Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release

Detalhes bibliográficos
Autor(a) principal: Blaya, Micéli Guimarães
Data de Publicação: 2011
Outros Autores: Blaya, Diego Segatto, Mello, Paola, Flores, Érico M.M., Hirakata, Luciana Mayumi
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista odonto ciência (Online)
Texto Completo: https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/8940
Resumo: Purpose: To examine and compare the levels of several metal ions released in the saliva of patients with orthodontic appliances, at different time points before and after insertion of a miniscrew. Methods: Saliva of patients (n=20) was collected at four time points: before miniscrew placement (T1), 10 minutes (T2), 7 days (T3) and 30 days after miniscrew placement (T4). The salivary samples were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES). The release of nine different metal ions was observed: titanium (Ti), zinc (Zn), chromium (Cr), nickel (Ni), iron (Fe), copper (Cu), aluminum (Al), Vanadium (V) and cobalt (Co). Data were analyzed by descriptive statistics. Salivary metal concentrations from different time points of miniscrew treatment were compared using Wilcoxon paired tests (α=5%). Results: At time point T4, there was a quantitative increase in the salivary concentration of Cu, Ti, V, Zn, as well as a quantitative decrease in the salivary concentration of Al, Co, Cr, Fe, Ni, when compared with T1. Conclusion: It can be concluded that the placement of fixed orthodontic appliances associated with miniscrews does not lead to an increase of salivary metal ion concentrations.
id PUC_RS-22_8810073f04a96a6ede8782729bdfd386
oai_identifier_str oai:ojs.revistaseletronicas.pucrs.br:article/8940
network_acronym_str PUC_RS-22
network_name_str Revista odonto ciência (Online)
repository_id_str
spelling Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion releaseMiniimplantes de liga de titânio para ancoragem ortodôntica: um estudo in vivo de liberação de íon metálicoMetal ionsminiscrewsICP-MSICP-OESorthodontic appliancesmini-implantsÍons metálicosmini-implantesICP-MSICP-OESaparelhos ortodônticosPurpose: To examine and compare the levels of several metal ions released in the saliva of patients with orthodontic appliances, at different time points before and after insertion of a miniscrew. Methods: Saliva of patients (n=20) was collected at four time points: before miniscrew placement (T1), 10 minutes (T2), 7 days (T3) and 30 days after miniscrew placement (T4). The salivary samples were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES). The release of nine different metal ions was observed: titanium (Ti), zinc (Zn), chromium (Cr), nickel (Ni), iron (Fe), copper (Cu), aluminum (Al), Vanadium (V) and cobalt (Co). Data were analyzed by descriptive statistics. Salivary metal concentrations from different time points of miniscrew treatment were compared using Wilcoxon paired tests (α=5%). Results: At time point T4, there was a quantitative increase in the salivary concentration of Cu, Ti, V, Zn, as well as a quantitative decrease in the salivary concentration of Al, Co, Cr, Fe, Ni, when compared with T1. Conclusion: It can be concluded that the placement of fixed orthodontic appliances associated with miniscrews does not lead to an increase of salivary metal ion concentrations.Objetivo: Examinar e comparar os níveis de diferentes íons metálicos liberados na saliva de pacientes com aparelhos ortodônticos, em diferentes tempos: antes e após a inserção de mini-implantes. Metodologia: A saliva de pacientes (n=20) foi coletada em quatro tempos diferentes: antes da inserção do mini-implante (T1), 10 minutos (T2), 7 dias (T3) e 30 dias após a remoção do mini-implante (T4). As amostras de saliva foram analisadas por espectrometria de massa de plasma com acoplamento por indução (ICP-MS) e espectrometria de emissão ótica por plasma acoplado indutivamente (ICP-OES). A liberação de nove diferentes ions metálicos foi observado: titânio (Ti), zinco (Zn), cromo (Cr), níquel (Ni), ferro (Fe), cobre (Cu), alumínio (Al), vanádio(V) e cobalto (Co).Os dados foram analisados por estatística descritiva. As concentrações de íons metálicos na saliva dos diferentes tempos estudados foram comparados através do teste pareado de Wilcoxon (α=5%). Resultados: No tempo T4, houve um aumento quantitativo na concentração salivar de Cu, Ti, V, Zn, assim como um decréscimo quantitativo na concentração salivar de Al, Co, Cr, Fe, Ni, quando comparados com T1. Conclusão: Pode ser concluído que a colocação de aparelho fixo ortodôntico associado com mini-implantes não leva a um aumento significativo na concentração salivar de íons metálicos.EDIPUCRS - Editora Universitária da PUCRS2011-08-29info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articleapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/8940Revista Odonto Ciência; Vol. 26 No. 3 (2011); 209 - 214Revista Odonto Ciência; v. 26 n. 3 (2011); 209 - 2141980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/8940/6880Blaya, Micéli GuimarãesBlaya, Diego SegattoMello, PaolaFlores, Érico M.M.Hirakata, Luciana Mayumiinfo:eu-repo/semantics/openAccess2013-11-11T11:52:27Zoai:ojs.revistaseletronicas.pucrs.br:article/8940Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-11T11:52:27Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.none.fl_str_mv Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release
Miniimplantes de liga de titânio para ancoragem ortodôntica: um estudo in vivo de liberação de íon metálico
title Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release
spellingShingle Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release
Blaya, Micéli Guimarães
Metal ions
miniscrews
ICP-MS
ICP-OES
orthodontic appliances
mini-implants
Íons metálicos
mini-implantes
ICP-MS
ICP-OES
aparelhos ortodônticos
title_short Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release
title_full Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release
title_fullStr Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release
title_full_unstemmed Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release
title_sort Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release
author Blaya, Micéli Guimarães
author_facet Blaya, Micéli Guimarães
Blaya, Diego Segatto
Mello, Paola
Flores, Érico M.M.
Hirakata, Luciana Mayumi
author_role author
author2 Blaya, Diego Segatto
Mello, Paola
Flores, Érico M.M.
Hirakata, Luciana Mayumi
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Blaya, Micéli Guimarães
Blaya, Diego Segatto
Mello, Paola
Flores, Érico M.M.
Hirakata, Luciana Mayumi
dc.subject.por.fl_str_mv Metal ions
miniscrews
ICP-MS
ICP-OES
orthodontic appliances
mini-implants
Íons metálicos
mini-implantes
ICP-MS
ICP-OES
aparelhos ortodônticos
topic Metal ions
miniscrews
ICP-MS
ICP-OES
orthodontic appliances
mini-implants
Íons metálicos
mini-implantes
ICP-MS
ICP-OES
aparelhos ortodônticos
description Purpose: To examine and compare the levels of several metal ions released in the saliva of patients with orthodontic appliances, at different time points before and after insertion of a miniscrew. Methods: Saliva of patients (n=20) was collected at four time points: before miniscrew placement (T1), 10 minutes (T2), 7 days (T3) and 30 days after miniscrew placement (T4). The salivary samples were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES). The release of nine different metal ions was observed: titanium (Ti), zinc (Zn), chromium (Cr), nickel (Ni), iron (Fe), copper (Cu), aluminum (Al), Vanadium (V) and cobalt (Co). Data were analyzed by descriptive statistics. Salivary metal concentrations from different time points of miniscrew treatment were compared using Wilcoxon paired tests (α=5%). Results: At time point T4, there was a quantitative increase in the salivary concentration of Cu, Ti, V, Zn, as well as a quantitative decrease in the salivary concentration of Al, Co, Cr, Fe, Ni, when compared with T1. Conclusion: It can be concluded that the placement of fixed orthodontic appliances associated with miniscrews does not lead to an increase of salivary metal ion concentrations.
publishDate 2011
dc.date.none.fl_str_mv 2011-08-29
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Peer-reviewed Article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/8940
url https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/8940
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/8940/6880
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
dc.source.none.fl_str_mv Revista Odonto Ciência; Vol. 26 No. 3 (2011); 209 - 214
Revista Odonto Ciência; v. 26 n. 3 (2011); 209 - 214
1980-6523
0102-9460
reponame:Revista odonto ciência (Online)
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Revista odonto ciência (Online)
collection Revista odonto ciência (Online)
repository.name.fl_str_mv Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv ||odontociencia@pucrs.br
_version_ 1754820875839864832