Constructive Pathologies in Hotels: A Case Study
Autor(a) principal: | |
---|---|
Data de Publicação: | 2023 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Vetor (Online) |
Texto Completo: | https://periodicos.furg.br/vetor/article/view/15843 |
Resumo: | In the hotel industry, where constructive aesthetics are a differential for the success of the enterprise, diagnostic engineering is often used to treat pathological manifestations. Thus, the study of inspection methodology and discussion of pathological manifestations is fundamental for an adequate implementation of corrective actions, so that the minimum performance of the building and its systems are achieved, thus not compromising the useful life of the building, the safety and the users' comfort. The present work proposed a case study in two hotel buildings in the city of Rio Quente (Goiás) surveying the manifestations that occurred in their useful life, applying concepts of diagnostic engineering to propose solutions, that is, therapies for each of the identified manifestations. The methodology initially consisted of a literature review approach to support the proposed therapies. Data collection was carried out through technical reports, on-site visits and photographic records. A Monitoring Map was used to summarize the information collected. As a result, ten manifestations and a therapy proposal for each of them were presented. The work pointed out that in 80% of the cases the origin was associated with failures in the execution phase of the building, in 70% of the cases the cause was the humidity and the most frequent pathological manifestations, totaling 30% of the cases, were the cracks, fissures and cracks. |
id |
FURG-7_ed66efe431ed22b3da2fb293e8284b8e |
---|---|
oai_identifier_str |
oai:ojs.periodicos.furg.br:article/15843 |
network_acronym_str |
FURG-7 |
network_name_str |
Vetor (Online) |
repository_id_str |
|
spelling |
Constructive Pathologies in Hotels: A Case StudyPatologias Construtivas em Hotéis: Estudo de CasoPathologyConstructive FlawsMoistureCrackConstructionPathologiesCase StudyPatalogiaFalhas ConstrutivasUmidadeTrincaConstrução CivilPatologiasEstudo de CasoIn the hotel industry, where constructive aesthetics are a differential for the success of the enterprise, diagnostic engineering is often used to treat pathological manifestations. Thus, the study of inspection methodology and discussion of pathological manifestations is fundamental for an adequate implementation of corrective actions, so that the minimum performance of the building and its systems are achieved, thus not compromising the useful life of the building, the safety and the users' comfort. The present work proposed a case study in two hotel buildings in the city of Rio Quente (Goiás) surveying the manifestations that occurred in their useful life, applying concepts of diagnostic engineering to propose solutions, that is, therapies for each of the identified manifestations. The methodology initially consisted of a literature review approach to support the proposed therapies. Data collection was carried out through technical reports, on-site visits and photographic records. A Monitoring Map was used to summarize the information collected. As a result, ten manifestations and a therapy proposal for each of them were presented. The work pointed out that in 80% of the cases the origin was associated with failures in the execution phase of the building, in 70% of the cases the cause was the humidity and the most frequent pathological manifestations, totaling 30% of the cases, were the cracks, fissures and cracks.No ramo hoteleiro, em que a estética construtiva é um diferencial para o êxito do empreendimento, frequentemente a engenharia diagnóstica é acionada para tratar manifestações patológicas. Assim o estudo de metodologia de inspeção e discussão das manifestações patológicas é fundamental para uma adequada implementação de ações corretivas, de forma que o desempenho mínimo da edificação e dos seus sistemas sejam atingidos, não comprometendo assim a vida útil da edificação, a segurança e o conforto dos usuários. O presente trabalho propôs um estudo de caso em dois edifícios hoteleiros da cidade de Rio Quente (Goiás) levantando as manifestações ocorridas na sua vida útil, aplicando conceitos da engenharia diagnóstica para propor soluções, ou seja, terapias para cada uma das manifestações identificadas. A metodologia consistiu inicialmente em uma abordagem de revisão bibliográfica, para embasar as terapias propostas. Foi realizado uma coleta de dados através de laudos técnicos, visitas in loco e registros fotográfico. Foi utilizado um Mapa de Acompanhamento para sintetizar as informações levantadas. Como resultados, apresentou-se dez manifestações e proposta de terapia para cada uma delas. O trabalhou apontou que em 80% dos casos a origem estava associada a falhas na fase de execução do edifício, em 70% dos casos a causa foi a umidade e as manifestações patológicas mais frequentes, totalizando 30% dos casos, foram as trincas, fissuras e rachaduras.Universidade Federal do Rio Grande2023-12-23info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://periodicos.furg.br/vetor/article/view/1584310.14295/vetor.v33i2.15843VETOR - Journal of Exact Sciences and Engineering; Vol. 33 No. 2 (2023); 118-127VETOR - Revista de Ciências Exatas e Engenharias; v. 33 n. 2 (2023); 118-1272358-34520102-7352reponame:Vetor (Online)instname:Universidade Federal do Rio Grande (FURG)instacron:FURGporhttps://periodicos.furg.br/vetor/article/view/15843/10486Copyright (c) 2023 VETOR - Revista de Ciências Exatas e Engenhariasinfo:eu-repo/semantics/openAccessGomes, Elen Stephane FernandesMartins, Taline CarvalhoCruz Júnior, Aleones José dada Cruz, Daniel Magalhães2023-12-23T15:36:43Zoai:ojs.periodicos.furg.br:article/15843Revistahttps://periodicos.furg.br/vetorPUBhttps://periodicos.furg.br/vetor/oaigmplatt@furg.br2358-34520102-7352opendoar:2023-12-23T15:36:43Vetor (Online) - Universidade Federal do Rio Grande (FURG)false |
dc.title.none.fl_str_mv |
Constructive Pathologies in Hotels: A Case Study Patologias Construtivas em Hotéis: Estudo de Caso |
title |
Constructive Pathologies in Hotels: A Case Study |
spellingShingle |
Constructive Pathologies in Hotels: A Case Study Gomes, Elen Stephane Fernandes Pathology Constructive Flaws Moisture Crack Construction Pathologies Case Study Patalogia Falhas Construtivas Umidade Trinca Construção Civil Patologias Estudo de Caso |
title_short |
Constructive Pathologies in Hotels: A Case Study |
title_full |
Constructive Pathologies in Hotels: A Case Study |
title_fullStr |
Constructive Pathologies in Hotels: A Case Study |
title_full_unstemmed |
Constructive Pathologies in Hotels: A Case Study |
title_sort |
Constructive Pathologies in Hotels: A Case Study |
author |
Gomes, Elen Stephane Fernandes |
author_facet |
Gomes, Elen Stephane Fernandes Martins, Taline Carvalho Cruz Júnior, Aleones José da da Cruz, Daniel Magalhães |
author_role |
author |
author2 |
Martins, Taline Carvalho Cruz Júnior, Aleones José da da Cruz, Daniel Magalhães |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Gomes, Elen Stephane Fernandes Martins, Taline Carvalho Cruz Júnior, Aleones José da da Cruz, Daniel Magalhães |
dc.subject.por.fl_str_mv |
Pathology Constructive Flaws Moisture Crack Construction Pathologies Case Study Patalogia Falhas Construtivas Umidade Trinca Construção Civil Patologias Estudo de Caso |
topic |
Pathology Constructive Flaws Moisture Crack Construction Pathologies Case Study Patalogia Falhas Construtivas Umidade Trinca Construção Civil Patologias Estudo de Caso |
description |
In the hotel industry, where constructive aesthetics are a differential for the success of the enterprise, diagnostic engineering is often used to treat pathological manifestations. Thus, the study of inspection methodology and discussion of pathological manifestations is fundamental for an adequate implementation of corrective actions, so that the minimum performance of the building and its systems are achieved, thus not compromising the useful life of the building, the safety and the users' comfort. The present work proposed a case study in two hotel buildings in the city of Rio Quente (Goiás) surveying the manifestations that occurred in their useful life, applying concepts of diagnostic engineering to propose solutions, that is, therapies for each of the identified manifestations. The methodology initially consisted of a literature review approach to support the proposed therapies. Data collection was carried out through technical reports, on-site visits and photographic records. A Monitoring Map was used to summarize the information collected. As a result, ten manifestations and a therapy proposal for each of them were presented. The work pointed out that in 80% of the cases the origin was associated with failures in the execution phase of the building, in 70% of the cases the cause was the humidity and the most frequent pathological manifestations, totaling 30% of the cases, were the cracks, fissures and cracks. |
publishDate |
2023 |
dc.date.none.fl_str_mv |
2023-12-23 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://periodicos.furg.br/vetor/article/view/15843 10.14295/vetor.v33i2.15843 |
url |
https://periodicos.furg.br/vetor/article/view/15843 |
identifier_str_mv |
10.14295/vetor.v33i2.15843 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://periodicos.furg.br/vetor/article/view/15843/10486 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2023 VETOR - Revista de Ciências Exatas e Engenharias info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2023 VETOR - Revista de Ciências Exatas e Engenharias |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal do Rio Grande |
publisher.none.fl_str_mv |
Universidade Federal do Rio Grande |
dc.source.none.fl_str_mv |
VETOR - Journal of Exact Sciences and Engineering; Vol. 33 No. 2 (2023); 118-127 VETOR - Revista de Ciências Exatas e Engenharias; v. 33 n. 2 (2023); 118-127 2358-3452 0102-7352 reponame:Vetor (Online) instname:Universidade Federal do Rio Grande (FURG) instacron:FURG |
instname_str |
Universidade Federal do Rio Grande (FURG) |
instacron_str |
FURG |
institution |
FURG |
reponame_str |
Vetor (Online) |
collection |
Vetor (Online) |
repository.name.fl_str_mv |
Vetor (Online) - Universidade Federal do Rio Grande (FURG) |
repository.mail.fl_str_mv |
gmplatt@furg.br |
_version_ |
1797041760290996224 |