Validade e reprodutibilidade do COPD assessment test (CAT) em pacientes com bronquiectasia n??o-fibrose c??stica

Detalhes bibliográficos
Autor(a) principal: Castro, Rejane Agnelo Silva de
Data de Publicação: 2015
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da Uninove
Texto Completo: http://bibliotecatede.uninove.br/handle/tede/1817
Resumo: Introduction: Instruments to objectively assess the perception of symptoms in patients with BCQ are scarce. Patients with COPD and bronchiectasis (BCQ) share similar symptoms. Therefore, COPD Assesment Test (CAT), originally developed for COPD may be suitable for use in these patients. Objective: To validate and test the reproducibility of the CAT for non-cystic fibrosis (non???CF) bronchiectasis patients. Methods: Hundred patients (FEV1 52 ?? 25%; FVC 67 ?? 22%; 48 ?? 14 years; 42 males) underwent spirometry, cardiopulmonary exercise testing (peak workload and VO2), and shuttle walk test (ST). They answered the Saint George Respiratory Questionnaire (SGRQ) and the Medical Research Council (MRC) scale, and the CAT in two different days (CAT-1 and CAT-2). A pedometer recorded the No. of steps/day (NSD). Results: CAT showed a positive correlation with SGRQ domains (r = 0.74, p< 0.001) and MRC (r = 0.49, p< 0.001). A negative correlation was observed among CAT and lung function (FVC%: r= -0.33, p= 0.001; FEV1%: -0.28, p = 0.004), peak workload (r = -0.31, p = 0.001), VO2 (r = -0.44 p< 0.001), distance walked on ST (%, r= -0.46, p< 0.001), and NSD (r = -0.74, p< 0.001). There was an excellent reliability in the scores from CAT-1 and CAT-2 (21 ???13.25 ??? 26.75??? and (19 ???13 ??? 26.75???, respectively) with high intraclass correlation coefficient (ICC: 0.92 [95% CI: 0.83 ??? 0.96], p< 0.001). Conclusion: CAT is a valid instrument for measuring the impact of bronchiectasis in well-being and daily life of patients with BCT, and is a reproducible questionnaire.
id NOVE_ca1036b18080f9927245d2c7df776f59
oai_identifier_str oai:localhost:tede/1817
network_acronym_str NOVE
network_name_str Biblioteca Digital de Teses e Dissertações da Uninove
repository_id_str
spelling Lanza, Fernanda de CordobaCorso, Simone DalStelmach, RafaelLanza, Fernanda de CordobaGazzotti, Mariana RodriguesCorso, Simone Dalhttp://lattes.cnpq.br/9764782640766884Castro, Rejane Agnelo Silva de2018-06-19T18:12:45Z2015-11-27Castro, Rejane Agnelo Silva de. Validade e reprodutibilidade do COPD assessment test (CAT) em pacientes com bronquiectasia n??o-fibrose c??stica. 2015. 70 f. Disserta????o( Programa de P??s-Gradua????o em Ci??ncias da Reabilita????o) - Universidade Nove de Julho, S??o Paulo.http://bibliotecatede.uninove.br/handle/tede/1817Introduction: Instruments to objectively assess the perception of symptoms in patients with BCQ are scarce. Patients with COPD and bronchiectasis (BCQ) share similar symptoms. Therefore, COPD Assesment Test (CAT), originally developed for COPD may be suitable for use in these patients. Objective: To validate and test the reproducibility of the CAT for non-cystic fibrosis (non???CF) bronchiectasis patients. Methods: Hundred patients (FEV1 52 ?? 25%; FVC 67 ?? 22%; 48 ?? 14 years; 42 males) underwent spirometry, cardiopulmonary exercise testing (peak workload and VO2), and shuttle walk test (ST). They answered the Saint George Respiratory Questionnaire (SGRQ) and the Medical Research Council (MRC) scale, and the CAT in two different days (CAT-1 and CAT-2). A pedometer recorded the No. of steps/day (NSD). Results: CAT showed a positive correlation with SGRQ domains (r = 0.74, p< 0.001) and MRC (r = 0.49, p< 0.001). A negative correlation was observed among CAT and lung function (FVC%: r= -0.33, p= 0.001; FEV1%: -0.28, p = 0.004), peak workload (r = -0.31, p = 0.001), VO2 (r = -0.44 p< 0.001), distance walked on ST (%, r= -0.46, p< 0.001), and NSD (r = -0.74, p< 0.001). There was an excellent reliability in the scores from CAT-1 and CAT-2 (21 ???13.25 ??? 26.75??? and (19 ???13 ??? 26.75???, respectively) with high intraclass correlation coefficient (ICC: 0.92 [95% CI: 0.83 ??? 0.96], p< 0.001). Conclusion: CAT is a valid instrument for measuring the impact of bronchiectasis in well-being and daily life of patients with BCT, and is a reproducible questionnaire.Introdu????o: Instrumentos que avaliam objetivamente a percep????o dos sintomas em pacientes com BCQ s??o escassos. Pacientes com DPOC e bronquiectasia (BCQ) compartilham sintomas semelhantes. Portanto, o COPD Assesment Test (CAT), originalmente desenvolvido para DPOC, pode ser adequado para uso nesses pacientes. Objetivo: Validar e testar a reprodutibilidade do CAT para BCQ. M??todos: 100 pacientes (42 homens, 48 ?? 14 anos, VEF1 52 ?? 25% prev, CVF 67 ?? 22% prev) foram submetidos ?? espirometria, shuttle walk test incremental (SWTI) e teste de exerc??cio cardiopulmonar exerc??cio (TECP, carga e VO2 pico). Eles responderam ao Saint George???s Respiratory Questionnaire (SGRQ), ?? escala de dispneia Medical Research Council (MRC) e ao CAT (este em dois dias diferentes CAT-1 e CAT-2). O n??mero de passos por dia (NP) foi registrado por ped??metro. Resultados: Os escores do CAT correlacionaram-se positivamente com os escores dos dom??nios SGRQ (r de 0,74, a p< 0,001) e MRC (r= 0,49, p= 0,001). Foi observada correla????o negativa entre o CAT e a fun????o pulmonar (CVF%: r= -0,33, p= 0,001; VEF1%: -0,28, p= 0,004), carga (r= -0,31, p= 0,001), VO2 (r= -0,44 p< 0,001), dist??ncia no SWTI (r= -0,46, p< 0,001), e NP (r= -0,42, p< 0,001). Houve excelente reprodutibilidade entre os escores de CAT-1 e CAT-2 (21 ???13,25 ??? 26??? e (19 ???13 ??? 26,75???, respectivamente), com elevados coeficiente de correla????o intraclasse (ICC: 0,91 [95% CI: 0,87-0,94], p<0,001). Conclus??o: CAT ?? um instrumento v??lido para medir o impacto da BCQ no bem-estar na vida di??ria dos pacientes com BCQ, e ?? um question??rio reprodut??vel.Submitted by Nadir Basilio (nadirsb@uninove.br) on 2018-06-19T18:12:45Z No. of bitstreams: 1 Rejane Agnelo Silva de Castro.pdf: 1052641 bytes, checksum: 1f8691a5b4f1dcb3d43ec9c6aa9e4345 (MD5)Made available in DSpace on 2018-06-19T18:12:45Z (GMT). No. of bitstreams: 1 Rejane Agnelo Silva de Castro.pdf: 1052641 bytes, checksum: 1f8691a5b4f1dcb3d43ec9c6aa9e4345 (MD5) Previous issue date: 2015-11-27application/pdfporUniversidade Nove de JulhoPrograma de P??s-Gradua????o em Ci??ncias da Reabilita????oUNINOVEBrasilSa??debronquiectasiaqualidade de vidaquestion??riosbronchiectasisquality of lifequestionnaireCIENCIAS DA SAUDEValidade e reprodutibilidade do COPD assessment test (CAT) em pacientes com bronquiectasia n??o-fibrose c??sticaValidity and reproducibility of COPD assessment test (CAT) in patients with non-bronchiectasis cystic fibrosisinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis8765449414823306929600info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da Uninoveinstname:Universidade Nove de Julho (UNINOVE)instacron:UNINOVEORIGINALRejane Agnelo Silva de Castro.pdfRejane Agnelo Silva de Castro.pdfapplication/pdf1052641http://localhost:8080/tede/bitstream/tede/1817/2/Rejane+Agnelo+Silva+de+Castro.pdf1f8691a5b4f1dcb3d43ec9c6aa9e4345MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-82165http://localhost:8080/tede/bitstream/tede/1817/1/license.txtbd3efa91386c1718a7f26a329fdcb468MD51tede/18172018-06-19 15:12:45.07oai:localhost: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Biblioteca Digital de Teses e Dissertaçõeshttp://bibliotecatede.uninove.br/PRIhttp://bibliotecatede.uninove.br/oai/requestbibliotecatede@uninove.br||bibliotecatede@uninove.bropendoar:2018-06-19T18:12:45Biblioteca Digital de Teses e Dissertações da Uninove - Universidade Nove de Julho (UNINOVE)false
dc.title.por.fl_str_mv Validade e reprodutibilidade do COPD assessment test (CAT) em pacientes com bronquiectasia n??o-fibrose c??stica
dc.title.alternative.eng.fl_str_mv Validity and reproducibility of COPD assessment test (CAT) in patients with non-bronchiectasis cystic fibrosis
title Validade e reprodutibilidade do COPD assessment test (CAT) em pacientes com bronquiectasia n??o-fibrose c??stica
spellingShingle Validade e reprodutibilidade do COPD assessment test (CAT) em pacientes com bronquiectasia n??o-fibrose c??stica
Castro, Rejane Agnelo Silva de
bronquiectasia
qualidade de vida
question??rios
bronchiectasis
quality of life
questionnaire
CIENCIAS DA SAUDE
title_short Validade e reprodutibilidade do COPD assessment test (CAT) em pacientes com bronquiectasia n??o-fibrose c??stica
title_full Validade e reprodutibilidade do COPD assessment test (CAT) em pacientes com bronquiectasia n??o-fibrose c??stica
title_fullStr Validade e reprodutibilidade do COPD assessment test (CAT) em pacientes com bronquiectasia n??o-fibrose c??stica
title_full_unstemmed Validade e reprodutibilidade do COPD assessment test (CAT) em pacientes com bronquiectasia n??o-fibrose c??stica
title_sort Validade e reprodutibilidade do COPD assessment test (CAT) em pacientes com bronquiectasia n??o-fibrose c??stica
author Castro, Rejane Agnelo Silva de
author_facet Castro, Rejane Agnelo Silva de
author_role author
dc.contributor.advisor1.fl_str_mv Lanza, Fernanda de Cordoba
dc.contributor.advisor-co1.fl_str_mv Corso, Simone Dal
dc.contributor.advisor-co2.fl_str_mv Stelmach, Rafael
dc.contributor.referee1.fl_str_mv Lanza, Fernanda de Cordoba
dc.contributor.referee2.fl_str_mv Gazzotti, Mariana Rodrigues
dc.contributor.referee3.fl_str_mv Corso, Simone Dal
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/9764782640766884
dc.contributor.author.fl_str_mv Castro, Rejane Agnelo Silva de
contributor_str_mv Lanza, Fernanda de Cordoba
Corso, Simone Dal
Stelmach, Rafael
Lanza, Fernanda de Cordoba
Gazzotti, Mariana Rodrigues
Corso, Simone Dal
dc.subject.por.fl_str_mv bronquiectasia
qualidade de vida
question??rios
topic bronquiectasia
qualidade de vida
question??rios
bronchiectasis
quality of life
questionnaire
CIENCIAS DA SAUDE
dc.subject.eng.fl_str_mv bronchiectasis
quality of life
questionnaire
dc.subject.cnpq.fl_str_mv CIENCIAS DA SAUDE
description Introduction: Instruments to objectively assess the perception of symptoms in patients with BCQ are scarce. Patients with COPD and bronchiectasis (BCQ) share similar symptoms. Therefore, COPD Assesment Test (CAT), originally developed for COPD may be suitable for use in these patients. Objective: To validate and test the reproducibility of the CAT for non-cystic fibrosis (non???CF) bronchiectasis patients. Methods: Hundred patients (FEV1 52 ?? 25%; FVC 67 ?? 22%; 48 ?? 14 years; 42 males) underwent spirometry, cardiopulmonary exercise testing (peak workload and VO2), and shuttle walk test (ST). They answered the Saint George Respiratory Questionnaire (SGRQ) and the Medical Research Council (MRC) scale, and the CAT in two different days (CAT-1 and CAT-2). A pedometer recorded the No. of steps/day (NSD). Results: CAT showed a positive correlation with SGRQ domains (r = 0.74, p< 0.001) and MRC (r = 0.49, p< 0.001). A negative correlation was observed among CAT and lung function (FVC%: r= -0.33, p= 0.001; FEV1%: -0.28, p = 0.004), peak workload (r = -0.31, p = 0.001), VO2 (r = -0.44 p< 0.001), distance walked on ST (%, r= -0.46, p< 0.001), and NSD (r = -0.74, p< 0.001). There was an excellent reliability in the scores from CAT-1 and CAT-2 (21 ???13.25 ??? 26.75??? and (19 ???13 ??? 26.75???, respectively) with high intraclass correlation coefficient (ICC: 0.92 [95% CI: 0.83 ??? 0.96], p< 0.001). Conclusion: CAT is a valid instrument for measuring the impact of bronchiectasis in well-being and daily life of patients with BCT, and is a reproducible questionnaire.
publishDate 2015
dc.date.issued.fl_str_mv 2015-11-27
dc.date.accessioned.fl_str_mv 2018-06-19T18:12:45Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv Castro, Rejane Agnelo Silva de. Validade e reprodutibilidade do COPD assessment test (CAT) em pacientes com bronquiectasia n??o-fibrose c??stica. 2015. 70 f. Disserta????o( Programa de P??s-Gradua????o em Ci??ncias da Reabilita????o) - Universidade Nove de Julho, S??o Paulo.
dc.identifier.uri.fl_str_mv http://bibliotecatede.uninove.br/handle/tede/1817
identifier_str_mv Castro, Rejane Agnelo Silva de. Validade e reprodutibilidade do COPD assessment test (CAT) em pacientes com bronquiectasia n??o-fibrose c??stica. 2015. 70 f. Disserta????o( Programa de P??s-Gradua????o em Ci??ncias da Reabilita????o) - Universidade Nove de Julho, S??o Paulo.
url http://bibliotecatede.uninove.br/handle/tede/1817
dc.language.iso.fl_str_mv por
language por
dc.relation.cnpq.fl_str_mv 8765449414823306929
dc.relation.confidence.fl_str_mv 600
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Nove de Julho
dc.publisher.program.fl_str_mv Programa de P??s-Gradua????o em Ci??ncias da Reabilita????o
dc.publisher.initials.fl_str_mv UNINOVE
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Sa??de
publisher.none.fl_str_mv Universidade Nove de Julho
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da Uninove
instname:Universidade Nove de Julho (UNINOVE)
instacron:UNINOVE
instname_str Universidade Nove de Julho (UNINOVE)
instacron_str UNINOVE
institution UNINOVE
reponame_str Biblioteca Digital de Teses e Dissertações da Uninove
collection Biblioteca Digital de Teses e Dissertações da Uninove
bitstream.url.fl_str_mv http://localhost:8080/tede/bitstream/tede/1817/2/Rejane+Agnelo+Silva+de+Castro.pdf
http://localhost:8080/tede/bitstream/tede/1817/1/license.txt
bitstream.checksum.fl_str_mv 1f8691a5b4f1dcb3d43ec9c6aa9e4345
bd3efa91386c1718a7f26a329fdcb468
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da Uninove - Universidade Nove de Julho (UNINOVE)
repository.mail.fl_str_mv bibliotecatede@uninove.br||bibliotecatede@uninove.br
_version_ 1811016874404610048