Microimmunodiffusion test for the serodiagnosis of paracoccidioidomycosis
Autor(a) principal: | |
---|---|
Data de Publicação: | 1989 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista do Instituto de Medicina Tropical de São Paulo |
Texto Completo: | https://www.revistas.usp.br/rimtsp/article/view/28633 |
Resumo: | We used the micro- and macroimmunodiffusion test for the qualitative and quantitative measurement of anti - P. brasiliensis antibodies in serum of patients with paracoccidioidomycosis. All 103 paracoccidioidomycosis sera (100%) were positive in the micro test versus 87% positivity index in the macrotest. All 83 control sera from patients with other diseases were negative in both tests. Titers of the positive sera tended to be higher in the microtest, which revealed sharper and easier to read precipiting bands. Microimmunodiffusion is simple to be performed, requires a minimum amount of reagents and allows the simultaneous testing of 102 sera. It may replace the macrotest specially in laboratories dealing with great serologic routine. |
id |
IMT-1_2dea5eba4fdf93839a71ab2ba23dce46 |
---|---|
oai_identifier_str |
oai:revistas.usp.br:article/28633 |
network_acronym_str |
IMT-1 |
network_name_str |
Revista do Instituto de Medicina Tropical de São Paulo |
repository_id_str |
|
spelling |
Microimmunodiffusion test for the serodiagnosis of paracoccidioidomycosis Reação de microimunodifusão em gel de ágar no diagnóstico sorológico da paracoccidioidomicose ParacoccidioidomicoseMicroimunodifusão We used the micro- and macroimmunodiffusion test for the qualitative and quantitative measurement of anti - P. brasiliensis antibodies in serum of patients with paracoccidioidomycosis. All 103 paracoccidioidomycosis sera (100%) were positive in the micro test versus 87% positivity index in the macrotest. All 83 control sera from patients with other diseases were negative in both tests. Titers of the positive sera tended to be higher in the microtest, which revealed sharper and easier to read precipiting bands. Microimmunodiffusion is simple to be performed, requires a minimum amount of reagents and allows the simultaneous testing of 102 sera. It may replace the macrotest specially in laboratories dealing with great serologic routine. Utilizou-se técnica de microimunodifusão dupla em gel de ágar para a medida quali e quantitativa de anticorpos circulantes anti - P. brasiliensis, comparando-se os resultados com o macrométodo. Todos os 103 soros de pacientes portadores de paracoccidioidomicose foram positivos no micrométodo contra 87% de positividade no macrométodo. Os 83 soros de pacientes sem paracoccidioidomicose foram negativos em ambas as reações. Os títulos dos soros positivos tenderam a ser mais elevados no micrométodo, que forneceu bandas de precipitação mais nítidas e fáceis de serem lidas. O micrométodo é de realização simples, utiliza pequena quantidade de material e possibilita o teste simultâneo de 102 soros. Acreditamos que ele poderá substituir o macrométodo, especialmente em laboratórios de grande rotina sorológica. Universidade de São Paulo. Instituto de Medicina Tropical de São Paulo1989-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/rimtsp/article/view/28633Revista do Instituto de Medicina Tropical de São Paulo; Vol. 31 No. 1 (1989); 40-43 Revista do Instituto de Medicina Tropical de São Paulo; Vol. 31 Núm. 1 (1989); 40-43 Revista do Instituto de Medicina Tropical de São Paulo; v. 31 n. 1 (1989); 40-43 1678-99460036-4665reponame:Revista do Instituto de Medicina Tropical de São Pauloinstname:Instituto de Medicina Tropical (IMT)instacron:IMTenghttps://www.revistas.usp.br/rimtsp/article/view/28633/30486Copyright (c) 2018 Revista do Instituto de Medicina Tropical de São Pauloinfo:eu-repo/semantics/openAccessSilva, Maria Isabel Correa daChamma, Luiz GastãoFranco, Marcello2012-07-02T01:08:13Zoai:revistas.usp.br:article/28633Revistahttp://www.revistas.usp.br/rimtsp/indexPUBhttps://www.revistas.usp.br/rimtsp/oai||revimtsp@usp.br1678-99460036-4665opendoar:2022-12-13T16:50:22.644091Revista do Instituto de Medicina Tropical de São Paulo - Instituto de Medicina Tropical (IMT)true |
dc.title.none.fl_str_mv |
Microimmunodiffusion test for the serodiagnosis of paracoccidioidomycosis Reação de microimunodifusão em gel de ágar no diagnóstico sorológico da paracoccidioidomicose |
title |
Microimmunodiffusion test for the serodiagnosis of paracoccidioidomycosis |
spellingShingle |
Microimmunodiffusion test for the serodiagnosis of paracoccidioidomycosis Silva, Maria Isabel Correa da Paracoccidioidomicose Microimunodifusão |
title_short |
Microimmunodiffusion test for the serodiagnosis of paracoccidioidomycosis |
title_full |
Microimmunodiffusion test for the serodiagnosis of paracoccidioidomycosis |
title_fullStr |
Microimmunodiffusion test for the serodiagnosis of paracoccidioidomycosis |
title_full_unstemmed |
Microimmunodiffusion test for the serodiagnosis of paracoccidioidomycosis |
title_sort |
Microimmunodiffusion test for the serodiagnosis of paracoccidioidomycosis |
author |
Silva, Maria Isabel Correa da |
author_facet |
Silva, Maria Isabel Correa da Chamma, Luiz Gastão Franco, Marcello |
author_role |
author |
author2 |
Chamma, Luiz Gastão Franco, Marcello |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Silva, Maria Isabel Correa da Chamma, Luiz Gastão Franco, Marcello |
dc.subject.por.fl_str_mv |
Paracoccidioidomicose Microimunodifusão |
topic |
Paracoccidioidomicose Microimunodifusão |
description |
We used the micro- and macroimmunodiffusion test for the qualitative and quantitative measurement of anti - P. brasiliensis antibodies in serum of patients with paracoccidioidomycosis. All 103 paracoccidioidomycosis sera (100%) were positive in the micro test versus 87% positivity index in the macrotest. All 83 control sera from patients with other diseases were negative in both tests. Titers of the positive sera tended to be higher in the microtest, which revealed sharper and easier to read precipiting bands. Microimmunodiffusion is simple to be performed, requires a minimum amount of reagents and allows the simultaneous testing of 102 sera. It may replace the macrotest specially in laboratories dealing with great serologic routine. |
publishDate |
1989 |
dc.date.none.fl_str_mv |
1989-02-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://www.revistas.usp.br/rimtsp/article/view/28633 |
url |
https://www.revistas.usp.br/rimtsp/article/view/28633 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://www.revistas.usp.br/rimtsp/article/view/28633/30486 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2018 Revista do Instituto de Medicina Tropical de São Paulo info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2018 Revista do Instituto de Medicina Tropical de São Paulo |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade de São Paulo. Instituto de Medicina Tropical de São Paulo |
publisher.none.fl_str_mv |
Universidade de São Paulo. Instituto de Medicina Tropical de São Paulo |
dc.source.none.fl_str_mv |
Revista do Instituto de Medicina Tropical de São Paulo; Vol. 31 No. 1 (1989); 40-43 Revista do Instituto de Medicina Tropical de São Paulo; Vol. 31 Núm. 1 (1989); 40-43 Revista do Instituto de Medicina Tropical de São Paulo; v. 31 n. 1 (1989); 40-43 1678-9946 0036-4665 reponame:Revista do Instituto de Medicina Tropical de São Paulo instname:Instituto de Medicina Tropical (IMT) instacron:IMT |
instname_str |
Instituto de Medicina Tropical (IMT) |
instacron_str |
IMT |
institution |
IMT |
reponame_str |
Revista do Instituto de Medicina Tropical de São Paulo |
collection |
Revista do Instituto de Medicina Tropical de São Paulo |
repository.name.fl_str_mv |
Revista do Instituto de Medicina Tropical de São Paulo - Instituto de Medicina Tropical (IMT) |
repository.mail.fl_str_mv |
||revimtsp@usp.br |
_version_ |
1798951637850521600 |