Jr,Fuad Jacob Abi
Alfredo,Edson
León,Jorge Esquiche
Perez,Danyel Elias da Cruz
author_role author
author2 Rached Jr,Fuad Jacob Abi
Alfredo,Edson
León,Jorge Esquiche
Perez,Danyel Elias da Cruz
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Cunha,Suely Aparecida
Rached Jr,Fuad Jacob Abi
Alfredo,Edson
León,Jorge Esquiche
Perez,Danyel Elias da Cruz
dc.subject.por.fl_str_mv biocompatibility
MTA
Sealapex
zinc oxide
Sealer 26
topic biocompatibility
MTA
Sealapex
zinc oxide
Sealer 26
description The aim of this study was to evaluate the biocompatibility of sealers used in apical surgery in rat subcutaneous tissue. Sterile polyethylene tubes were filled with the following sealers: Sealapex, Sealapex with addition of zinc oxide, Sealer 26, Sealer 26 with thicker consistency (greater powder-to-resin ratio) and White MTA. The tubes were implanted in the dorsum of male rats and after 7, 21 and 42 days, the animals were killed, obtaining 5 specimens for each sealer in each evaluation period. The lateral surface of the tube was used as negative control. The inflammatory reaction to contact with the sealers was classified as absent, mild, moderate and severe. At 7 days, all sealers caused similar inflammatory reactions in the connective tissue of the animals, with most specimens presenting a moderate to intense chronic inflammatory reaction, with presence of multinucleated giant cells. At 21 days, Sealer 26 and Sealer 26 with thicker consistency presented more intense inflammatory reaction (p=0.004), whereas after 42 days, the inflammatory reaction ranged from absent to mild with statistically similar results for both materials (p=0.08). Except for MTA, all sealers presented foreign-body granulomatous reaction at 42 days. All sealers but Sealapex presented a statistically significant decrease of the inflammatory reaction over time. In conclusion, all sealers caused moderate to severe inflammation in the earlier evaluation period. However, Sealer 26 and Sealer 26 with thicker consistency caused more intense inflammatory reactions after 21 days of contact with the tissues and no granulomatous reaction was observed for MTA at the final period of analysis.
publishDate 2011
dc.date.none.fl_str_mv 2011-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000400007
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402011000400007
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-64402011000400007
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.22 n.4 2011
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204091799568384