The effect of thermo-cycling on flexural strength of laboratorial resins

Detalhes bibliográficos
Autor(a) principal: Oliveira, Karla Mychellyne Costa
Data de Publicação: 2008
Outros Autores: Castilho, Anderson Almeida, Marocho, Susana María Salazar, Pereira, Sarina Maciel Braga, Vásquez, Vanessa Zulema Ccahuana, Bottino, Marco Antonio
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista odonto ciência (Online)
Texto Completo: https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2448
Resumo: Introduction: A new laboratorial resin generation that content ceramic microparticles in its composition has been introduced in the market with the purpose to improve its mechanical properties. Objective: The objective of this study was to evaluate the effect of the thermocycling in the flexural strength of three laboratorial resins. Method: Forty-eight specimens with measures of 2 mm × 2 mm × 25 mm were made using laboratorial resins: G1 - RESILAB MASTER (Wilcos, Brazil), G2 - VITA VM LC (Vita Zanhfabrik, Germany) and G3 - VITA ZETA (Vita Zanhfabrik, Germany). After their confection, half of each group was submitted to 3000 thermal-cycles (5ºC/55ºC ± 1, with rinse bath of 30 s). The mechanical essays were done in Universal essay machine EMIC with the loading capacity of 100 kg and the equispeed of 0,5 mm/min. Results: The obtained data was analyzed statistically by the ANOVA test (two-way) and Turkey’s test (p < 0,05). The averages (± DP) observed for the groups without cycles were: G1(112,6 ± 25,39), G2(116,5 ± 18,51) and G3(136,1 ± 24,34); and for the groups with cycles: G1(91,8 ± 18,86), G2(101,9 ± 20,61) and G3 89,9 ± 23,05). Conclusion: It was concluded that the decrease in the flexural strength in MPa is directly dependent on the thermo-cycling in the tested groups, being that the highest values were obtained by VM LC resin. However, in the group without thermo-cycling the VITA ZETA showed the highest values. UNITERMS: three point bending; thermo-cycling; composite resin.
id PUC_RS-22_032b012b9c34e36dbb2f1c8a9421582b
oai_identifier_str oai:ojs.revistaseletronicas.pucrs.br:article/2448
network_acronym_str PUC_RS-22
network_name_str Revista odonto ciência (Online)
repository_id_str
spelling The effect of thermo-cycling on flexural strength of laboratorial resinsInfluência da ciclagem térmica na resistência à flexão de resinas laboratoriaisthree point bendingthermo-cyclingcomposite resinIndirect dental compositesIntroduction: A new laboratorial resin generation that content ceramic microparticles in its composition has been introduced in the market with the purpose to improve its mechanical properties. Objective: The objective of this study was to evaluate the effect of the thermocycling in the flexural strength of three laboratorial resins. Method: Forty-eight specimens with measures of 2 mm × 2 mm × 25 mm were made using laboratorial resins: G1 - RESILAB MASTER (Wilcos, Brazil), G2 - VITA VM LC (Vita Zanhfabrik, Germany) and G3 - VITA ZETA (Vita Zanhfabrik, Germany). After their confection, half of each group was submitted to 3000 thermal-cycles (5ºC/55ºC ± 1, with rinse bath of 30 s). The mechanical essays were done in Universal essay machine EMIC with the loading capacity of 100 kg and the equispeed of 0,5 mm/min. Results: The obtained data was analyzed statistically by the ANOVA test (two-way) and Turkey’s test (p < 0,05). The averages (± DP) observed for the groups without cycles were: G1(112,6 ± 25,39), G2(116,5 ± 18,51) and G3(136,1 ± 24,34); and for the groups with cycles: G1(91,8 ± 18,86), G2(101,9 ± 20,61) and G3 89,9 ± 23,05). Conclusion: It was concluded that the decrease in the flexural strength in MPa is directly dependent on the thermo-cycling in the tested groups, being that the highest values were obtained by VM LC resin. However, in the group without thermo-cycling the VITA ZETA showed the highest values. UNITERMS: three point bending; thermo-cycling; composite resin.Introdução: Uma nova geração de resinas laboratoriais contendo micro-partículas cerâmicas em sua composição tem sido introduzida no mercado com a finalidade de melhorar suas propriedades mecânicas. Objetivo: O objetivo deste estudo foi avaliar o efeito da termociclagem na resistência à flexão de três resinas laboratoriais. Materiais e método: Foram confeccionadas 48 barras com medidas de 2 mm × 2 mm × 25 mm, utilizando as resinas laboratoriais: G1 - RESILAB MASTER (Wilcos, Brasil), G2 - VITA VM LC (Vita Zanhfabrik, Germany), G3 - VITA ZETA LC (Vita Zanhfabrik, Germany). A metade das barras de cada grupo foi submetida a 3000 ciclos térmicos (5ºC/55ºC ± 1, com banhos de 30 s). Os ensaios mecânicos foram efetuados em máquina de ensaio universal EMIC com capacidade de carga de 100 kg e velocidade de 0,5 mm/min. Resultados: Os dados obtidos foram analisados estatisticamente pelo teste de ANOVA (two-way) e Tukey (p < 0,05). As médias (± DP) observadas para os grupos sem ciclagem foram: G1(112,6 ± 25,39), G2(116,5 ± 18,51) e G3(136,1 ± 24,34); e para os grupos com ciclagem: G1(91,8 ± 18,86), G2(101,9 ± 20,61) e G3(89,9 ± 23,05). Conclusão: Concluiu-se que a diminuição da resistência à flexão em MPa está diretamente dependente da ciclagem térmica nos grupos testados, sendo que os maiores valores foram obtidos pela resina VITA VM LC. Entretanto, na condição sem ciclagem térmica a VITA ZETA apresentou os maiores valores. UNITERMOS: resistência à flexão; termociclagem; resinas compostas.EDIPUCRS - Editora Universitária da PUCRS2008-01-11info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articlelaboratory; material testing; experimentalapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2448Revista Odonto Ciência; Vol. 22 No. 58 (2007); 364 - 370Revista Odonto Ciência; v. 22 n. 58 (2007); 364 - 3701980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2448/1922Oliveira, Karla Mychellyne CostaCastilho, Anderson AlmeidaMarocho, Susana María SalazarPereira, Sarina Maciel BragaVásquez, Vanessa Zulema CcahuanaBottino, Marco Antonioinfo:eu-repo/semantics/openAccess2013-11-18T11:02:31Zoai:ojs.revistaseletronicas.pucrs.br:article/2448Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-18T11:02:31Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.none.fl_str_mv The effect of thermo-cycling on flexural strength of laboratorial resins
Influência da ciclagem térmica na resistência à flexão de resinas laboratoriais
title The effect of thermo-cycling on flexural strength of laboratorial resins
spellingShingle The effect of thermo-cycling on flexural strength of laboratorial resins
Oliveira, Karla Mychellyne Costa
three point bending
thermo-cycling
composite resin
Indirect dental composites
title_short The effect of thermo-cycling on flexural strength of laboratorial resins
title_full The effect of thermo-cycling on flexural strength of laboratorial resins
title_fullStr The effect of thermo-cycling on flexural strength of laboratorial resins
title_full_unstemmed The effect of thermo-cycling on flexural strength of laboratorial resins
title_sort The effect of thermo-cycling on flexural strength of laboratorial resins
author Oliveira, Karla Mychellyne Costa
author_facet Oliveira, Karla Mychellyne Costa
Castilho, Anderson Almeida
Marocho, Susana María Salazar
Pereira, Sarina Maciel Braga
Vásquez, Vanessa Zulema Ccahuana
Bottino, Marco Antonio
author_role author
author2 Castilho, Anderson Almeida
Marocho, Susana María Salazar
Pereira, Sarina Maciel Braga
Vásquez, Vanessa Zulema Ccahuana
Bottino, Marco Antonio
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Oliveira, Karla Mychellyne Costa
Castilho, Anderson Almeida
Marocho, Susana María Salazar
Pereira, Sarina Maciel Braga
Vásquez, Vanessa Zulema Ccahuana
Bottino, Marco Antonio
dc.subject.por.fl_str_mv three point bending
thermo-cycling
composite resin
Indirect dental composites
topic three point bending
thermo-cycling
composite resin
Indirect dental composites
description Introduction: A new laboratorial resin generation that content ceramic microparticles in its composition has been introduced in the market with the purpose to improve its mechanical properties. Objective: The objective of this study was to evaluate the effect of the thermocycling in the flexural strength of three laboratorial resins. Method: Forty-eight specimens with measures of 2 mm × 2 mm × 25 mm were made using laboratorial resins: G1 - RESILAB MASTER (Wilcos, Brazil), G2 - VITA VM LC (Vita Zanhfabrik, Germany) and G3 - VITA ZETA (Vita Zanhfabrik, Germany). After their confection, half of each group was submitted to 3000 thermal-cycles (5ºC/55ºC ± 1, with rinse bath of 30 s). The mechanical essays were done in Universal essay machine EMIC with the loading capacity of 100 kg and the equispeed of 0,5 mm/min. Results: The obtained data was analyzed statistically by the ANOVA test (two-way) and Turkey’s test (p < 0,05). The averages (± DP) observed for the groups without cycles were: G1(112,6 ± 25,39), G2(116,5 ± 18,51) and G3(136,1 ± 24,34); and for the groups with cycles: G1(91,8 ± 18,86), G2(101,9 ± 20,61) and G3 89,9 ± 23,05). Conclusion: It was concluded that the decrease in the flexural strength in MPa is directly dependent on the thermo-cycling in the tested groups, being that the highest values were obtained by VM LC resin. However, in the group without thermo-cycling the VITA ZETA showed the highest values. UNITERMS: three point bending; thermo-cycling; composite resin.
publishDate 2008
dc.date.none.fl_str_mv 2008-01-11
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Peer-reviewed Article
laboratory; material testing; experimental
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2448
url https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2448
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/2448/1922
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
dc.source.none.fl_str_mv Revista Odonto Ciência; Vol. 22 No. 58 (2007); 364 - 370
Revista Odonto Ciência; v. 22 n. 58 (2007); 364 - 370
1980-6523
0102-9460
reponame:Revista odonto ciência (Online)
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Revista odonto ciência (Online)
collection Revista odonto ciência (Online)
repository.name.fl_str_mv Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv ||odontociencia@pucrs.br
_version_ 1754820874191503360