IS DIGITAL RECTAL EXAM RELIABLE IN GRADING ANAL SPHINCTER DEFECTS?
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos de gastroenterologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032016000400240 |
Resumo: | ABSTRACT Background Anal sphincter tone is routinely assessed by digital rectal examination in patients with fecal incontinence, although its accuracy in detecting sphincter defects or separating competent from incompetent muscles has not been established. Objective In this setting, we aimed to evaluate the accuracy of digital rectal examination in grading anal defects in order to separate small from extensive cases as depicted on 3D endoanal ultrasound, using a scoring sphincter defect and correlate anal tone to anal pressures. Methods Women with fecal incontinence were divided into two groups: small or extensive defects according to the ultrasound scoring system. Sensitivity, specificity, positive and negative predictive values of digital rectal examination in grading global and external sphincter defects were calculated. Anal tone at digital rectal examination was compared to resting and incremental pressures. Results A cohort of 76 consecutive incontinent women were enrolled. The median Wexner score was 9. Sixty-eight showed sphincter defects on 3D endoanal ultrasound. Anal tone at digital rectal examination was considered abnormal in 62 cases. Abnormal digital rectal examination showed a sensitivity of 90%, specificity of 27.78% in distinguishing small from extensive defects of both sphincters. Five out of eight women with no sphincter defects had only abnormal squeeze tone at digital rectal examination. Abnormal squeeze tone at digital rectal examination had a sensitivity of 65.31% in distinguishing small from extensive external anal sphincter defects. Digital rectal examination sensitivity increased linearly from small to extensive external anal sphincter defects (P=0.001). Women with abnormal resting tone had lower resting pressures than women with normal tone at digital rectal examination (P=0.0001). Women with abnormal squeeze tone had lower incremental pressures than women with normal tone at digital rectal examination (P=0.017). Conclusion Digital rectal examination had good sensitivity and poor specificity in discerning small from severe global anal sphincter defects. Moreover, digital rectal examination had fair sensitivity and poor specificity in grading external anal sphincter defects, and its best accuracy was on complete external anal sphincter lesions. Anal resting and squeeze tone were correlated to anal pressures. |
id |
IBEPEGE-1_edfeb719a0f1092213d7234bfbc037d9 |
---|---|
oai_identifier_str |
oai:scielo:S0004-28032016000400240 |
network_acronym_str |
IBEPEGE-1 |
network_name_str |
Arquivos de gastroenterologia (Online) |
repository_id_str |
|
spelling |
IS DIGITAL RECTAL EXAM RELIABLE IN GRADING ANAL SPHINCTER DEFECTS?Digital rectal examinationFecal incontinenceUltrasonographyManometryAnal canal, physiologyABSTRACT Background Anal sphincter tone is routinely assessed by digital rectal examination in patients with fecal incontinence, although its accuracy in detecting sphincter defects or separating competent from incompetent muscles has not been established. Objective In this setting, we aimed to evaluate the accuracy of digital rectal examination in grading anal defects in order to separate small from extensive cases as depicted on 3D endoanal ultrasound, using a scoring sphincter defect and correlate anal tone to anal pressures. Methods Women with fecal incontinence were divided into two groups: small or extensive defects according to the ultrasound scoring system. Sensitivity, specificity, positive and negative predictive values of digital rectal examination in grading global and external sphincter defects were calculated. Anal tone at digital rectal examination was compared to resting and incremental pressures. Results A cohort of 76 consecutive incontinent women were enrolled. The median Wexner score was 9. Sixty-eight showed sphincter defects on 3D endoanal ultrasound. Anal tone at digital rectal examination was considered abnormal in 62 cases. Abnormal digital rectal examination showed a sensitivity of 90%, specificity of 27.78% in distinguishing small from extensive defects of both sphincters. Five out of eight women with no sphincter defects had only abnormal squeeze tone at digital rectal examination. Abnormal squeeze tone at digital rectal examination had a sensitivity of 65.31% in distinguishing small from extensive external anal sphincter defects. Digital rectal examination sensitivity increased linearly from small to extensive external anal sphincter defects (P=0.001). Women with abnormal resting tone had lower resting pressures than women with normal tone at digital rectal examination (P=0.0001). Women with abnormal squeeze tone had lower incremental pressures than women with normal tone at digital rectal examination (P=0.017). Conclusion Digital rectal examination had good sensitivity and poor specificity in discerning small from severe global anal sphincter defects. Moreover, digital rectal examination had fair sensitivity and poor specificity in grading external anal sphincter defects, and its best accuracy was on complete external anal sphincter lesions. Anal resting and squeeze tone were correlated to anal pressures.Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia e Outras Especialidades - IBEPEGE. 2016-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032016000400240Arquivos de Gastroenterologia v.53 n.4 2016reponame:Arquivos de gastroenterologia (Online)instname:Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologiainstacron:IBEPEGE10.1590/S0004-28032016000400006info:eu-repo/semantics/openAccessCOURA,Marcelo de Melo AndradeSILVA,Silvana MarquesALMEIDA,Romulo Medeiros deFORREST,Miles CastedoSOUSA,João Batistaeng2016-09-27T00:00:00Zoai:scielo:S0004-28032016000400240Revistahttp://www.scielo.br/aghttps://old.scielo.br/oai/scielo-oai.php||secretariaarqgastr@hospitaligesp.com.br1678-42190004-2803opendoar:2016-09-27T00:00Arquivos de gastroenterologia (Online) - Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologiafalse |
dc.title.none.fl_str_mv |
IS DIGITAL RECTAL EXAM RELIABLE IN GRADING ANAL SPHINCTER DEFECTS? |
title |
IS DIGITAL RECTAL EXAM RELIABLE IN GRADING ANAL SPHINCTER DEFECTS? |
spellingShingle |
IS DIGITAL RECTAL EXAM RELIABLE IN GRADING ANAL SPHINCTER DEFECTS? COURA,Marcelo de Melo Andrade Digital rectal examination Fecal incontinence Ultrasonography Manometry Anal canal, physiology |
title_short |
IS DIGITAL RECTAL EXAM RELIABLE IN GRADING ANAL SPHINCTER DEFECTS? |
title_full |
IS DIGITAL RECTAL EXAM RELIABLE IN GRADING ANAL SPHINCTER DEFECTS? |
title_fullStr |
IS DIGITAL RECTAL EXAM RELIABLE IN GRADING ANAL SPHINCTER DEFECTS? |
title_full_unstemmed |
IS DIGITAL RECTAL EXAM RELIABLE IN GRADING ANAL SPHINCTER DEFECTS? |
title_sort |
IS DIGITAL RECTAL EXAM RELIABLE IN GRADING ANAL SPHINCTER DEFECTS? |
author |
COURA,Marcelo de Melo Andrade |
author_facet |
COURA,Marcelo de Melo Andrade SILVA,Silvana Marques ALMEIDA,Romulo Medeiros de FORREST,Miles Castedo SOUSA,João Batista |
author_role |
author |
author2 |
SILVA,Silvana Marques ALMEIDA,Romulo Medeiros de FORREST,Miles Castedo SOUSA,João Batista |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
COURA,Marcelo de Melo Andrade SILVA,Silvana Marques ALMEIDA,Romulo Medeiros de FORREST,Miles Castedo SOUSA,João Batista |
dc.subject.por.fl_str_mv |
Digital rectal examination Fecal incontinence Ultrasonography Manometry Anal canal, physiology |
topic |
Digital rectal examination Fecal incontinence Ultrasonography Manometry Anal canal, physiology |
description |
ABSTRACT Background Anal sphincter tone is routinely assessed by digital rectal examination in patients with fecal incontinence, although its accuracy in detecting sphincter defects or separating competent from incompetent muscles has not been established. Objective In this setting, we aimed to evaluate the accuracy of digital rectal examination in grading anal defects in order to separate small from extensive cases as depicted on 3D endoanal ultrasound, using a scoring sphincter defect and correlate anal tone to anal pressures. Methods Women with fecal incontinence were divided into two groups: small or extensive defects according to the ultrasound scoring system. Sensitivity, specificity, positive and negative predictive values of digital rectal examination in grading global and external sphincter defects were calculated. Anal tone at digital rectal examination was compared to resting and incremental pressures. Results A cohort of 76 consecutive incontinent women were enrolled. The median Wexner score was 9. Sixty-eight showed sphincter defects on 3D endoanal ultrasound. Anal tone at digital rectal examination was considered abnormal in 62 cases. Abnormal digital rectal examination showed a sensitivity of 90%, specificity of 27.78% in distinguishing small from extensive defects of both sphincters. Five out of eight women with no sphincter defects had only abnormal squeeze tone at digital rectal examination. Abnormal squeeze tone at digital rectal examination had a sensitivity of 65.31% in distinguishing small from extensive external anal sphincter defects. Digital rectal examination sensitivity increased linearly from small to extensive external anal sphincter defects (P=0.001). Women with abnormal resting tone had lower resting pressures than women with normal tone at digital rectal examination (P=0.0001). Women with abnormal squeeze tone had lower incremental pressures than women with normal tone at digital rectal examination (P=0.017). Conclusion Digital rectal examination had good sensitivity and poor specificity in discerning small from severe global anal sphincter defects. Moreover, digital rectal examination had fair sensitivity and poor specificity in grading external anal sphincter defects, and its best accuracy was on complete external anal sphincter lesions. Anal resting and squeeze tone were correlated to anal pressures. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032016000400240 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-28032016000400240 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0004-28032016000400006 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia e Outras Especialidades - IBEPEGE. |
publisher.none.fl_str_mv |
Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia e Outras Especialidades - IBEPEGE. |
dc.source.none.fl_str_mv |
Arquivos de Gastroenterologia v.53 n.4 2016 reponame:Arquivos de gastroenterologia (Online) instname:Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia instacron:IBEPEGE |
instname_str |
Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia |
instacron_str |
IBEPEGE |
institution |
IBEPEGE |
reponame_str |
Arquivos de gastroenterologia (Online) |
collection |
Arquivos de gastroenterologia (Online) |
repository.name.fl_str_mv |
Arquivos de gastroenterologia (Online) - Instituto Brasileiro de Estudos e Pesquisas de Gastroenterologia |
repository.mail.fl_str_mv |
||secretariaarqgastr@hospitaligesp.com.br |
_version_ |
1754193348042686464 |