Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems

Detalhes bibliográficos
Autor(a) principal: Liberti, Michele Santana
Data de Publicação: 2008
Outros Autores: Mettenburg, Donald, Arrais, César Augusto Galvão, Rueggeberg, Frederick Allen, Giannini, Marcelo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista odonto ciência (Online)
Texto Completo: https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/4250
Resumo: Purpose: The purpose of this study was to evaluate the flexural strength and modulus of two adhesive systems using biaxial flexural strength test. Methods: The bonding agents (Pentron Clinical Technologies) tested were: Bond 1 (B1) and NanoBond (NB). Thirteen disks (6.1 mm diameter and 0.6 mm thick) were prepared with adhesive solutions of each bonding agents using Teflon molds. The adhesive solutions within the molds were light-activated with XL 3000 curing unit (3M ESPE) for 10 s on both sides. The disks were stored for 10 days and were tested in a universal testing machine (1.27 mm/min – Instron 5844). Data were statistically analyzed by one-way ANOVA (α=0.05). Results: The mean values of fracture strength (±SD) for adhesive systems were (in MPa): B1- 89.7±7.6 e NB- 131.1±9.5. Modulus means (±SD) were (in MPa): B1- 1999.9±258.4 e NB- 2314.5±271.0. Conclusion: The filled adhesive system (NB) exhibited higher strength and flexural modulus means than the unfilled adhesive B1. Key words: Dentin-bonding agents; flexural strength; flexural modulus
id PUC_RS-22_c0f66c1974875d07a7f78ee375c33a2e
oai_identifier_str oai:ojs.revistaseletronicas.pucrs.br:article/4250
network_acronym_str PUC_RS-22
network_name_str Revista odonto ciência (Online)
repository_id_str
spelling Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systemsAvaliação da resistência flexural biaxial e módulo de flexão de sistemas adesivosDentin-bonding agentsflexural strengthflexural modulusAdhesionPurpose: The purpose of this study was to evaluate the flexural strength and modulus of two adhesive systems using biaxial flexural strength test. Methods: The bonding agents (Pentron Clinical Technologies) tested were: Bond 1 (B1) and NanoBond (NB). Thirteen disks (6.1 mm diameter and 0.6 mm thick) were prepared with adhesive solutions of each bonding agents using Teflon molds. The adhesive solutions within the molds were light-activated with XL 3000 curing unit (3M ESPE) for 10 s on both sides. The disks were stored for 10 days and were tested in a universal testing machine (1.27 mm/min – Instron 5844). Data were statistically analyzed by one-way ANOVA (α=0.05). Results: The mean values of fracture strength (±SD) for adhesive systems were (in MPa): B1- 89.7±7.6 e NB- 131.1±9.5. Modulus means (±SD) were (in MPa): B1- 1999.9±258.4 e NB- 2314.5±271.0. Conclusion: The filled adhesive system (NB) exhibited higher strength and flexural modulus means than the unfilled adhesive B1. Key words: Dentin-bonding agents; flexural strength; flexural modulusObjetivo: O objetivo deste estudo foi avaliar a resistência flexural e o módulo de flexão de dois sistemas adesivos, através de ensaio de resistência flexural biaxial. Metodologia: Os adesivos (Pentron Clinical Technologies) estudados foram: Bond 1 (B1) e NanoBond (NB). Treze discos de cada adesivo foram preparados com dimensões aproximadas de 6,1 mm de diâmetro e 0,6 mm de espessura. Os discos de adesivos foram confeccionados utilizando-se moldes de teflon e fotopolimerizados com aparelho XL 3000 (3M ESPE). Após armazenamento por 10 dias, os discos foram testados em máquina universal de ensaio (Instron 5844), com velocidade de 1,27 mm/min. Os dados foram submetidos à análise de variância (1 fator) ao nível de significância de 0,05. Resultados: Os valores médios (±DP) de resistência flexural para os adesivos foram (em MPa): B1- 89,7±7,6 e NB- 131,1±9,5. Os valores médios de módulo flexural (±DP) foram (em MPa): B1- 1999,9±258,4 e NB- 2314,5±271,0. Conclusão: O adesivo contendo partículas de carga (NB) mostrou maiores valores de resistência flexural e módulo de flexão que o adesivo B1. Palavras-chave: Adesivos dentinários; resistência flexural; módulo flexuralEDIPUCRS - Editora Universitária da PUCRS2008-12-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articlelaboratoryapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/4250Revista Odonto Ciência; Vol. 24 No. 1 (2009); 15 - 18Revista Odonto Ciência; v. 24 n. 1 (2009); 15 - 181980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/4250/3661Liberti, Michele SantanaMettenburg, DonaldArrais, César Augusto GalvãoRueggeberg, Frederick AllenGiannini, Marceloinfo:eu-repo/semantics/openAccess2013-11-11T13:23:39Zoai:ojs.revistaseletronicas.pucrs.br:article/4250Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-11T13:23:39Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.none.fl_str_mv Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems
Avaliação da resistência flexural biaxial e módulo de flexão de sistemas adesivos
title Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems
spellingShingle Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems
Liberti, Michele Santana
Dentin-bonding agents
flexural strength
flexural modulus
Adhesion
title_short Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems
title_full Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems
title_fullStr Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems
title_full_unstemmed Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems
title_sort Evaluation of biaxial flexural strength and modulus of filled and unfilled adhesive systems
author Liberti, Michele Santana
author_facet Liberti, Michele Santana
Mettenburg, Donald
Arrais, César Augusto Galvão
Rueggeberg, Frederick Allen
Giannini, Marcelo
author_role author
author2 Mettenburg, Donald
Arrais, César Augusto Galvão
Rueggeberg, Frederick Allen
Giannini, Marcelo
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Liberti, Michele Santana
Mettenburg, Donald
Arrais, César Augusto Galvão
Rueggeberg, Frederick Allen
Giannini, Marcelo
dc.subject.por.fl_str_mv Dentin-bonding agents
flexural strength
flexural modulus
Adhesion
topic Dentin-bonding agents
flexural strength
flexural modulus
Adhesion
description Purpose: The purpose of this study was to evaluate the flexural strength and modulus of two adhesive systems using biaxial flexural strength test. Methods: The bonding agents (Pentron Clinical Technologies) tested were: Bond 1 (B1) and NanoBond (NB). Thirteen disks (6.1 mm diameter and 0.6 mm thick) were prepared with adhesive solutions of each bonding agents using Teflon molds. The adhesive solutions within the molds were light-activated with XL 3000 curing unit (3M ESPE) for 10 s on both sides. The disks were stored for 10 days and were tested in a universal testing machine (1.27 mm/min – Instron 5844). Data were statistically analyzed by one-way ANOVA (α=0.05). Results: The mean values of fracture strength (±SD) for adhesive systems were (in MPa): B1- 89.7±7.6 e NB- 131.1±9.5. Modulus means (±SD) were (in MPa): B1- 1999.9±258.4 e NB- 2314.5±271.0. Conclusion: The filled adhesive system (NB) exhibited higher strength and flexural modulus means than the unfilled adhesive B1. Key words: Dentin-bonding agents; flexural strength; flexural modulus
publishDate 2008
dc.date.none.fl_str_mv 2008-12-03
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Peer-reviewed Article
laboratory
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/4250
url https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/4250
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/4250/3661
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
dc.source.none.fl_str_mv Revista Odonto Ciência; Vol. 24 No. 1 (2009); 15 - 18
Revista Odonto Ciência; v. 24 n. 1 (2009); 15 - 18
1980-6523
0102-9460
reponame:Revista odonto ciência (Online)
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Revista odonto ciência (Online)
collection Revista odonto ciência (Online)
repository.name.fl_str_mv Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv ||odontociencia@pucrs.br
_version_ 1754820874756685824