Peroxidase antibody test for mucocutaneous leishmaniasis serology performance indexes and comparison with a fluorescent antibody test: Comparação com o desempenho da reação de imunofluorescência

Detalhes bibliográficos
Autor(a) principal: Celeste, Beatriz J.
Data de Publicação: 1988
Outros Autores: Guimarães, M. Carolina S., Corrales L., Edelma Maria
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista do Instituto de Medicina Tropical de São Paulo
Texto Completo: https://www.revistas.usp.br/rimtsp/article/view/28619
Resumo: Performance indexes of the peroxidase antibody test were compared to that of the fluorescent antibody test. The peroxidase antibody test had a statistically higher sensitivity and negative predictive value and a higher efficiency than the fluorescent antibody test but its specificity and positive predictive value were within the 95% confidence limits for the values found for the fluorescent antibody test. Such differences did not change when Chagas' disease and visceral leishmaniasis sera were included in index calculations. Statistical analysis showed that the two tests have a substantial degree of agreement but the immunofluorescent test had a specificity index and a positive predictive value equal to 100.0% when Chagas' disease and visceral leishmaniasis sera were not included in the calculations of the performance index; in this instance, a positive test result equals a disclosure of the disease attribute due to the inexistence of false positive results. The enzyme/ protein ratio of the peroxidase conjugate, resulting in heavy or light-labeled conjugates may pose technical problems to its use in serology tests.
id IMT-1_6917fc26a8648457a4d459a9fc2070a9
oai_identifier_str oai:revistas.usp.br:article/28619
network_acronym_str IMT-1
network_name_str Revista do Instituto de Medicina Tropical de São Paulo
repository_id_str
spelling Peroxidase antibody test for mucocutaneous leishmaniasis serology performance indexes and comparison with a fluorescent antibody test: Comparação com o desempenho da reação de imunofluorescência Teste de imunoperoxidase para a sorologia da leishmaniose mueocutânea Mucocutaneous leishmaniasis serologyPerformance indexPeroxidase antibody testFluorescent antibody test Performance indexes of the peroxidase antibody test were compared to that of the fluorescent antibody test. The peroxidase antibody test had a statistically higher sensitivity and negative predictive value and a higher efficiency than the fluorescent antibody test but its specificity and positive predictive value were within the 95% confidence limits for the values found for the fluorescent antibody test. Such differences did not change when Chagas' disease and visceral leishmaniasis sera were included in index calculations. Statistical analysis showed that the two tests have a substantial degree of agreement but the immunofluorescent test had a specificity index and a positive predictive value equal to 100.0% when Chagas' disease and visceral leishmaniasis sera were not included in the calculations of the performance index; in this instance, a positive test result equals a disclosure of the disease attribute due to the inexistence of false positive results. The enzyme/ protein ratio of the peroxidase conjugate, resulting in heavy or light-labeled conjugates may pose technical problems to its use in serology tests. Os parâmetros sorológicos do teste de imunoperoxidase foram comparados aos do teste de imunofluorescência. O teste de imunoperoxidase mostrou ter sensibilidade e valor de predição negativo estatisticamente mais alto que aqueles do teste de imunofluorescência porém, os limites de confiança 95% da especificidade e do valor de predição positivo estavam contidos naqueles encontrados para o teste de imunofluorescência. Tais diferenças se mantiveram quando os cálculos dos índices foram feitos com e sem a inclusão de soros de doença de Chagas ou leishmaniose visceral. A análise estatística mostrou que os dois testes tinham um grau substancial de concordância mas o teste de imunofluorescência tinha um índice de especificidade e o vaior de predição positivo igual a 100,0% quando os soros de Chagas e leishmaniose visceral foram excluídos. Neste caso. o teste positivo se torna o teste diagnóstico da doença em face da não existência de falso-positivos. O conjugado de peroxidase poderá se constituir em fonte de problemas técnicos na sorologia se a relação enzima proteína se afastar das quantidades ótimas de marcação. Universidade de São Paulo. Instituto de Medicina Tropical de São Paulo1988-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://www.revistas.usp.br/rimtsp/article/view/28619Revista do Instituto de Medicina Tropical de São Paulo; Vol. 30 No. 6 (1988); 411-414 Revista do Instituto de Medicina Tropical de São Paulo; Vol. 30 Núm. 6 (1988); 411-414 Revista do Instituto de Medicina Tropical de São Paulo; v. 30 n. 6 (1988); 411-414 1678-99460036-4665reponame:Revista do Instituto de Medicina Tropical de São Pauloinstname:Instituto de Medicina Tropical (IMT)instacron:IMTenghttps://www.revistas.usp.br/rimtsp/article/view/28619/30472Copyright (c) 2018 Revista do Instituto de Medicina Tropical de São Pauloinfo:eu-repo/semantics/openAccessCeleste, Beatriz J.Guimarães, M. Carolina S.Corrales L., Edelma Maria2012-07-02T01:07:12Zoai:revistas.usp.br:article/28619Revistahttp://www.revistas.usp.br/rimtsp/indexPUBhttps://www.revistas.usp.br/rimtsp/oai||revimtsp@usp.br1678-99460036-4665opendoar:2022-12-13T16:50:21.757610Revista do Instituto de Medicina Tropical de São Paulo - Instituto de Medicina Tropical (IMT)true
dc.title.none.fl_str_mv Peroxidase antibody test for mucocutaneous leishmaniasis serology performance indexes and comparison with a fluorescent antibody test: Comparação com o desempenho da reação de imunofluorescência
Teste de imunoperoxidase para a sorologia da leishmaniose mueocutânea
title Peroxidase antibody test for mucocutaneous leishmaniasis serology performance indexes and comparison with a fluorescent antibody test: Comparação com o desempenho da reação de imunofluorescência
spellingShingle Peroxidase antibody test for mucocutaneous leishmaniasis serology performance indexes and comparison with a fluorescent antibody test: Comparação com o desempenho da reação de imunofluorescência
Celeste, Beatriz J.
Mucocutaneous leishmaniasis serology
Performance index
Peroxidase antibody test
Fluorescent antibody test
title_short Peroxidase antibody test for mucocutaneous leishmaniasis serology performance indexes and comparison with a fluorescent antibody test: Comparação com o desempenho da reação de imunofluorescência
title_full Peroxidase antibody test for mucocutaneous leishmaniasis serology performance indexes and comparison with a fluorescent antibody test: Comparação com o desempenho da reação de imunofluorescência
title_fullStr Peroxidase antibody test for mucocutaneous leishmaniasis serology performance indexes and comparison with a fluorescent antibody test: Comparação com o desempenho da reação de imunofluorescência
title_full_unstemmed Peroxidase antibody test for mucocutaneous leishmaniasis serology performance indexes and comparison with a fluorescent antibody test: Comparação com o desempenho da reação de imunofluorescência
title_sort Peroxidase antibody test for mucocutaneous leishmaniasis serology performance indexes and comparison with a fluorescent antibody test: Comparação com o desempenho da reação de imunofluorescência
author Celeste, Beatriz J.
author_facet Celeste, Beatriz J.
Guimarães, M. Carolina S.
Corrales L., Edelma Maria
author_role author
author2 Guimarães, M. Carolina S.
Corrales L., Edelma Maria
author2_role author
author
dc.contributor.author.fl_str_mv Celeste, Beatriz J.
Guimarães, M. Carolina S.
Corrales L., Edelma Maria
dc.subject.por.fl_str_mv Mucocutaneous leishmaniasis serology
Performance index
Peroxidase antibody test
Fluorescent antibody test
topic Mucocutaneous leishmaniasis serology
Performance index
Peroxidase antibody test
Fluorescent antibody test
description Performance indexes of the peroxidase antibody test were compared to that of the fluorescent antibody test. The peroxidase antibody test had a statistically higher sensitivity and negative predictive value and a higher efficiency than the fluorescent antibody test but its specificity and positive predictive value were within the 95% confidence limits for the values found for the fluorescent antibody test. Such differences did not change when Chagas' disease and visceral leishmaniasis sera were included in index calculations. Statistical analysis showed that the two tests have a substantial degree of agreement but the immunofluorescent test had a specificity index and a positive predictive value equal to 100.0% when Chagas' disease and visceral leishmaniasis sera were not included in the calculations of the performance index; in this instance, a positive test result equals a disclosure of the disease attribute due to the inexistence of false positive results. The enzyme/ protein ratio of the peroxidase conjugate, resulting in heavy or light-labeled conjugates may pose technical problems to its use in serology tests.
publishDate 1988
dc.date.none.fl_str_mv 1988-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://www.revistas.usp.br/rimtsp/article/view/28619
url https://www.revistas.usp.br/rimtsp/article/view/28619
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://www.revistas.usp.br/rimtsp/article/view/28619/30472
dc.rights.driver.fl_str_mv Copyright (c) 2018 Revista do Instituto de Medicina Tropical de São Paulo
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2018 Revista do Instituto de Medicina Tropical de São Paulo
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de São Paulo. Instituto de Medicina Tropical de São Paulo
publisher.none.fl_str_mv Universidade de São Paulo. Instituto de Medicina Tropical de São Paulo
dc.source.none.fl_str_mv Revista do Instituto de Medicina Tropical de São Paulo; Vol. 30 No. 6 (1988); 411-414
Revista do Instituto de Medicina Tropical de São Paulo; Vol. 30 Núm. 6 (1988); 411-414
Revista do Instituto de Medicina Tropical de São Paulo; v. 30 n. 6 (1988); 411-414
1678-9946
0036-4665
reponame:Revista do Instituto de Medicina Tropical de São Paulo
instname:Instituto de Medicina Tropical (IMT)
instacron:IMT
instname_str Instituto de Medicina Tropical (IMT)
instacron_str IMT
institution IMT
reponame_str Revista do Instituto de Medicina Tropical de São Paulo
collection Revista do Instituto de Medicina Tropical de São Paulo
repository.name.fl_str_mv Revista do Instituto de Medicina Tropical de São Paulo - Instituto de Medicina Tropical (IMT)
repository.mail.fl_str_mv ||revimtsp@usp.br
_version_ 1798951637827452928