Influence of shade and irradiation time on the hardness of composite resins

Detalhes bibliográficos
Autor(a) principal: Della Bona,Álvaro
Data de Publicação: 2007
Outros Autores: Rosa,Vinícius, Cecchetti,Dileta
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Dental Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402007000300010
Resumo: This study tested the following hypotheses: 1. increasing light irradiation time (IT) produces greater values of superficial hardness on different depths (0 and 3 mm); and 2. a dark shade composite (A3) needs longer IT than a light shade composite (A1) to produce similar hardness. Disk-shaped specimens (n=24 per shade) were fabricated using a 3-mm-thick increment of composite resin (Z100). Specimens were randomly assigned to 3 groups (n=8) according to the IT (400 mW/cm2) at the upper (U) surface: A1-10 and A3-10: 10 s; A1-20 and A3-20: 20 s; A1-40 and A3-40: 40 s. Specimens were stored in black lightproof containers at 37ºC for 24 h before indentation in a hardness tester. Three Vickers indentations were performed on the U and lower (L) surfaces of each specimen. The indent diagonals were measured and the hardness value calculated. The results were analyzed statistically by ANOVA and Tukey's test (alpha=0.05). Statistically significant differences were found between U and L surfaces of each composite shade-IT combination (p=0.0001) and among the ITs of same shade-surface combination (p=0.0001), except between groups A1-20U and A1-40U, confirming the study hypothesis 1 and partially rejecting the hypothesis 2.
id FUNORP-1_9abfd529d110f90ffc503ce4c7855d11
oai_identifier_str oai:scielo:S0103-64402007000300010
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Influence of shade and irradiation time on the hardness of composite resinsresin compositeshadehardnessirradiation timeThis study tested the following hypotheses: 1. increasing light irradiation time (IT) produces greater values of superficial hardness on different depths (0 and 3 mm); and 2. a dark shade composite (A3) needs longer IT than a light shade composite (A1) to produce similar hardness. Disk-shaped specimens (n=24 per shade) were fabricated using a 3-mm-thick increment of composite resin (Z100). Specimens were randomly assigned to 3 groups (n=8) according to the IT (400 mW/cm2) at the upper (U) surface: A1-10 and A3-10: 10 s; A1-20 and A3-20: 20 s; A1-40 and A3-40: 40 s. Specimens were stored in black lightproof containers at 37ºC for 24 h before indentation in a hardness tester. Three Vickers indentations were performed on the U and lower (L) surfaces of each specimen. The indent diagonals were measured and the hardness value calculated. The results were analyzed statistically by ANOVA and Tukey's test (alpha=0.05). Statistically significant differences were found between U and L surfaces of each composite shade-IT combination (p=0.0001) and among the ITs of same shade-surface combination (p=0.0001), except between groups A1-20U and A1-40U, confirming the study hypothesis 1 and partially rejecting the hypothesis 2.Fundação Odontológica de Ribeirão Preto2007-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402007000300010Brazilian Dental Journal v.18 n.3 2007reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402007000300010info:eu-repo/semantics/openAccessDella Bona,ÁlvaroRosa,ViníciusCecchetti,Diletaeng2008-01-02T00:00:00Zoai:scielo:S0103-64402007000300010Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2008-01-02T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Influence of shade and irradiation time on the hardness of composite resins
title Influence of shade and irradiation time on the hardness of composite resins
spellingShingle Influence of shade and irradiation time on the hardness of composite resins
Della Bona,Álvaro
resin composite
shade
hardness
irradiation time
title_short Influence of shade and irradiation time on the hardness of composite resins
title_full Influence of shade and irradiation time on the hardness of composite resins
title_fullStr Influence of shade and irradiation time on the hardness of composite resins
title_full_unstemmed Influence of shade and irradiation time on the hardness of composite resins
title_sort Influence of shade and irradiation time on the hardness of composite resins
author Della Bona,Álvaro
author_facet Della Bona,Álvaro
Rosa,Vinícius
Cecchetti,Dileta
author_role author
author2 Rosa,Vinícius
Cecchetti,Dileta
author2_role author
author
dc.contributor.author.fl_str_mv Della Bona,Álvaro
Rosa,Vinícius
Cecchetti,Dileta
dc.subject.por.fl_str_mv resin composite
shade
hardness
irradiation time
topic resin composite
shade
hardness
irradiation time
description This study tested the following hypotheses: 1. increasing light irradiation time (IT) produces greater values of superficial hardness on different depths (0 and 3 mm); and 2. a dark shade composite (A3) needs longer IT than a light shade composite (A1) to produce similar hardness. Disk-shaped specimens (n=24 per shade) were fabricated using a 3-mm-thick increment of composite resin (Z100). Specimens were randomly assigned to 3 groups (n=8) according to the IT (400 mW/cm2) at the upper (U) surface: A1-10 and A3-10: 10 s; A1-20 and A3-20: 20 s; A1-40 and A3-40: 40 s. Specimens were stored in black lightproof containers at 37ºC for 24 h before indentation in a hardness tester. Three Vickers indentations were performed on the U and lower (L) surfaces of each specimen. The indent diagonals were measured and the hardness value calculated. The results were analyzed statistically by ANOVA and Tukey's test (alpha=0.05). Statistically significant differences were found between U and L surfaces of each composite shade-IT combination (p=0.0001) and among the ITs of same shade-surface combination (p=0.0001), except between groups A1-20U and A1-40U, confirming the study hypothesis 1 and partially rejecting the hypothesis 2.
publishDate 2007
dc.date.none.fl_str_mv 2007-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402007000300010
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402007000300010
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-64402007000300010
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.18 n.3 2007
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204090536034304