Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems
Autor(a) principal: | |
---|---|
Data de Publicação: | 2008 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista odonto ciência (Online) |
Texto Completo: | https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/4250 |
Resumo: | Purpose: The purpose of this study was to evaluate the flexural strength and modulus of two adhesive systems using biaxial flexural strength test. Methods: The bonding agents (Pentron Clinical Technologies) tested were: Bond 1 (B1) and NanoBond (NB). Thirteen disks (6.1 mm diameter and 0.6 mm thick) were prepared with adhesive solutions of each bonding agents using Teflon molds. The adhesive solutions within the molds were light-activated with XL 3000 curing unit (3M ESPE) for 10 s on both sides. The disks were stored for 10 days and were tested in a universal testing machine (1.27 mm/min – Instron 5844). Data were statistically analyzed by one-way ANOVA (α=0.05). Results: The mean values of fracture strength (±SD) for adhesive systems were (in MPa): B1- 89.7±7.6 e NB- 131.1±9.5. Modulus means (±SD) were (in MPa): B1- 1999.9±258.4 e NB- 2314.5±271.0. Conclusion: The filled adhesive system (NB) exhibited higher strength and flexural modulus means than the unfilled adhesive B1. Key words: Dentin-bonding agents; flexural strength; flexural modulus |
id |
PUC_RS-22_c0f66c1974875d07a7f78ee375c33a2e |
---|---|
oai_identifier_str |
oai:ojs.revistaseletronicas.pucrs.br:article/4250 |
network_acronym_str |
PUC_RS-22 |
network_name_str |
Revista odonto ciência (Online) |
repository_id_str |
|
spelling |
Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systemsAvaliação da resistência flexural biaxial e módulo de flexão de sistemas adesivosDentin-bonding agentsflexural strengthflexural modulusAdhesionPurpose: The purpose of this study was to evaluate the flexural strength and modulus of two adhesive systems using biaxial flexural strength test. Methods: The bonding agents (Pentron Clinical Technologies) tested were: Bond 1 (B1) and NanoBond (NB). Thirteen disks (6.1 mm diameter and 0.6 mm thick) were prepared with adhesive solutions of each bonding agents using Teflon molds. The adhesive solutions within the molds were light-activated with XL 3000 curing unit (3M ESPE) for 10 s on both sides. The disks were stored for 10 days and were tested in a universal testing machine (1.27 mm/min – Instron 5844). Data were statistically analyzed by one-way ANOVA (α=0.05). Results: The mean values of fracture strength (±SD) for adhesive systems were (in MPa): B1- 89.7±7.6 e NB- 131.1±9.5. Modulus means (±SD) were (in MPa): B1- 1999.9±258.4 e NB- 2314.5±271.0. Conclusion: The filled adhesive system (NB) exhibited higher strength and flexural modulus means than the unfilled adhesive B1. Key words: Dentin-bonding agents; flexural strength; flexural modulusObjetivo: O objetivo deste estudo foi avaliar a resistência flexural e o módulo de flexão de dois sistemas adesivos, através de ensaio de resistência flexural biaxial. Metodologia: Os adesivos (Pentron Clinical Technologies) estudados foram: Bond 1 (B1) e NanoBond (NB). Treze discos de cada adesivo foram preparados com dimensões aproximadas de 6,1 mm de diâmetro e 0,6 mm de espessura. Os discos de adesivos foram confeccionados utilizando-se moldes de teflon e fotopolimerizados com aparelho XL 3000 (3M ESPE). Após armazenamento por 10 dias, os discos foram testados em máquina universal de ensaio (Instron 5844), com velocidade de 1,27 mm/min. Os dados foram submetidos à análise de variância (1 fator) ao nível de significância de 0,05. Resultados: Os valores médios (±DP) de resistência flexural para os adesivos foram (em MPa): B1- 89,7±7,6 e NB- 131,1±9,5. Os valores médios de módulo flexural (±DP) foram (em MPa): B1- 1999,9±258,4 e NB- 2314,5±271,0. Conclusão: O adesivo contendo partículas de carga (NB) mostrou maiores valores de resistência flexural e módulo de flexão que o adesivo B1. Palavras-chave: Adesivos dentinários; resistência flexural; módulo flexuralEDIPUCRS - Editora Universitária da PUCRS2008-12-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articlelaboratoryapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/4250Revista Odonto Ciência; Vol. 24 No. 1 (2009); 15 - 18Revista Odonto Ciência; v. 24 n. 1 (2009); 15 - 181980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/4250/3661Liberti, Michele SantanaMettenburg, DonaldArrais, César Augusto GalvãoRueggeberg, Frederick AllenGiannini, Marceloinfo:eu-repo/semantics/openAccess2013-11-11T13:23:39Zoai:ojs.revistaseletronicas.pucrs.br:article/4250Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-11T13:23:39Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false |
dc.title.none.fl_str_mv |
Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems Avaliação da resistência flexural biaxial e módulo de flexão de sistemas adesivos |
title |
Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems |
spellingShingle |
Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems Liberti, Michele Santana Dentin-bonding agents flexural strength flexural modulus Adhesion |
title_short |
Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems |
title_full |
Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems |
title_fullStr |
Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems |
title_full_unstemmed |
Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems |
title_sort |
Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems |
author |
Liberti, Michele Santana |
author_facet |
Liberti, Michele Santana Mettenburg, Donald Arrais, César Augusto Galvão Rueggeberg, Frederick Allen Giannini, Marcelo |
author_role |
author |
author2 |
Mettenburg, Donald Arrais, César Augusto Galvão Rueggeberg, Frederick Allen Giannini, Marcelo |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Liberti, Michele Santana Mettenburg, Donald Arrais, César Augusto Galvão Rueggeberg, Frederick Allen Giannini, Marcelo |
dc.subject.por.fl_str_mv |
Dentin-bonding agents flexural strength flexural modulus Adhesion |
topic |
Dentin-bonding agents flexural strength flexural modulus Adhesion |
description |
Purpose: The purpose of this study was to evaluate the flexural strength and modulus of two adhesive systems using biaxial flexural strength test. Methods: The bonding agents (Pentron Clinical Technologies) tested were: Bond 1 (B1) and NanoBond (NB). Thirteen disks (6.1 mm diameter and 0.6 mm thick) were prepared with adhesive solutions of each bonding agents using Teflon molds. The adhesive solutions within the molds were light-activated with XL 3000 curing unit (3M ESPE) for 10 s on both sides. The disks were stored for 10 days and were tested in a universal testing machine (1.27 mm/min – Instron 5844). Data were statistically analyzed by one-way ANOVA (α=0.05). Results: The mean values of fracture strength (±SD) for adhesive systems were (in MPa): B1- 89.7±7.6 e NB- 131.1±9.5. Modulus means (±SD) were (in MPa): B1- 1999.9±258.4 e NB- 2314.5±271.0. Conclusion: The filled adhesive system (NB) exhibited higher strength and flexural modulus means than the unfilled adhesive B1. Key words: Dentin-bonding agents; flexural strength; flexural modulus |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008-12-03 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Peer-reviewed Article laboratory |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/4250 |
url |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/4250 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/4250/3661 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
publisher.none.fl_str_mv |
EDIPUCRS - Editora Universitária da PUCRS |
dc.source.none.fl_str_mv |
Revista Odonto Ciência; Vol. 24 No. 1 (2009); 15 - 18 Revista Odonto Ciência; v. 24 n. 1 (2009); 15 - 18 1980-6523 0102-9460 reponame:Revista odonto ciência (Online) instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) instacron:PUC_RS |
instname_str |
Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
instacron_str |
PUC_RS |
institution |
PUC_RS |
reponame_str |
Revista odonto ciência (Online) |
collection |
Revista odonto ciência (Online) |
repository.name.fl_str_mv |
Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
repository.mail.fl_str_mv |
||odontociencia@pucrs.br |
_version_ |
1754820874756685824 |