Primary aromatic amines in kitchenware: Determination by liquid chromatography-tandem mass spectrometry
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório do Instituto de Tecnologia de Alimentos |
Texto Completo: | http://repositorio.ital.sp.gov.br/jspui/handle/123456789/198 |
Resumo: | The aim of this paper is to develop and validate a methodology with potential for routine analysis that allows a fast and easy quantification of 19 primary aromatic amines (PAAs) in acid simulant (3% (w/v) acetic acid aqueous) in food contact materials (FCM). The main reason for studying these amines was the fact that some of them have a carcinogenic factor according to toxicological studies. To validate the method, the parameters linearity, limit of detection (LOD) and limit of quantification (LOQ), precision and accuracy using an UPLC-MS/MS were evaluated. This study also analyzed 36 samples of kitchenware obtained from retail markets: 16 were made of polyamide (PA), one was made of polypropylene (PP) and 19 were made of silicone. The origins of samples were Brazil, China and Turkey. Eleven samples had levels of 4,4´ -diaminodiphenylmethane higher than permitted by legislation and five samples showed values of aniline above the limit. Considering the Mood test for polyamides, there were significant differences between the samples from Brazil and China, as well as between the colors in the silicone samples. Regarding the polyamides, the Chinese samples showed higher amounts of PAAs than the Brazilian ones, being above that allowed by legislation. Three Chinese silicone samples presented values above the legislation limit. These were all from the same importer. |
id |
ITAL-2_5c401161b723dce0e5373ed78f2a77dd |
---|---|
oai_identifier_str |
oai:http://repositorio.ital.sp.gov.br:123456789/198 |
network_acronym_str |
ITAL-2 |
network_name_str |
Repositório do Instituto de Tecnologia de Alimentos |
repository_id_str |
|
spelling |
Primary aromatic amines in kitchenware: Determination by liquid chromatography-tandem mass spectrometryPrimary aromatic aminesLiquid chromatography-tandem massThe aim of this paper is to develop and validate a methodology with potential for routine analysis that allows a fast and easy quantification of 19 primary aromatic amines (PAAs) in acid simulant (3% (w/v) acetic acid aqueous) in food contact materials (FCM). The main reason for studying these amines was the fact that some of them have a carcinogenic factor according to toxicological studies. To validate the method, the parameters linearity, limit of detection (LOD) and limit of quantification (LOQ), precision and accuracy using an UPLC-MS/MS were evaluated. This study also analyzed 36 samples of kitchenware obtained from retail markets: 16 were made of polyamide (PA), one was made of polypropylene (PP) and 19 were made of silicone. The origins of samples were Brazil, China and Turkey. Eleven samples had levels of 4,4´ -diaminodiphenylmethane higher than permitted by legislation and five samples showed values of aniline above the limit. Considering the Mood test for polyamides, there were significant differences between the samples from Brazil and China, as well as between the colors in the silicone samples. Regarding the polyamides, the Chinese samples showed higher amounts of PAAs than the Brazilian ones, being above that allowed by legislation. Three Chinese silicone samples presented values above the legislation limit. These were all from the same importer.FAPESP / CNPqPerez, Mary Ângela Favaro; et. al.2021-11-18T20:15:39Z2021-11-18T20:15:39Z2019info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfJournal of Chromatography A, 1602 (2019) 217–227.http://repositorio.ital.sp.gov.br/jspui/handle/123456789/198reponame:Repositório do Instituto de Tecnologia de Alimentosinstname:Instituto de Tecnologia de Alimentos (ITAL)instacron:ITALenginfo:eu-repo/semantics/openAccess2022-05-20T16:13:35Zoai:http://repositorio.ital.sp.gov.br:123456789/198Repositório InstitucionalPUBhttp://repositorio.ital.sp.gov.br/oai/requestbjftsec@ital.sp.gov.br || bjftsec@ital.sp.gov.bropendoar:2022-05-20T16:13:35Repositório do Instituto de Tecnologia de Alimentos - Instituto de Tecnologia de Alimentos (ITAL)false |
dc.title.none.fl_str_mv |
Primary aromatic amines in kitchenware: Determination by liquid chromatography-tandem mass spectrometry |
title |
Primary aromatic amines in kitchenware: Determination by liquid chromatography-tandem mass spectrometry |
spellingShingle |
Primary aromatic amines in kitchenware: Determination by liquid chromatography-tandem mass spectrometry Perez, Mary Ângela Favaro; et. al. Primary aromatic amines Liquid chromatography-tandem mass |
title_short |
Primary aromatic amines in kitchenware: Determination by liquid chromatography-tandem mass spectrometry |
title_full |
Primary aromatic amines in kitchenware: Determination by liquid chromatography-tandem mass spectrometry |
title_fullStr |
Primary aromatic amines in kitchenware: Determination by liquid chromatography-tandem mass spectrometry |
title_full_unstemmed |
Primary aromatic amines in kitchenware: Determination by liquid chromatography-tandem mass spectrometry |
title_sort |
Primary aromatic amines in kitchenware: Determination by liquid chromatography-tandem mass spectrometry |
author |
Perez, Mary Ângela Favaro; et. al. |
author_facet |
Perez, Mary Ângela Favaro; et. al. |
author_role |
author |
dc.contributor.none.fl_str_mv |
|
dc.contributor.author.fl_str_mv |
Perez, Mary Ângela Favaro; et. al. |
dc.subject.none.fl_str_mv |
|
dc.subject.por.fl_str_mv |
Primary aromatic amines Liquid chromatography-tandem mass |
topic |
Primary aromatic amines Liquid chromatography-tandem mass |
description |
The aim of this paper is to develop and validate a methodology with potential for routine analysis that allows a fast and easy quantification of 19 primary aromatic amines (PAAs) in acid simulant (3% (w/v) acetic acid aqueous) in food contact materials (FCM). The main reason for studying these amines was the fact that some of them have a carcinogenic factor according to toxicological studies. To validate the method, the parameters linearity, limit of detection (LOD) and limit of quantification (LOQ), precision and accuracy using an UPLC-MS/MS were evaluated. This study also analyzed 36 samples of kitchenware obtained from retail markets: 16 were made of polyamide (PA), one was made of polypropylene (PP) and 19 were made of silicone. The origins of samples were Brazil, China and Turkey. Eleven samples had levels of 4,4´ -diaminodiphenylmethane higher than permitted by legislation and five samples showed values of aniline above the limit. Considering the Mood test for polyamides, there were significant differences between the samples from Brazil and China, as well as between the colors in the silicone samples. Regarding the polyamides, the Chinese samples showed higher amounts of PAAs than the Brazilian ones, being above that allowed by legislation. Three Chinese silicone samples presented values above the legislation limit. These were all from the same importer. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019 2021-11-18T20:15:39Z 2021-11-18T20:15:39Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
|
dc.identifier.uri.fl_str_mv |
Journal of Chromatography A, 1602 (2019) 217–227. http://repositorio.ital.sp.gov.br/jspui/handle/123456789/198 |
identifier_str_mv |
Journal of Chromatography A, 1602 (2019) 217–227. |
url |
http://repositorio.ital.sp.gov.br/jspui/handle/123456789/198 |
dc.language.none.fl_str_mv |
|
dc.language.iso.fl_str_mv |
eng |
language_invalid_str_mv |
|
language |
eng |
dc.rights.none.fl_str_mv |
|
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
|
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
|
publisher.none.fl_str_mv |
|
dc.source.none.fl_str_mv |
reponame:Repositório do Instituto de Tecnologia de Alimentos instname:Instituto de Tecnologia de Alimentos (ITAL) instacron:ITAL |
instname_str |
Instituto de Tecnologia de Alimentos (ITAL) |
instacron_str |
ITAL |
institution |
ITAL |
reponame_str |
Repositório do Instituto de Tecnologia de Alimentos |
collection |
Repositório do Instituto de Tecnologia de Alimentos |
repository.name.fl_str_mv |
Repositório do Instituto de Tecnologia de Alimentos - Instituto de Tecnologia de Alimentos (ITAL) |
repository.mail.fl_str_mv |
bjftsec@ital.sp.gov.br || bjftsec@ital.sp.gov.br |
_version_ |
1813095547179892736 |