Homemade Capillary Electrophoresis Coupled to a Mass Spectrometer
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNIFESP |
Texto Completo: | http://dx.doi.org/10.1080/10826076.2013.864982 http://repositorio.unifesp.br/handle/11600/38629 |
Resumo: | A system was developed in our laboratory to couple capillary electrophoresis with mass spectrometry. the capillary electrophoresis system was equipped with a high voltage supply, and a microcontroller with assembly language programming was developed for the computational control of the system. the MS system was a commercial Thermo Finningan LCQ ion trap mass spectrometer. the robustness of the coupled system was evaluated using standard protein samples (lysozyme, aprotinin, and bovine albumin) and tryptic digests of lysozyme. the system showed positive results in terms of robustness, allowing for the separation of digested proteins and the identification of 33% of the total amino acids in a protein (6 of the 18 expected peptides). the limit of detection was in the order of 1 picomole (signal-to-noise ratio), which was considered satisfactory for this system. the system shows high versatility in tandem coupling and combinations with other analytical procedures. |
id |
UFSP_c553029f21c19053f95334331379cb00 |
---|---|
oai_identifier_str |
oai:repositorio.unifesp.br/:11600/38629 |
network_acronym_str |
UFSP |
network_name_str |
Repositório Institucional da UNIFESP |
repository_id_str |
3465 |
spelling |
Homemade Capillary Electrophoresis Coupled to a Mass Spectrometermass spectrometryinstrumentationproteomicscapillary electrophoresisA system was developed in our laboratory to couple capillary electrophoresis with mass spectrometry. the capillary electrophoresis system was equipped with a high voltage supply, and a microcontroller with assembly language programming was developed for the computational control of the system. the MS system was a commercial Thermo Finningan LCQ ion trap mass spectrometer. the robustness of the coupled system was evaluated using standard protein samples (lysozyme, aprotinin, and bovine albumin) and tryptic digests of lysozyme. the system showed positive results in terms of robustness, allowing for the separation of digested proteins and the identification of 33% of the total amino acids in a protein (6 of the 18 expected peptides). the limit of detection was in the order of 1 picomole (signal-to-noise ratio), which was considered satisfactory for this system. the system shows high versatility in tandem coupling and combinations with other analytical procedures.Universidade Federal de São Paulo, Inst Ciencias Ambientais Quim & Farmaceut, Dept Ciencias Exatas & Terra Diadema, São Paulo, BrazilUniv São Paulo, Inst Quim Sao Carlos, São Paulo, BrazilUniversidade Federal de São Paulo, Inst Ciencias Ambientais Quim & Farmaceut, Dept Ciencias Exatas & Terra Diadema, São Paulo, BrazilWeb of ScienceFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Taylor & Francis IncUniversidade Federal de São Paulo (UNIFESP)Universidade de São Paulo (USP)Moraes, Janderson Aparecido de [UNIFESP]Carrilho, EmanuelAssunção, Nilson Antonio [UNIFESP]2016-01-24T14:39:54Z2016-01-24T14:39:54Z2015-01-02info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion36-43application/pdfhttp://dx.doi.org/10.1080/10826076.2013.864982Journal of Liquid Chromatography & Related Technologies. Philadelphia: Taylor & Francis Inc, v. 38, n. 1, p. 36-43, 2015.10.1080/10826076.2013.864982WOS000344381300006.pdf1082-6076http://repositorio.unifesp.br/handle/11600/38629WOS:000344381300006engJournal of Liquid Chromatography & Related Technologiesinfo:eu-repo/semantics/openAccesshttp://journalauthors.tandf.co.uk/permissions/reusingOwnWork.aspreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-08-08T09:07:13Zoai:repositorio.unifesp.br/:11600/38629Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-08-08T09:07:13Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false |
dc.title.none.fl_str_mv |
Homemade Capillary Electrophoresis Coupled to a Mass Spectrometer |
title |
Homemade Capillary Electrophoresis Coupled to a Mass Spectrometer |
spellingShingle |
Homemade Capillary Electrophoresis Coupled to a Mass Spectrometer Moraes, Janderson Aparecido de [UNIFESP] mass spectrometry instrumentation proteomics capillary electrophoresis |
title_short |
Homemade Capillary Electrophoresis Coupled to a Mass Spectrometer |
title_full |
Homemade Capillary Electrophoresis Coupled to a Mass Spectrometer |
title_fullStr |
Homemade Capillary Electrophoresis Coupled to a Mass Spectrometer |
title_full_unstemmed |
Homemade Capillary Electrophoresis Coupled to a Mass Spectrometer |
title_sort |
Homemade Capillary Electrophoresis Coupled to a Mass Spectrometer |
author |
Moraes, Janderson Aparecido de [UNIFESP] |
author_facet |
Moraes, Janderson Aparecido de [UNIFESP] Carrilho, Emanuel Assunção, Nilson Antonio [UNIFESP] |
author_role |
author |
author2 |
Carrilho, Emanuel Assunção, Nilson Antonio [UNIFESP] |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
Universidade Federal de São Paulo (UNIFESP) Universidade de São Paulo (USP) |
dc.contributor.author.fl_str_mv |
Moraes, Janderson Aparecido de [UNIFESP] Carrilho, Emanuel Assunção, Nilson Antonio [UNIFESP] |
dc.subject.por.fl_str_mv |
mass spectrometry instrumentation proteomics capillary electrophoresis |
topic |
mass spectrometry instrumentation proteomics capillary electrophoresis |
description |
A system was developed in our laboratory to couple capillary electrophoresis with mass spectrometry. the capillary electrophoresis system was equipped with a high voltage supply, and a microcontroller with assembly language programming was developed for the computational control of the system. the MS system was a commercial Thermo Finningan LCQ ion trap mass spectrometer. the robustness of the coupled system was evaluated using standard protein samples (lysozyme, aprotinin, and bovine albumin) and tryptic digests of lysozyme. the system showed positive results in terms of robustness, allowing for the separation of digested proteins and the identification of 33% of the total amino acids in a protein (6 of the 18 expected peptides). the limit of detection was in the order of 1 picomole (signal-to-noise ratio), which was considered satisfactory for this system. the system shows high versatility in tandem coupling and combinations with other analytical procedures. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-01-02 2016-01-24T14:39:54Z 2016-01-24T14:39:54Z |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1080/10826076.2013.864982 Journal of Liquid Chromatography & Related Technologies. Philadelphia: Taylor & Francis Inc, v. 38, n. 1, p. 36-43, 2015. 10.1080/10826076.2013.864982 WOS000344381300006.pdf 1082-6076 http://repositorio.unifesp.br/handle/11600/38629 WOS:000344381300006 |
url |
http://dx.doi.org/10.1080/10826076.2013.864982 http://repositorio.unifesp.br/handle/11600/38629 |
identifier_str_mv |
Journal of Liquid Chromatography & Related Technologies. Philadelphia: Taylor & Francis Inc, v. 38, n. 1, p. 36-43, 2015. 10.1080/10826076.2013.864982 WOS000344381300006.pdf 1082-6076 WOS:000344381300006 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Journal of Liquid Chromatography & Related Technologies |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess http://journalauthors.tandf.co.uk/permissions/reusingOwnWork.asp |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://journalauthors.tandf.co.uk/permissions/reusingOwnWork.asp |
dc.format.none.fl_str_mv |
36-43 application/pdf |
dc.publisher.none.fl_str_mv |
Taylor & Francis Inc |
publisher.none.fl_str_mv |
Taylor & Francis Inc |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UNIFESP instname:Universidade Federal de São Paulo (UNIFESP) instacron:UNIFESP |
instname_str |
Universidade Federal de São Paulo (UNIFESP) |
instacron_str |
UNIFESP |
institution |
UNIFESP |
reponame_str |
Repositório Institucional da UNIFESP |
collection |
Repositório Institucional da UNIFESP |
repository.name.fl_str_mv |
Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP) |
repository.mail.fl_str_mv |
biblioteca.csp@unifesp.br |
_version_ |
1814268347938766848 |