Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility test
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Einstein (São Paulo) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082016000200018 |
Resumo: | ABSTRACT Objective To compare sterility and microbial (bacteria and fungi) load in the outer part of hyperbaric bupivacaine (Neocaína®) in ampoule and bupivacaine in vial, in conventional and sterile pack formulations. Methods The sterile packs were divided into two groups: G1 (n=16) with ampoules and G2 (n=16) with vials. Conventional formulations were divided into two groups, being G3 (n=16) with ampoules and G4 (n=16) with vials. The ampoules and vials were opened and had their content drawn. The empty bottles were then placed in sterile plastic bags and sent for analysis of microbial load (bacteria and fungi) and sterility testing. Data were analyzed using the χ2 test with Yates correction, and 95% confidence interval. Results G1 and G2 showed no bacterial growth when compared to conventional groups (p<0.001). The most common agent in conventional microbiological samples was Staphylococcus aureus. There was no fungal growth in both groups. Conclusion The use of (sterile pack) reduces the microbial load of bottles, and would decrease the chance of exposure to potential contamination of the anesthetic solution. |
id |
IIEPAE-1_af83f294e521708eef05a2ee7c13f16e |
---|---|
oai_identifier_str |
oai:scielo:S1679-45082016000200018 |
network_acronym_str |
IIEPAE-1 |
network_name_str |
Einstein (São Paulo) |
repository_id_str |
|
spelling |
Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility testInfection controlAnesthesiaContaminationAnesthesia, conductionABSTRACT Objective To compare sterility and microbial (bacteria and fungi) load in the outer part of hyperbaric bupivacaine (Neocaína®) in ampoule and bupivacaine in vial, in conventional and sterile pack formulations. Methods The sterile packs were divided into two groups: G1 (n=16) with ampoules and G2 (n=16) with vials. Conventional formulations were divided into two groups, being G3 (n=16) with ampoules and G4 (n=16) with vials. The ampoules and vials were opened and had their content drawn. The empty bottles were then placed in sterile plastic bags and sent for analysis of microbial load (bacteria and fungi) and sterility testing. Data were analyzed using the χ2 test with Yates correction, and 95% confidence interval. Results G1 and G2 showed no bacterial growth when compared to conventional groups (p<0.001). The most common agent in conventional microbiological samples was Staphylococcus aureus. There was no fungal growth in both groups. Conclusion The use of (sterile pack) reduces the microbial load of bottles, and would decrease the chance of exposure to potential contamination of the anesthetic solution.Instituto Israelita de Ensino e Pesquisa Albert Einstein2016-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082016000200018einstein (São Paulo) v.14 n.2 2016reponame:Einstein (São Paulo)instname:Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)instacron:IIEPAE10.1590/S1679-45082016AO3484info:eu-repo/semantics/openAccessFreitas,Raphael Ribeiro de AquinoTardelli,Maria Angelaeng2016-07-20T00:00:00Zoai:scielo:S1679-45082016000200018Revistahttps://journal.einstein.br/pt-br/ONGhttps://old.scielo.br/oai/scielo-oai.php||revista@einstein.br2317-63851679-4508opendoar:2016-07-20T00:00Einstein (São Paulo) - Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)false |
dc.title.none.fl_str_mv |
Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility test |
title |
Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility test |
spellingShingle |
Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility test Freitas,Raphael Ribeiro de Aquino Infection control Anesthesia Contamination Anesthesia, conduction |
title_short |
Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility test |
title_full |
Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility test |
title_fullStr |
Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility test |
title_full_unstemmed |
Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility test |
title_sort |
Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility test |
author |
Freitas,Raphael Ribeiro de Aquino |
author_facet |
Freitas,Raphael Ribeiro de Aquino Tardelli,Maria Angela |
author_role |
author |
author2 |
Tardelli,Maria Angela |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Freitas,Raphael Ribeiro de Aquino Tardelli,Maria Angela |
dc.subject.por.fl_str_mv |
Infection control Anesthesia Contamination Anesthesia, conduction |
topic |
Infection control Anesthesia Contamination Anesthesia, conduction |
description |
ABSTRACT Objective To compare sterility and microbial (bacteria and fungi) load in the outer part of hyperbaric bupivacaine (Neocaína®) in ampoule and bupivacaine in vial, in conventional and sterile pack formulations. Methods The sterile packs were divided into two groups: G1 (n=16) with ampoules and G2 (n=16) with vials. Conventional formulations were divided into two groups, being G3 (n=16) with ampoules and G4 (n=16) with vials. The ampoules and vials were opened and had their content drawn. The empty bottles were then placed in sterile plastic bags and sent for analysis of microbial load (bacteria and fungi) and sterility testing. Data were analyzed using the χ2 test with Yates correction, and 95% confidence interval. Results G1 and G2 showed no bacterial growth when compared to conventional groups (p<0.001). The most common agent in conventional microbiological samples was Staphylococcus aureus. There was no fungal growth in both groups. Conclusion The use of (sterile pack) reduces the microbial load of bottles, and would decrease the chance of exposure to potential contamination of the anesthetic solution. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082016000200018 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082016000200018 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1679-45082016AO3484 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Instituto Israelita de Ensino e Pesquisa Albert Einstein |
publisher.none.fl_str_mv |
Instituto Israelita de Ensino e Pesquisa Albert Einstein |
dc.source.none.fl_str_mv |
einstein (São Paulo) v.14 n.2 2016 reponame:Einstein (São Paulo) instname:Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE) instacron:IIEPAE |
instname_str |
Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE) |
instacron_str |
IIEPAE |
institution |
IIEPAE |
reponame_str |
Einstein (São Paulo) |
collection |
Einstein (São Paulo) |
repository.name.fl_str_mv |
Einstein (São Paulo) - Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE) |
repository.mail.fl_str_mv |
||revista@einstein.br |
_version_ |
1752129908724727808 |