Determination of primary aromatic amines from cooking utensils by capillary electrophoresis-tandem mass spectrometry
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório do Instituto de Tecnologia de Alimentos |
Texto Completo: | http://repositorio.ital.sp.gov.br/jspui/handle/123456789/440 |
Resumo: | This paper describes a fast, sensitive, environment-friendly method for the determination of 19 primary aromatic amines (PAAs) in cooking utensils by capillary zone electrophoresis coupled with tandem mass spectrometry. The best electrophoretic separation of PAAs was obtained in 0.1 mol l 1 formic acid (pH 2.4) as the background electrolyte, fused silica capillary (67 cm) with a run time below 6 min. The proposed method presented a linear calibration with correlation coefficients higher than 0.99 and reproducibility in a range of 1–25%. Limits of detection were in the range of 0.2–1.3 μg kg 1 and recoveries were in a range of 85–120% for all the PAAs. The validated method was employed to determine PAAs on 36 samples of cooking utensils using acetic simulant. The results showed that 4,4′ -diaminodiphenylmethane and aniline being the most frequently found PAAs in these samples and 28% of cooking utensils were not compliant. |
id |
ITAL-2_fcadf0721c927b2baea53e01b80b3ef8 |
---|---|
oai_identifier_str |
oai:http://repositorio.ital.sp.gov.br:123456789/440 |
network_acronym_str |
ITAL-2 |
network_name_str |
Repositório do Instituto de Tecnologia de Alimentos |
repository_id_str |
|
spelling |
Determination of primary aromatic amines from cooking utensils by capillary electrophoresis-tandem mass spectrometryPrimary aromatic aminesCooking utensilsMass spectrometryElectrosprayCapillary electrophoresisThis paper describes a fast, sensitive, environment-friendly method for the determination of 19 primary aromatic amines (PAAs) in cooking utensils by capillary zone electrophoresis coupled with tandem mass spectrometry. The best electrophoretic separation of PAAs was obtained in 0.1 mol l 1 formic acid (pH 2.4) as the background electrolyte, fused silica capillary (67 cm) with a run time below 6 min. The proposed method presented a linear calibration with correlation coefficients higher than 0.99 and reproducibility in a range of 1–25%. Limits of detection were in the range of 0.2–1.3 μg kg 1 and recoveries were in a range of 85–120% for all the PAAs. The validated method was employed to determine PAAs on 36 samples of cooking utensils using acetic simulant. The results showed that 4,4′ -diaminodiphenylmethane and aniline being the most frequently found PAAs in these samples and 28% of cooking utensils were not compliant.ElsevierPerez, Mary Angela Favaro; et al.2022-09-08T18:40:41Z2022-09-08T18:40:41Z2021info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfFood Chemistry, v. 362, 129902, 2021. https://doi.org/10.1016/j.foodchem.2021.129902.http://repositorio.ital.sp.gov.br/jspui/handle/123456789/440reponame:Repositório do Instituto de Tecnologia de Alimentosinstname:Instituto de Tecnologia de Alimentos (ITAL)instacron:ITALenginfo:eu-repo/semantics/openAccess2022-09-08T18:40:42Zoai:http://repositorio.ital.sp.gov.br:123456789/440Repositório InstitucionalPUBhttp://repositorio.ital.sp.gov.br/oai/requestbjftsec@ital.sp.gov.br || bjftsec@ital.sp.gov.bropendoar:2022-09-08T18:40:42Repositório do Instituto de Tecnologia de Alimentos - Instituto de Tecnologia de Alimentos (ITAL)false |
dc.title.none.fl_str_mv |
Determination of primary aromatic amines from cooking utensils by capillary electrophoresis-tandem mass spectrometry |
title |
Determination of primary aromatic amines from cooking utensils by capillary electrophoresis-tandem mass spectrometry |
spellingShingle |
Determination of primary aromatic amines from cooking utensils by capillary electrophoresis-tandem mass spectrometry Perez, Mary Angela Favaro; et al. Primary aromatic amines Cooking utensils Mass spectrometry Electrospray Capillary electrophoresis |
title_short |
Determination of primary aromatic amines from cooking utensils by capillary electrophoresis-tandem mass spectrometry |
title_full |
Determination of primary aromatic amines from cooking utensils by capillary electrophoresis-tandem mass spectrometry |
title_fullStr |
Determination of primary aromatic amines from cooking utensils by capillary electrophoresis-tandem mass spectrometry |
title_full_unstemmed |
Determination of primary aromatic amines from cooking utensils by capillary electrophoresis-tandem mass spectrometry |
title_sort |
Determination of primary aromatic amines from cooking utensils by capillary electrophoresis-tandem mass spectrometry |
author |
Perez, Mary Angela Favaro; et al. |
author_facet |
Perez, Mary Angela Favaro; et al. |
author_role |
author |
dc.contributor.none.fl_str_mv |
|
dc.contributor.author.fl_str_mv |
Perez, Mary Angela Favaro; et al. |
dc.subject.none.fl_str_mv |
|
dc.subject.por.fl_str_mv |
Primary aromatic amines Cooking utensils Mass spectrometry Electrospray Capillary electrophoresis |
topic |
Primary aromatic amines Cooking utensils Mass spectrometry Electrospray Capillary electrophoresis |
description |
This paper describes a fast, sensitive, environment-friendly method for the determination of 19 primary aromatic amines (PAAs) in cooking utensils by capillary zone electrophoresis coupled with tandem mass spectrometry. The best electrophoretic separation of PAAs was obtained in 0.1 mol l 1 formic acid (pH 2.4) as the background electrolyte, fused silica capillary (67 cm) with a run time below 6 min. The proposed method presented a linear calibration with correlation coefficients higher than 0.99 and reproducibility in a range of 1–25%. Limits of detection were in the range of 0.2–1.3 μg kg 1 and recoveries were in a range of 85–120% for all the PAAs. The validated method was employed to determine PAAs on 36 samples of cooking utensils using acetic simulant. The results showed that 4,4′ -diaminodiphenylmethane and aniline being the most frequently found PAAs in these samples and 28% of cooking utensils were not compliant. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021 2022-09-08T18:40:41Z 2022-09-08T18:40:41Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
|
dc.identifier.uri.fl_str_mv |
Food Chemistry, v. 362, 129902, 2021. https://doi.org/10.1016/j.foodchem.2021.129902. http://repositorio.ital.sp.gov.br/jspui/handle/123456789/440 |
identifier_str_mv |
Food Chemistry, v. 362, 129902, 2021. https://doi.org/10.1016/j.foodchem.2021.129902. |
url |
http://repositorio.ital.sp.gov.br/jspui/handle/123456789/440 |
dc.language.none.fl_str_mv |
|
dc.language.iso.fl_str_mv |
eng |
language_invalid_str_mv |
|
language |
eng |
dc.rights.none.fl_str_mv |
|
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
|
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositório do Instituto de Tecnologia de Alimentos instname:Instituto de Tecnologia de Alimentos (ITAL) instacron:ITAL |
instname_str |
Instituto de Tecnologia de Alimentos (ITAL) |
instacron_str |
ITAL |
institution |
ITAL |
reponame_str |
Repositório do Instituto de Tecnologia de Alimentos |
collection |
Repositório do Instituto de Tecnologia de Alimentos |
repository.name.fl_str_mv |
Repositório do Instituto de Tecnologia de Alimentos - Instituto de Tecnologia de Alimentos (ITAL) |
repository.mail.fl_str_mv |
bjftsec@ital.sp.gov.br || bjftsec@ital.sp.gov.br |
_version_ |
1813095545618563072 |