On line pre-concentration for simultaneous determination of low molecular weight organic acids and inorganic anions in Amazonian river water samples employing ion chromatography with conductivity detection

Detalhes bibliográficos
Autor(a) principal: Tumang,Cristiane Azevedo
Data de Publicação: 2009
Outros Autores: Krusche,Alex Vladimir, Victoria,Reynaldo Luis, Richey,Jeffrey Edward
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Acta Amazonica
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0044-59672009000200019
Resumo: An ion chromatography procedure, employing an IonPac AC15 concentrator column was used to investigate on line preconcentration for the simultaneous determination of inorganic anions and organic acids in river water. Twelve organic acids and nine inorganic anions were separated without any interference from other compounds and carry-over problems between samples. The injection loop was replaced by a Dionex AC15 concentrator column. The proposed procedure employed an auto-sampler that injected 1.5 ml of sample into a KOH mobile phase, generated by an Eluent Generator, at 1.5 mL min-1, which carried the sample to the chromatographic columns (one guard column, model AG-15, and one analytical column, model AS15, with 250 x 4mm i.d.). The gradient elution concentrations consisted of a 10.0 mmol l-1 KOH solution from 0 to 6.5 min, gradually increased to 45.0 mmol l-1 KOH at 21 min., and immediatelly returned and maintained at the initial concentrations until 24 min. of total run. The compounds were eluted and transported to an electro-conductivity detection cell that was attached to an electrochemical detector. The advantage of using concentrator column was the capability of performing routine simultaneous determinations for ions from 0.01 to 1.0 mg l-1 organic acids (acetate, propionic acid, formic acid, butyric acid, glycolic acid, pyruvate, tartaric acid, phthalic acid, methanesulfonic acid, valeric acid, maleic acid, oxalic acid, chlorate and citric acid) and 0.01 to 5.0 mg l-1 inorganic anions (fluoride, chloride, nitrite, nitrate, bromide, sulfate and phosphate), without extensive sample pretreatment and with an analysis time of only 24 minutes.
id INPA-3_b589dd6db4e1f28b85e98fb8432c2867
oai_identifier_str oai:scielo:S0044-59672009000200019
network_acronym_str INPA-3
network_name_str Acta Amazonica
repository_id_str
spelling On line pre-concentration for simultaneous determination of low molecular weight organic acids and inorganic anions in Amazonian river water samples employing ion chromatography with conductivity detectionOn-line pre-concentrationinorganic anionsorganic anionsion chromatographyriver watersAn ion chromatography procedure, employing an IonPac AC15 concentrator column was used to investigate on line preconcentration for the simultaneous determination of inorganic anions and organic acids in river water. Twelve organic acids and nine inorganic anions were separated without any interference from other compounds and carry-over problems between samples. The injection loop was replaced by a Dionex AC15 concentrator column. The proposed procedure employed an auto-sampler that injected 1.5 ml of sample into a KOH mobile phase, generated by an Eluent Generator, at 1.5 mL min-1, which carried the sample to the chromatographic columns (one guard column, model AG-15, and one analytical column, model AS15, with 250 x 4mm i.d.). The gradient elution concentrations consisted of a 10.0 mmol l-1 KOH solution from 0 to 6.5 min, gradually increased to 45.0 mmol l-1 KOH at 21 min., and immediatelly returned and maintained at the initial concentrations until 24 min. of total run. The compounds were eluted and transported to an electro-conductivity detection cell that was attached to an electrochemical detector. The advantage of using concentrator column was the capability of performing routine simultaneous determinations for ions from 0.01 to 1.0 mg l-1 organic acids (acetate, propionic acid, formic acid, butyric acid, glycolic acid, pyruvate, tartaric acid, phthalic acid, methanesulfonic acid, valeric acid, maleic acid, oxalic acid, chlorate and citric acid) and 0.01 to 5.0 mg l-1 inorganic anions (fluoride, chloride, nitrite, nitrate, bromide, sulfate and phosphate), without extensive sample pretreatment and with an analysis time of only 24 minutes.Instituto Nacional de Pesquisas da Amazônia2009-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0044-59672009000200019Acta Amazonica v.39 n.2 2009reponame:Acta Amazonicainstname:Instituto Nacional de Pesquisas da Amazônia (INPA)instacron:INPA10.1590/S0044-59672009000200019info:eu-repo/semantics/openAccessTumang,Cristiane AzevedoKrusche,Alex VladimirVictoria,Reynaldo LuisRichey,Jeffrey Edwardeng2009-08-11T00:00:00Zoai:scielo:S0044-59672009000200019Revistahttps://acta.inpa.gov.br/PUBhttps://old.scielo.br/oai/scielo-oai.phpacta@inpa.gov.br||acta@inpa.gov.br1809-43920044-5967opendoar:2009-08-11T00:00Acta Amazonica - Instituto Nacional de Pesquisas da Amazônia (INPA)false
dc.title.none.fl_str_mv On line pre-concentration for simultaneous determination of low molecular weight organic acids and inorganic anions in Amazonian river water samples employing ion chromatography with conductivity detection
title On line pre-concentration for simultaneous determination of low molecular weight organic acids and inorganic anions in Amazonian river water samples employing ion chromatography with conductivity detection
spellingShingle On line pre-concentration for simultaneous determination of low molecular weight organic acids and inorganic anions in Amazonian river water samples employing ion chromatography with conductivity detection
Tumang,Cristiane Azevedo
On-line pre-concentration
inorganic anions
organic anions
ion chromatography
river waters
title_short On line pre-concentration for simultaneous determination of low molecular weight organic acids and inorganic anions in Amazonian river water samples employing ion chromatography with conductivity detection
title_full On line pre-concentration for simultaneous determination of low molecular weight organic acids and inorganic anions in Amazonian river water samples employing ion chromatography with conductivity detection
title_fullStr On line pre-concentration for simultaneous determination of low molecular weight organic acids and inorganic anions in Amazonian river water samples employing ion chromatography with conductivity detection
title_full_unstemmed On line pre-concentration for simultaneous determination of low molecular weight organic acids and inorganic anions in Amazonian river water samples employing ion chromatography with conductivity detection
title_sort On line pre-concentration for simultaneous determination of low molecular weight organic acids and inorganic anions in Amazonian river water samples employing ion chromatography with conductivity detection
author Tumang,Cristiane Azevedo
author_facet Tumang,Cristiane Azevedo
Krusche,Alex Vladimir
Victoria,Reynaldo Luis
Richey,Jeffrey Edward
author_role author
author2 Krusche,Alex Vladimir
Victoria,Reynaldo Luis
Richey,Jeffrey Edward
author2_role author
author
author
dc.contributor.author.fl_str_mv Tumang,Cristiane Azevedo
Krusche,Alex Vladimir
Victoria,Reynaldo Luis
Richey,Jeffrey Edward
dc.subject.por.fl_str_mv On-line pre-concentration
inorganic anions
organic anions
ion chromatography
river waters
topic On-line pre-concentration
inorganic anions
organic anions
ion chromatography
river waters
description An ion chromatography procedure, employing an IonPac AC15 concentrator column was used to investigate on line preconcentration for the simultaneous determination of inorganic anions and organic acids in river water. Twelve organic acids and nine inorganic anions were separated without any interference from other compounds and carry-over problems between samples. The injection loop was replaced by a Dionex AC15 concentrator column. The proposed procedure employed an auto-sampler that injected 1.5 ml of sample into a KOH mobile phase, generated by an Eluent Generator, at 1.5 mL min-1, which carried the sample to the chromatographic columns (one guard column, model AG-15, and one analytical column, model AS15, with 250 x 4mm i.d.). The gradient elution concentrations consisted of a 10.0 mmol l-1 KOH solution from 0 to 6.5 min, gradually increased to 45.0 mmol l-1 KOH at 21 min., and immediatelly returned and maintained at the initial concentrations until 24 min. of total run. The compounds were eluted and transported to an electro-conductivity detection cell that was attached to an electrochemical detector. The advantage of using concentrator column was the capability of performing routine simultaneous determinations for ions from 0.01 to 1.0 mg l-1 organic acids (acetate, propionic acid, formic acid, butyric acid, glycolic acid, pyruvate, tartaric acid, phthalic acid, methanesulfonic acid, valeric acid, maleic acid, oxalic acid, chlorate and citric acid) and 0.01 to 5.0 mg l-1 inorganic anions (fluoride, chloride, nitrite, nitrate, bromide, sulfate and phosphate), without extensive sample pretreatment and with an analysis time of only 24 minutes.
publishDate 2009
dc.date.none.fl_str_mv 2009-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0044-59672009000200019
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0044-59672009000200019
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0044-59672009000200019
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Instituto Nacional de Pesquisas da Amazônia
publisher.none.fl_str_mv Instituto Nacional de Pesquisas da Amazônia
dc.source.none.fl_str_mv Acta Amazonica v.39 n.2 2009
reponame:Acta Amazonica
instname:Instituto Nacional de Pesquisas da Amazônia (INPA)
instacron:INPA
instname_str Instituto Nacional de Pesquisas da Amazônia (INPA)
instacron_str INPA
institution INPA
reponame_str Acta Amazonica
collection Acta Amazonica
repository.name.fl_str_mv Acta Amazonica - Instituto Nacional de Pesquisas da Amazônia (INPA)
repository.mail.fl_str_mv acta@inpa.gov.br||acta@inpa.gov.br
_version_ 1752129838193311744