Effect of pre-flaring and file size on the accuracy of two electronic apex locators
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of applied oral science (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572012000500008 |
Resumo: | OBJECTIVE: This ex vivo study evaluated the effect of pre-flaring and file size on the accuracy of the Root ZX and Novapex electronic apex locators (EALs). MATERIAL AND METHODS: The actual working length (WL) was set 1 mm short of the apical foramen in the palatal root canals of 24 extracted maxillary molars. The teeth were embedded in an alginate mold, and two examiners performed the electronic measurements using #10, #15, and #20 K-files. The files were inserted into the root canals until the "0.0" or "APEX" signals were observed on the LED or display screens for the Novapex and Root ZX, respectively, retracting to the 1.0 mark. The measurements were repeated after the preflaring using the S1 and SX Pro-Taper instruments. Two measurements were performed for each condition and the means were used. Intra-class correlation coefficients (ICCs) were calculated to verify the intra- and inter-examiner agreement. The mean differences between the WL and electronic length values were analyzed by the three-way ANOVA test (p<0.05). RESULTS: ICCs were high (>0.8) and the results demonstrated a similar accuracy for both EALs (p>0.05). Statistically significant accurate measurements were verified in the pre-flared canals, except for the Novapex using a #20 K-file. CONCLUSIONS: The tested EALs showed acceptable accuracy, whereas the pre-flaring procedure revealed a more significant effect than the used file size. |
id |
USP-17_58b4d5b4610f9456239a7fc0a5fab6c9 |
---|---|
oai_identifier_str |
oai:scielo:S1678-77572012000500008 |
network_acronym_str |
USP-17 |
network_name_str |
Journal of applied oral science (Online) |
repository_id_str |
|
spelling |
Effect of pre-flaring and file size on the accuracy of two electronic apex locatorsEndodonticsOdontometryRoot canal preparationTooth apexOBJECTIVE: This ex vivo study evaluated the effect of pre-flaring and file size on the accuracy of the Root ZX and Novapex electronic apex locators (EALs). MATERIAL AND METHODS: The actual working length (WL) was set 1 mm short of the apical foramen in the palatal root canals of 24 extracted maxillary molars. The teeth were embedded in an alginate mold, and two examiners performed the electronic measurements using #10, #15, and #20 K-files. The files were inserted into the root canals until the "0.0" or "APEX" signals were observed on the LED or display screens for the Novapex and Root ZX, respectively, retracting to the 1.0 mark. The measurements were repeated after the preflaring using the S1 and SX Pro-Taper instruments. Two measurements were performed for each condition and the means were used. Intra-class correlation coefficients (ICCs) were calculated to verify the intra- and inter-examiner agreement. The mean differences between the WL and electronic length values were analyzed by the three-way ANOVA test (p<0.05). RESULTS: ICCs were high (>0.8) and the results demonstrated a similar accuracy for both EALs (p>0.05). Statistically significant accurate measurements were verified in the pre-flared canals, except for the Novapex using a #20 K-file. CONCLUSIONS: The tested EALs showed acceptable accuracy, whereas the pre-flaring procedure revealed a more significant effect than the used file size.Faculdade De Odontologia De Bauru - USP2012-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572012000500008Journal of Applied Oral Science v.20 n.5 2012reponame:Journal of applied oral science (Online)instname:Universidade de São Paulo (USP)instacron:USP10.1590/S1678-77572012000500008info:eu-repo/semantics/openAccessBrito-Júnior,ManoelCamilo,Carla CristinaMoreira-Júnior,GilPecora,Jesus DjalmaSousa-Neto,Manoel Damiãoeng2012-11-06T00:00:00Zoai:scielo:S1678-77572012000500008Revistahttp://www.scielo.br/jaosPUBhttps://old.scielo.br/oai/scielo-oai.php||jaos@usp.br1678-77651678-7757opendoar:2012-11-06T00:00Journal of applied oral science (Online) - Universidade de São Paulo (USP)false |
dc.title.none.fl_str_mv |
Effect of pre-flaring and file size on the accuracy of two electronic apex locators |
title |
Effect of pre-flaring and file size on the accuracy of two electronic apex locators |
spellingShingle |
Effect of pre-flaring and file size on the accuracy of two electronic apex locators Brito-Júnior,Manoel Endodontics Odontometry Root canal preparation Tooth apex |
title_short |
Effect of pre-flaring and file size on the accuracy of two electronic apex locators |
title_full |
Effect of pre-flaring and file size on the accuracy of two electronic apex locators |
title_fullStr |
Effect of pre-flaring and file size on the accuracy of two electronic apex locators |
title_full_unstemmed |
Effect of pre-flaring and file size on the accuracy of two electronic apex locators |
title_sort |
Effect of pre-flaring and file size on the accuracy of two electronic apex locators |
author |
Brito-Júnior,Manoel |
author_facet |
Brito-Júnior,Manoel Camilo,Carla Cristina Moreira-Júnior,Gil Pecora,Jesus Djalma Sousa-Neto,Manoel Damião |
author_role |
author |
author2 |
Camilo,Carla Cristina Moreira-Júnior,Gil Pecora,Jesus Djalma Sousa-Neto,Manoel Damião |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Brito-Júnior,Manoel Camilo,Carla Cristina Moreira-Júnior,Gil Pecora,Jesus Djalma Sousa-Neto,Manoel Damião |
dc.subject.por.fl_str_mv |
Endodontics Odontometry Root canal preparation Tooth apex |
topic |
Endodontics Odontometry Root canal preparation Tooth apex |
description |
OBJECTIVE: This ex vivo study evaluated the effect of pre-flaring and file size on the accuracy of the Root ZX and Novapex electronic apex locators (EALs). MATERIAL AND METHODS: The actual working length (WL) was set 1 mm short of the apical foramen in the palatal root canals of 24 extracted maxillary molars. The teeth were embedded in an alginate mold, and two examiners performed the electronic measurements using #10, #15, and #20 K-files. The files were inserted into the root canals until the "0.0" or "APEX" signals were observed on the LED or display screens for the Novapex and Root ZX, respectively, retracting to the 1.0 mark. The measurements were repeated after the preflaring using the S1 and SX Pro-Taper instruments. Two measurements were performed for each condition and the means were used. Intra-class correlation coefficients (ICCs) were calculated to verify the intra- and inter-examiner agreement. The mean differences between the WL and electronic length values were analyzed by the three-way ANOVA test (p<0.05). RESULTS: ICCs were high (>0.8) and the results demonstrated a similar accuracy for both EALs (p>0.05). Statistically significant accurate measurements were verified in the pre-flared canals, except for the Novapex using a #20 K-file. CONCLUSIONS: The tested EALs showed acceptable accuracy, whereas the pre-flaring procedure revealed a more significant effect than the used file size. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572012000500008 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572012000500008 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1678-77572012000500008 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Faculdade De Odontologia De Bauru - USP |
publisher.none.fl_str_mv |
Faculdade De Odontologia De Bauru - USP |
dc.source.none.fl_str_mv |
Journal of Applied Oral Science v.20 n.5 2012 reponame:Journal of applied oral science (Online) instname:Universidade de São Paulo (USP) instacron:USP |
instname_str |
Universidade de São Paulo (USP) |
instacron_str |
USP |
institution |
USP |
reponame_str |
Journal of applied oral science (Online) |
collection |
Journal of applied oral science (Online) |
repository.name.fl_str_mv |
Journal of applied oral science (Online) - Universidade de São Paulo (USP) |
repository.mail.fl_str_mv |
||jaos@usp.br |
_version_ |
1748936437499166720 |