Characterization of the nucleus, cutting edge and failure detection in NiTi instruments for endodontic retreatment

Detalhes bibliográficos
Autor(a) principal: Decurcio, Daniel de Almeida
Data de Publicação: 2018
Outros Autores: Silvaa, Julio Almeida, Barbosa, Mateus Gehrke, Chaves, Lucas Silva, Loureiro, Marco Antônio Zaiden, Estrela, Carlos
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista odonto ciência (Online)
Texto Completo: https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/30157
Resumo: OBJECTIVE: To characterize the nucleus, cutting edge and to detect defects in surfaces of nickeltitanium (NiTi) instruments for endodontic retreatment.METHODS: The selected endodontic instruments (D-RaCe, ProTaper retreatment and Mtwo retreatment) were evaluated prior to their use in 30- and 50-fold magnification in scanning electron microscopy (SEM), for linear measurements of lateral cut edge areas and of the nucleus and the ratio between these measures. After use in simulated canals, faults in the active surface were analyzed by SEM with 30 and 50 times magnification, and 200 times magnification when faults were found. The images were examined by three evaluators, whose measurements were previously calibrated. The defects analyzed were crack, blunt and barb, and data were tabulated for analysis.RESULTS: The instruments studied differed in results. The D-RaCe system instruments had the highest nucleus:edge ratio, while ProTaper retreatment instruments yielded the lowest ratio. All instruments presented some defect, with the instruments Mtwo retreatment presenting two instruments with defects.CONCLUSION: All analyzed instruments presented some type of failure after using them for removal of the filling material of simulated root canals. The D-RaCe system presented the highest edge measurements and the smallest nucleus measurements, contrary to the ProTaper retreatment system, which presented the smallest edge measurements and the largest core measurements.
id PUC_RS-22_b3edd5d75625db0b230542c526cdaac2
oai_identifier_str oai:ojs.revistaseletronicas.pucrs.br:article/30157
network_acronym_str PUC_RS-22
network_name_str Revista odonto ciência (Online)
repository_id_str
spelling Characterization of the nucleus, cutting edge and failure detection in NiTi instruments for endodontic retreatmentCaracterização do núcleo, aresta de corte e detecção de falhas em instrumentos de NiTi para retratamento endodônticoelectron scanning microscopyendodonticsretreatment.microscopia eletrônica de varreduraendodontiaretratamento.OBJECTIVE: To characterize the nucleus, cutting edge and to detect defects in surfaces of nickeltitanium (NiTi) instruments for endodontic retreatment.METHODS: The selected endodontic instruments (D-RaCe, ProTaper retreatment and Mtwo retreatment) were evaluated prior to their use in 30- and 50-fold magnification in scanning electron microscopy (SEM), for linear measurements of lateral cut edge areas and of the nucleus and the ratio between these measures. After use in simulated canals, faults in the active surface were analyzed by SEM with 30 and 50 times magnification, and 200 times magnification when faults were found. The images were examined by three evaluators, whose measurements were previously calibrated. The defects analyzed were crack, blunt and barb, and data were tabulated for analysis.RESULTS: The instruments studied differed in results. The D-RaCe system instruments had the highest nucleus:edge ratio, while ProTaper retreatment instruments yielded the lowest ratio. All instruments presented some defect, with the instruments Mtwo retreatment presenting two instruments with defects.CONCLUSION: All analyzed instruments presented some type of failure after using them for removal of the filling material of simulated root canals. The D-RaCe system presented the highest edge measurements and the smallest nucleus measurements, contrary to the ProTaper retreatment system, which presented the smallest edge measurements and the largest core measurements.OBJETIVO: Caracterizar o núcleo, aresta de corte e detectar falhas em superfícies de instrumentos de níqueltitânio (NiTi) para retratamento endodôntico.MÉTODOS: Instrumentos endodônticos (D-RaCe; ProTaper retratamento e Mtwo retratamento) foram mensurados linearmente nas áreas da aresta lateral de corte e do núcleo, além da razão entre estas medidas. Imagens em microscopia eletrônica de varredura (MEV) foram obtidas em aumento de 30 e 50 vezes. Posterior ao uso em canais simulados, estes instrumentos foram novamente analisadas frente as falhas nas superfícies ativas por MEV, em aumentos de 30 e 50 vezes, e 200 vezes. As imagens foram examinadas por três avaliadores, previamente calibrados. Os defeitos analisados incluíram: trinca, embotamento e farpa. Os dados foram tabulados para análise descritiva.RESULTADOS: Os instrumentos estudados apresentaram resultados diferentes entre si. Os instrumentos do sistema D-RaCe apresentaram maior proporção de núcleo/aresta, enquanto os instrumentos ProTaper Retratamento mostraram a menor proporção. Todos os instrumentos apresentaram algum tipo de defeito, sendo que os instrumentos Mtwo Retratamento apresentaram dois instrumentos com defeitos.CONCLUSÃO: Todos os instrumentos apresentaram algum tipo de falha após uso em desobturação de canais radiculares simulados. Os instrumentos do sistema D-RaCe apresentaram as maiores medidas de arestas e as menores medidas de núcleo, ao contrário do sistema ProTaper Retratamento que apresentou as menores medidas de arestas e as maiores medidas de núcleo.EDIPUCRS - Editora Universitária da PUCRS2018-07-25info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articleapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/3015710.15448/1980-6523.2017.4.30157Revista Odonto Ciência; Vol. 32 No. 4 (2017); 193-198Revista Odonto Ciência; v. 32 n. 4 (2017); 193-1981980-65230102-946010.15448/1980-6523.2017.4reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/30157/17011Copyright (c) 2018 Revista Odonto Ciênciainfo:eu-repo/semantics/openAccessDecurcio, Daniel de AlmeidaSilvaa, Julio AlmeidaBarbosa, Mateus GehrkeChaves, Lucas SilvaLoureiro, Marco Antônio ZaidenEstrela, Carlos2018-07-25T17:43:28Zoai:ojs.revistaseletronicas.pucrs.br:article/30157Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2018-07-25T17:43:28Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.none.fl_str_mv Characterization of the nucleus, cutting edge and failure detection in NiTi instruments for endodontic retreatment
Caracterização do núcleo, aresta de corte e detecção de falhas em instrumentos de NiTi para retratamento endodôntico
title Characterization of the nucleus, cutting edge and failure detection in NiTi instruments for endodontic retreatment
spellingShingle Characterization of the nucleus, cutting edge and failure detection in NiTi instruments for endodontic retreatment
Decurcio, Daniel de Almeida
electron scanning microscopy
endodontics
retreatment.
microscopia eletrônica de varredura
endodontia
retratamento.
title_short Characterization of the nucleus, cutting edge and failure detection in NiTi instruments for endodontic retreatment
title_full Characterization of the nucleus, cutting edge and failure detection in NiTi instruments for endodontic retreatment
title_fullStr Characterization of the nucleus, cutting edge and failure detection in NiTi instruments for endodontic retreatment
title_full_unstemmed Characterization of the nucleus, cutting edge and failure detection in NiTi instruments for endodontic retreatment
title_sort Characterization of the nucleus, cutting edge and failure detection in NiTi instruments for endodontic retreatment
author Decurcio, Daniel de Almeida
author_facet Decurcio, Daniel de Almeida
Silvaa, Julio Almeida
Barbosa, Mateus Gehrke
Chaves, Lucas Silva
Loureiro, Marco Antônio Zaiden
Estrela, Carlos
author_role author
author2 Silvaa, Julio Almeida
Barbosa, Mateus Gehrke
Chaves, Lucas Silva
Loureiro, Marco Antônio Zaiden
Estrela, Carlos
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Decurcio, Daniel de Almeida
Silvaa, Julio Almeida
Barbosa, Mateus Gehrke
Chaves, Lucas Silva
Loureiro, Marco Antônio Zaiden
Estrela, Carlos
dc.subject.por.fl_str_mv electron scanning microscopy
endodontics
retreatment.
microscopia eletrônica de varredura
endodontia
retratamento.
topic electron scanning microscopy
endodontics
retreatment.
microscopia eletrônica de varredura
endodontia
retratamento.
description OBJECTIVE: To characterize the nucleus, cutting edge and to detect defects in surfaces of nickeltitanium (NiTi) instruments for endodontic retreatment.METHODS: The selected endodontic instruments (D-RaCe, ProTaper retreatment and Mtwo retreatment) were evaluated prior to their use in 30- and 50-fold magnification in scanning electron microscopy (SEM), for linear measurements of lateral cut edge areas and of the nucleus and the ratio between these measures. After use in simulated canals, faults in the active surface were analyzed by SEM with 30 and 50 times magnification, and 200 times magnification when faults were found. The images were examined by three evaluators, whose measurements were previously calibrated. The defects analyzed were crack, blunt and barb, and data were tabulated for analysis.RESULTS: The instruments studied differed in results. The D-RaCe system instruments had the highest nucleus:edge ratio, while ProTaper retreatment instruments yielded the lowest ratio. All instruments presented some defect, with the instruments Mtwo retreatment presenting two instruments with defects.CONCLUSION: All analyzed instruments presented some type of failure after using them for removal of the filling material of simulated root canals. The D-RaCe system presented the highest edge measurements and the smallest nucleus measurements, contrary to the ProTaper retreatment system, which presented the smallest edge measurements and the largest core measurements.
publishDate 2018
dc.date.none.fl_str_mv 2018-07-25
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Peer-reviewed Article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/30157
10.15448/1980-6523.2017.4.30157
url https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/30157
identifier_str_mv 10.15448/1980-6523.2017.4.30157
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/30157/17011
dc.rights.driver.fl_str_mv Copyright (c) 2018 Revista Odonto Ciência
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2018 Revista Odonto Ciência
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
dc.source.none.fl_str_mv Revista Odonto Ciência; Vol. 32 No. 4 (2017); 193-198
Revista Odonto Ciência; v. 32 n. 4 (2017); 193-198
1980-6523
0102-9460
10.15448/1980-6523.2017.4
reponame:Revista odonto ciência (Online)
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Revista odonto ciência (Online)
collection Revista odonto ciência (Online)
repository.name.fl_str_mv Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv ||odontociencia@pucrs.br
_version_ 1754820877173653504