Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista odonto ciência (Online) |
Texto Completo: | https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/8940 |
Resumo: | Purpose: To examine and compare the levels of several metal ions released in the saliva of patients with orthodontic appliances, at different time points before and after insertion of a miniscrew. Methods: Saliva of patients (n=20) was collected at four time points: before miniscrew placement (T1), 10 minutes (T2), 7 days (T3) and 30 days after miniscrew placement (T4). The salivary samples were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES). The release of nine different metal ions was observed: titanium (Ti), zinc (Zn), chromium (Cr), nickel (Ni), iron (Fe), copper (Cu), aluminum (Al), Vanadium (V) and cobalt (Co). Data were analyzed by descriptive statistics. Salivary metal concentrations from different time points of miniscrew treatment were compared using Wilcoxon paired tests (α=5%). Results: At time point T4, there was a quantitative increase in the salivary concentration of Cu, Ti, V, Zn, as well as a quantitative decrease in the salivary concentration of Al, Co, Cr, Fe, Ni, when compared with T1. Conclusion: It can be concluded that the placement of fixed orthodontic appliances associated with miniscrews does not lead to an increase of salivary metal ion concentrations. |
id |
PUC_RS-22_8810073f04a96a6ede8782729bdfd386 |
---|---|
oai_identifier_str |
oai:ojs.revistaseletronicas.pucrs.br:article/8940 |
network_acronym_str |
PUC_RS-22 |
network_name_str |
Revista odonto ciência (Online) |
repository_id_str |
|
spelling |
Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion releaseMiniimplantes de liga de titânio para ancoragem ortodôntica: um estudo in vivo de liberação de íon metálicoMetal ionsminiscrewsICP-MSICP-OESorthodontic appliancesmini-implantsÍons metálicosmini-implantesICP-MSICP-OESaparelhos ortodônticosPurpose: To examine and compare the levels of several metal ions released in the saliva of patients with orthodontic appliances, at different time points before and after insertion of a miniscrew. Methods: Saliva of patients (n=20) was collected at four time points: before miniscrew placement (T1), 10 minutes (T2), 7 days (T3) and 30 days after miniscrew placement (T4). The salivary samples were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES). The release of nine different metal ions was observed: titanium (Ti), zinc (Zn), chromium (Cr), nickel (Ni), iron (Fe), copper (Cu), aluminum (Al), Vanadium (V) and cobalt (Co). Data were analyzed by descriptive statistics. Salivary metal concentrations from different time points of miniscrew treatment were compared using Wilcoxon paired tests (α=5%). Results: At time point T4, there was a quantitative increase in the salivary concentration of Cu, Ti, V, Zn, as well as a quantitative decrease in the salivary concentration of Al, Co, Cr, Fe, Ni, when compared with T1. Conclusion: It can be concluded that the placement of fixed orthodontic appliances associated with miniscrews does not lead to an increase of salivary metal ion concentrations.Objetivo: Examinar e comparar os níveis de diferentes íons metálicos liberados na saliva de pacientes com aparelhos ortodônticos, em diferentes tempos: antes e após a inserção de mini-implantes. Metodologia: A saliva de pacientes (n=20) foi coletada em quatro tempos diferentes: antes da inserção do mini-implante (T1), 10 minutos (T2), 7 dias (T3) e 30 dias após a remoção do mini-implante (T4). As amostras de saliva foram analisadas por espectrometria de massa de plasma com acoplamento por indução (ICP-MS) e espectrometria de emissão ótica por plasma acoplado indutivamente (ICP-OES). A liberação de nove diferentes ions metálicos foi observado: titânio (Ti), zinco (Zn), cromo (Cr), níquel (Ni), ferro (Fe), cobre (Cu), alumínio (Al), vanádio(V) e cobalto (Co).Os dados foram analisados por estatística descritiva. As concentrações de íons metálicos na saliva dos diferentes tempos estudados foram comparados através do teste pareado de Wilcoxon (α=5%). Resultados: No tempo T4, houve um aumento quantitativo na concentração salivar de Cu, Ti, V, Zn, assim como um decréscimo quantitativo na concentração salivar de Al, Co, Cr, Fe, Ni, quando comparados com T1. Conclusão: Pode ser concluído que a colocação de aparelho fixo ortodôntico associado com mini-implantes não leva a um aumento significativo na concentração salivar de íons metálicos.EDIPUCRS - Editora Universitária da PUCRS2011-08-29info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articleapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/8940Revista Odonto Ciência; Vol. 26 No. 3 (2011); 209 - 214Revista Odonto Ciência; v. 26 n. 3 (2011); 209 - 2141980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/8940/6880Blaya, Micéli GuimarãesBlaya, Diego SegattoMello, PaolaFlores, Érico M.M.Hirakata, Luciana Mayumiinfo:eu-repo/semantics/openAccess2013-11-11T11:52:27Zoai:ojs.revistaseletronicas.pucrs.br:article/8940Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-11T11:52:27Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false |
dc.title.none.fl_str_mv |
Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release Miniimplantes de liga de titânio para ancoragem ortodôntica: um estudo in vivo de liberação de íon metálico |
title |
Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release |
spellingShingle |
Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release Blaya, Micéli Guimarães Metal ions miniscrews ICP-MS ICP-OES orthodontic appliances mini-implants Íons metálicos mini-implantes ICP-MS ICP-OES aparelhos ortodônticos |
title_short |
Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release |
title_full |
Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release |
title_fullStr |
Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release |
title_full_unstemmed |
Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release |
title_sort |
Titanium alloy miniscrews for orthodontic anchorage: an in vivo study of metal ion release |
author |
Blaya, Micéli Guimarães |
author_facet |
Blaya, Micéli Guimarães Blaya, Diego Segatto Mello, Paola Flores, Érico M.M. Hirakata, Luciana Mayumi |
author_role |
author |
author2 |
Blaya, Diego Segatto Mello, Paola Flores, Érico M.M. Hirakata, Luciana Mayumi |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Blaya, Micéli Guimarães Blaya, Diego Segatto Mello, Paola Flores, Érico M.M. Hirakata, Luciana Mayumi |
dc.subject.por.fl_str_mv |
Metal ions miniscrews ICP-MS ICP-OES orthodontic appliances mini-implants Íons metálicos mini-implantes ICP-MS ICP-OES aparelhos ortodônticos |
topic |
Metal ions miniscrews ICP-MS ICP-OES orthodontic appliances mini-implants Íons metálicos mini-implantes ICP-MS ICP-OES aparelhos ortodônticos |
description |
Purpose: To examine and compare the levels of several metal ions released in the saliva of patients with orthodontic appliances, at different time points before and after insertion of a miniscrew. Methods: Saliva of patients (n=20) was collected at four time points: before miniscrew placement (T1), 10 minutes (T2), 7 days (T3) and 30 days after miniscrew placement (T4). The salivary samples were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectrometry (ICP-OES). The release of nine different metal ions was observed: titanium (Ti), zinc (Zn), chromium (Cr), nickel (Ni), iron (Fe), copper (Cu), aluminum (Al), Vanadium (V) and cobalt (Co). Data were analyzed by descriptive statistics. Salivary metal concentrations from different time points of miniscrew treatment were compared using Wilcoxon paired tests (α=5%). Results: At time point T4, there was a quantitative increase in the salivary concentration of Cu, Ti, V, Zn, as well as a quantitative decrease in the salivary concentration of Al, Co, Cr, Fe, Ni, when compared with T1. Conclusion: It can be concluded that the placement of fixed orthodontic appliances associated with miniscrews does not lead to an increase of salivary metal ion concentrations. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-08-29 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Peer-reviewed Article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/8940 |
url |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/8940 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/8940/6880 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
dc.source.none.fl_str_mv |
Revista Odonto Ciência; Vol. 26 No. 3 (2011); 209 - 214 Revista Odonto Ciência; v. 26 n. 3 (2011); 209 - 214 1980-6523 0102-9460 reponame:Revista odonto ciência (Online) instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) instacron:PUC_RS |
instname_str |
Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
instacron_str |
PUC_RS |
institution |
PUC_RS |
reponame_str |
Revista odonto ciência (Online) |
collection |
Revista odonto ciência (Online) |
repository.name.fl_str_mv |
Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
repository.mail.fl_str_mv |
||odontociencia@pucrs.br |
_version_ |
1754820875839864832 |