The users centered design of a new digital fluorometer
Autor(a) principal: | |
---|---|
Data de Publicação: | 2009 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo de conferência |
Idioma: | por |
Título da fonte: | Repositório Institucional do IEN |
Texto Completo: | http://carpedien.ien.gov.br:8080/handle/ien/2436 |
Resumo: | The fluorometer is the equipment used in chemical analysis laboratories, research institutes and nuclear fuel cycle companies. This equipment measures an unknown amount of uranium in ores, rivers, etc. The fluorometer functioning is based on the uranium fluorescence when submitted to the ultraviolet radiation incidence. The fluorescence is measured by an electronic optic system with optics filters, photomultiplier tube, and a current amplifier. The user centered design involvers the user in the product development in all phases of the design process. Users are not simply consulted at the beginning of the design process and evaluated the system at the end; they are treated as partners throughout the design process. The user centered design emphasizes the needs and abilities of the users and improves the usability of the equipment. The activity centered design emphasizes the development of the equipment with a deep understanding of the users activities and of the current work practices of the users. The aim of this paper is to present a methodological framework that contributes to the design and evaluation of a new digital fluorometer towards an approach related to the users and their activities. This methodological framework includes users-based testing, interviews, questionnaires, human factors standards and guidelines, the users activity analysis and users satisfaction questionnaire. |
id |
IEN_13e6adfd51a455c7fc53a8fc834be99e |
---|---|
oai_identifier_str |
oai:carpedien.ien.gov.br:ien/2436 |
network_acronym_str |
IEN |
network_name_str |
Repositório Institucional do IEN |
spelling |
Farias, Marcos SantanaSantos, Isaac José Antonio Luquetti dosGrecco, Claudio Henrique dos SantosPedrosa, Paulo SergioColthurst, Carlos Mc DonaldSzabó, Andre PedroInstituto de Engenharia Nuclear2018-06-08T17:56:44Z2018-06-08T17:56:44Z2009-09http://carpedien.ien.gov.br:8080/handle/ien/2436Submitted by Almir Azevedo (barbio1313@gmail.com) on 2018-06-08T17:56:44Z No. of bitstreams: 1 THE USERS CENTERED DESIGN OF A NEW DIGITAL FLUOROMETER.pdf: 137112 bytes, checksum: 5a51578beb16f9251ae0eb135efbaf10 (MD5)Made available in DSpace on 2018-06-08T17:56:44Z (GMT). No. of bitstreams: 1 THE USERS CENTERED DESIGN OF A NEW DIGITAL FLUOROMETER.pdf: 137112 bytes, checksum: 5a51578beb16f9251ae0eb135efbaf10 (MD5) Previous issue date: 2009-09The fluorometer is the equipment used in chemical analysis laboratories, research institutes and nuclear fuel cycle companies. This equipment measures an unknown amount of uranium in ores, rivers, etc. The fluorometer functioning is based on the uranium fluorescence when submitted to the ultraviolet radiation incidence. The fluorescence is measured by an electronic optic system with optics filters, photomultiplier tube, and a current amplifier. The user centered design involvers the user in the product development in all phases of the design process. Users are not simply consulted at the beginning of the design process and evaluated the system at the end; they are treated as partners throughout the design process. The user centered design emphasizes the needs and abilities of the users and improves the usability of the equipment. The activity centered design emphasizes the development of the equipment with a deep understanding of the users activities and of the current work practices of the users. The aim of this paper is to present a methodological framework that contributes to the design and evaluation of a new digital fluorometer towards an approach related to the users and their activities. This methodological framework includes users-based testing, interviews, questionnaires, human factors standards and guidelines, the users activity analysis and users satisfaction questionnaire.porInstituto de Engenharia NuclearIENBrasilFluorômetro digitalThe users centered design of a new digital fluorometerinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObjectIV INACinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional do IENinstname:Instituto de Engenharia Nuclearinstacron:IENLICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/2436/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52ORIGINALTHE USERS CENTERED DESIGN OF A NEW DIGITAL FLUOROMETER.pdfTHE USERS CENTERED DESIGN OF A NEW DIGITAL FLUOROMETER.pdfapplication/pdf137112http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/2436/1/THE+USERS+CENTERED+DESIGN+OF+A+NEW+DIGITAL+FLUOROMETER.pdf5a51578beb16f9251ae0eb135efbaf10MD51ien/2436oai:carpedien.ien.gov.br:ien/24362018-06-08 14:56:44.869Dspace IENlsales@ien.gov.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 |
dc.title.pt_BR.fl_str_mv |
The users centered design of a new digital fluorometer |
title |
The users centered design of a new digital fluorometer |
spellingShingle |
The users centered design of a new digital fluorometer Farias, Marcos Santana Fluorômetro digital |
title_short |
The users centered design of a new digital fluorometer |
title_full |
The users centered design of a new digital fluorometer |
title_fullStr |
The users centered design of a new digital fluorometer |
title_full_unstemmed |
The users centered design of a new digital fluorometer |
title_sort |
The users centered design of a new digital fluorometer |
author |
Farias, Marcos Santana |
author_facet |
Farias, Marcos Santana Santos, Isaac José Antonio Luquetti dos Grecco, Claudio Henrique dos Santos Pedrosa, Paulo Sergio Colthurst, Carlos Mc Donald Szabó, Andre Pedro Instituto de Engenharia Nuclear |
author_role |
author |
author2 |
Santos, Isaac José Antonio Luquetti dos Grecco, Claudio Henrique dos Santos Pedrosa, Paulo Sergio Colthurst, Carlos Mc Donald Szabó, Andre Pedro Instituto de Engenharia Nuclear |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Farias, Marcos Santana Santos, Isaac José Antonio Luquetti dos Grecco, Claudio Henrique dos Santos Pedrosa, Paulo Sergio Colthurst, Carlos Mc Donald Szabó, Andre Pedro Instituto de Engenharia Nuclear |
dc.subject.por.fl_str_mv |
Fluorômetro digital |
topic |
Fluorômetro digital |
dc.description.abstract.por.fl_txt_mv |
The fluorometer is the equipment used in chemical analysis laboratories, research institutes and nuclear fuel cycle companies. This equipment measures an unknown amount of uranium in ores, rivers, etc. The fluorometer functioning is based on the uranium fluorescence when submitted to the ultraviolet radiation incidence. The fluorescence is measured by an electronic optic system with optics filters, photomultiplier tube, and a current amplifier. The user centered design involvers the user in the product development in all phases of the design process. Users are not simply consulted at the beginning of the design process and evaluated the system at the end; they are treated as partners throughout the design process. The user centered design emphasizes the needs and abilities of the users and improves the usability of the equipment. The activity centered design emphasizes the development of the equipment with a deep understanding of the users activities and of the current work practices of the users. The aim of this paper is to present a methodological framework that contributes to the design and evaluation of a new digital fluorometer towards an approach related to the users and their activities. This methodological framework includes users-based testing, interviews, questionnaires, human factors standards and guidelines, the users activity analysis and users satisfaction questionnaire. |
description |
The fluorometer is the equipment used in chemical analysis laboratories, research institutes and nuclear fuel cycle companies. This equipment measures an unknown amount of uranium in ores, rivers, etc. The fluorometer functioning is based on the uranium fluorescence when submitted to the ultraviolet radiation incidence. The fluorescence is measured by an electronic optic system with optics filters, photomultiplier tube, and a current amplifier. The user centered design involvers the user in the product development in all phases of the design process. Users are not simply consulted at the beginning of the design process and evaluated the system at the end; they are treated as partners throughout the design process. The user centered design emphasizes the needs and abilities of the users and improves the usability of the equipment. The activity centered design emphasizes the development of the equipment with a deep understanding of the users activities and of the current work practices of the users. The aim of this paper is to present a methodological framework that contributes to the design and evaluation of a new digital fluorometer towards an approach related to the users and their activities. This methodological framework includes users-based testing, interviews, questionnaires, human factors standards and guidelines, the users activity analysis and users satisfaction questionnaire. |
publishDate |
2009 |
dc.date.issued.fl_str_mv |
2009-09 |
dc.date.accessioned.fl_str_mv |
2018-06-08T17:56:44Z |
dc.date.available.fl_str_mv |
2018-06-08T17:56:44Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
status_str |
publishedVersion |
format |
conferenceObject |
dc.identifier.uri.fl_str_mv |
http://carpedien.ien.gov.br:8080/handle/ien/2436 |
url |
http://carpedien.ien.gov.br:8080/handle/ien/2436 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Instituto de Engenharia Nuclear |
dc.publisher.initials.fl_str_mv |
IEN |
dc.publisher.country.fl_str_mv |
Brasil |
publisher.none.fl_str_mv |
Instituto de Engenharia Nuclear |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional do IEN instname:Instituto de Engenharia Nuclear instacron:IEN |
reponame_str |
Repositório Institucional do IEN |
collection |
Repositório Institucional do IEN |
instname_str |
Instituto de Engenharia Nuclear |
instacron_str |
IEN |
institution |
IEN |
bitstream.url.fl_str_mv |
http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/2436/2/license.txt http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/2436/1/THE+USERS+CENTERED+DESIGN+OF+A+NEW+DIGITAL+FLUOROMETER.pdf |
bitstream.checksum.fl_str_mv |
8a4605be74aa9ea9d79846c1fba20a33 5a51578beb16f9251ae0eb135efbaf10 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Dspace IEN |
repository.mail.fl_str_mv |
lsales@ien.gov.br |
_version_ |
1656026994042732544 |