Preflaring effects on the accuracy of three electronic apex locators

Detalhes bibliográficos
Autor(a) principal: Morgental, Renata Dornelles
Data de Publicação: 2011
Outros Autores: Vier-Pelisser, Fabiana Vieira, Luisi, Simone Bonato, Cogo, Deborah Meirelles, Kopper, Patrícia Maria Poli
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista odonto ciência (Online)
Texto Completo: https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/9806
Resumo: Purpose: To compare the accuracy of three electronic apex locators (EALs) and evaluate the influence of cervical preflaring in them. Methods: The working length (WL) of thirty extracted human mandibular incisors was determined visually. All teeth were mounted in conducting medium and tested with: Novapex, Mini Apex Locator and Propex II. The electronic WL was determined before and after preflaring with LA Axxess burs. Differences between the electronic and visual WL were calculated and analyzed by Friedman and Wilcoxon tests. Radiographs were taken using the electronic WL of each EAL and the distance between the instrument tip and the radiographic apical vertex was measured. This value was compared to a reference or ideal value (1 mm) by one-sample t test. Results: The Novapex was the most accurate EAL before and after the preflaring procedure, which was confirmed by the radiographic analysis. All EALs tested increased their accuracy after preflaring, but no significant difference was noted for the Novapex. Conclusion: The Novapex was more accurate compared to the Mini Apex and Propex II. Preflaring procedure was advantageous for all EALs.
id PUC_RS-22_60db0e6deaeaf4c45e2115c58ff958fc
oai_identifier_str oai:ojs.revistaseletronicas.pucrs.br:article/9806
network_acronym_str PUC_RS-22
network_name_str Revista odonto ciência (Online)
repository_id_str
spelling Preflaring effects on the accuracy of three electronic apex locatorsEfeitos do pré-alargamento na acurácia de três localizadores apicais eletrônicosEndodonticsroot canal preparationtooth apexEndodontiapreparo do canal radicularápice dentalPurpose: To compare the accuracy of three electronic apex locators (EALs) and evaluate the influence of cervical preflaring in them. Methods: The working length (WL) of thirty extracted human mandibular incisors was determined visually. All teeth were mounted in conducting medium and tested with: Novapex, Mini Apex Locator and Propex II. The electronic WL was determined before and after preflaring with LA Axxess burs. Differences between the electronic and visual WL were calculated and analyzed by Friedman and Wilcoxon tests. Radiographs were taken using the electronic WL of each EAL and the distance between the instrument tip and the radiographic apical vertex was measured. This value was compared to a reference or ideal value (1 mm) by one-sample t test. Results: The Novapex was the most accurate EAL before and after the preflaring procedure, which was confirmed by the radiographic analysis. All EALs tested increased their accuracy after preflaring, but no significant difference was noted for the Novapex. Conclusion: The Novapex was more accurate compared to the Mini Apex and Propex II. Preflaring procedure was advantageous for all EALs.Objetivo: Comparar três localizadores apicais eletrônicos (LAEs) e avaliar a influência do pré-alargamento cervical na sua acurácia. Métodos: O comprimento de trabalho (CT) de trinta incisivos inferiores humanos extraídos foi determinado visualmente. Todos os dentes foram montados em um meio condutor e testados com Novapex, Mini Apex Locator e Propex II. O CT eletrônico foi determinado antes e após pré-alargamento com brocas LA Axxess. As diferenças entre o CT eletrônico e visual foram calculadas e analisadas pelos testes de Friedman e Wilcoxon. Radiografias foram realizadas com o CT eletrônico de cada LAE e a distância da ponta do instrumento ao vértice radiográfico foi mensurada. Este valor foi comparado com um valor de referência ou ideal (1 mm) pelo teste t para uma amostra. Resultados: Novapex foi o LAE mais preciso antes e após procedimento de pré-alargamento, o que foi confirmado pela análise radiográfica. Todos os LAEs testados aumentaram sua acurácia após pré-alargamento, mas não foi observada diferença significativa para o Novapex. Conclusão: Novapex foi mais preciso que Mini Apex e Propex II. O procedimento de pré-alargamento foi vantajoso para todos os LAEs.EDIPUCRS - Editora Universitária da PUCRS2011-12-13info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articleapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/9806Revista Odonto Ciência; Vol. 26 No. 4 (2011); 331 - 335Revista Odonto Ciência; v. 26 n. 4 (2011); 331 - 3351980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/9806/7498Morgental, Renata DornellesVier-Pelisser, Fabiana VieiraLuisi, Simone BonatoCogo, Deborah MeirellesKopper, Patrícia Maria Poliinfo:eu-repo/semantics/openAccess2013-11-11T11:44:27Zoai:ojs.revistaseletronicas.pucrs.br:article/9806Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-11T11:44:27Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.none.fl_str_mv Preflaring effects on the accuracy of three electronic apex locators
Efeitos do pré-alargamento na acurácia de três localizadores apicais eletrônicos
title Preflaring effects on the accuracy of three electronic apex locators
spellingShingle Preflaring effects on the accuracy of three electronic apex locators
Morgental, Renata Dornelles
Endodontics
root canal preparation
tooth apex
Endodontia
preparo do canal radicular
ápice dental
title_short Preflaring effects on the accuracy of three electronic apex locators
title_full Preflaring effects on the accuracy of three electronic apex locators
title_fullStr Preflaring effects on the accuracy of three electronic apex locators
title_full_unstemmed Preflaring effects on the accuracy of three electronic apex locators
title_sort Preflaring effects on the accuracy of three electronic apex locators
author Morgental, Renata Dornelles
author_facet Morgental, Renata Dornelles
Vier-Pelisser, Fabiana Vieira
Luisi, Simone Bonato
Cogo, Deborah Meirelles
Kopper, Patrícia Maria Poli
author_role author
author2 Vier-Pelisser, Fabiana Vieira
Luisi, Simone Bonato
Cogo, Deborah Meirelles
Kopper, Patrícia Maria Poli
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Morgental, Renata Dornelles
Vier-Pelisser, Fabiana Vieira
Luisi, Simone Bonato
Cogo, Deborah Meirelles
Kopper, Patrícia Maria Poli
dc.subject.por.fl_str_mv Endodontics
root canal preparation
tooth apex
Endodontia
preparo do canal radicular
ápice dental
topic Endodontics
root canal preparation
tooth apex
Endodontia
preparo do canal radicular
ápice dental
description Purpose: To compare the accuracy of three electronic apex locators (EALs) and evaluate the influence of cervical preflaring in them. Methods: The working length (WL) of thirty extracted human mandibular incisors was determined visually. All teeth were mounted in conducting medium and tested with: Novapex, Mini Apex Locator and Propex II. The electronic WL was determined before and after preflaring with LA Axxess burs. Differences between the electronic and visual WL were calculated and analyzed by Friedman and Wilcoxon tests. Radiographs were taken using the electronic WL of each EAL and the distance between the instrument tip and the radiographic apical vertex was measured. This value was compared to a reference or ideal value (1 mm) by one-sample t test. Results: The Novapex was the most accurate EAL before and after the preflaring procedure, which was confirmed by the radiographic analysis. All EALs tested increased their accuracy after preflaring, but no significant difference was noted for the Novapex. Conclusion: The Novapex was more accurate compared to the Mini Apex and Propex II. Preflaring procedure was advantageous for all EALs.
publishDate 2011
dc.date.none.fl_str_mv 2011-12-13
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Peer-reviewed Article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/9806
url https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/9806
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/9806/7498
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
dc.source.none.fl_str_mv Revista Odonto Ciência; Vol. 26 No. 4 (2011); 331 - 335
Revista Odonto Ciência; v. 26 n. 4 (2011); 331 - 335
1980-6523
0102-9460
reponame:Revista odonto ciência (Online)
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Revista odonto ciência (Online)
collection Revista odonto ciência (Online)
repository.name.fl_str_mv Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv ||odontociencia@pucrs.br
_version_ 1754820875905925120