Determination of blood pressure in newborns [Abstract in English]
Autor(a) principal: | |
---|---|
Data de Publicação: | 2007 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | por eng |
Título da fonte: | Scientia Medica (Porto Alegre. Online) |
Texto Completo: | https://revistaseletronicas.pucrs.br/scientiamedica/article/view/1665 |
Resumo: | Objective: To describe the recommendations for the determination of the blood pressure in newborn, the methods and the devices. Sources of data: Review of medical articles about blood pressure in newborn published in the last twenty years (database: Medline, PubMed) and original articles about the flush method. Summary of the findings: Several factors complicate the measures and interpretation of the blood pressure in newborns, like variable size of the upper arm, difficulty in tearful newborn and variation in the blood pressure regarding the weight and gestational age. The measure of the blood pressure should be performed preferentially in the right upper arm, with cuff size corresponding to 40% of the circumference of the upper arm and that involves 80% to 100% of the respective extremity. Nowadays, noninvasive measurements methods of the blood pressure feel well spread, especially the use of oscillometric automatic. Moreover, the antique flush method and pulse oximetry techniques have been being cited in the literature. Like more important limitation to meets itself the validation absence of the devices in neonatology, especially in the oscillometrics devices. Conclusions: Two important elements for obtainment of exact blood pressures are a calm baby and a adequate cuff size and all described methods are adequate for measurement of the blood pressure. KEY WORDS: BLOOD PRESSURE DETERMINATION/ methods; BLOOD PRESSURE DETERMINATION/instrumentation; INFANT, NEWBORN; HYPOTENSION; HYPERTENSION INFANT NEWBORN; PREMATURE. |
id |
PUC_RS-25_7e039ced329c79faf89a819ce4bb9f22 |
---|---|
oai_identifier_str |
oai:ojs.revistaseletronicas.pucrs.br:article/1665 |
network_acronym_str |
PUC_RS-25 |
network_name_str |
Scientia Medica (Porto Alegre. Online) |
repository_id_str |
|
spelling |
Determination of blood pressure in newborns [Abstract in English]Determinação da pressão arterial em recém-nascidosHipotensãoHipertensãorecém nascido de baixo pesorecém-nascido prematuro.Objective: To describe the recommendations for the determination of the blood pressure in newborn, the methods and the devices. Sources of data: Review of medical articles about blood pressure in newborn published in the last twenty years (database: Medline, PubMed) and original articles about the flush method. Summary of the findings: Several factors complicate the measures and interpretation of the blood pressure in newborns, like variable size of the upper arm, difficulty in tearful newborn and variation in the blood pressure regarding the weight and gestational age. The measure of the blood pressure should be performed preferentially in the right upper arm, with cuff size corresponding to 40% of the circumference of the upper arm and that involves 80% to 100% of the respective extremity. Nowadays, noninvasive measurements methods of the blood pressure feel well spread, especially the use of oscillometric automatic. Moreover, the antique flush method and pulse oximetry techniques have been being cited in the literature. Like more important limitation to meets itself the validation absence of the devices in neonatology, especially in the oscillometrics devices. Conclusions: Two important elements for obtainment of exact blood pressures are a calm baby and a adequate cuff size and all described methods are adequate for measurement of the blood pressure. KEY WORDS: BLOOD PRESSURE DETERMINATION/ methods; BLOOD PRESSURE DETERMINATION/instrumentation; INFANT, NEWBORN; HYPOTENSION; HYPERTENSION INFANT NEWBORN; PREMATURE.Objetivo: descrever as recomendações para a determinação da pressão arterial em recém-nascidos, os métodos e instrumentos utilizados. Fonte de dados: revisão de artigos médicos sobre pressão arterial em recém-nascidos publicados nos últimos vinte anos (base de dados: MEDLINE, PubMed) e artigos originais sobre o método do “flush”. Síntese de dados: vários fatores dificultam as medidas e interpretação da pressão arterial em neonatos, como tamanho variável do braço, dificuldade de obtenção em recém-nascidos chorosos e variação na pressão arterial quanto à idade gestacional e peso. A medida da pressão arterial deve ser realizada preferencialmente no braço direito, com a largura do manguito correspondendo a 40% da circunferência do braço e que envolva 80% a 100% da respectiva extremidade. Atualmente, os métodos de monitorização não-invasiva da pressão arterial estão bem difundidos, especialmente o uso da oscilometria automática. Além disso, o antigo método do “flush” e a técnica da oximetria de pulso têm sido citados na literatura. Como limitação mais importante encontra-se a ausência de validação dos equipamentos em neonatologia, especialmente dos monitores oscilométricos. Conclusões: dois elementos importantes para obtenção de pressões arteriais exatas são um bebê calmo e um manguito de tamanho adequado. Todos os métodos descritos são adequados para a mensuração da pressão arterial em recém-nascidos. DESCRITORES: DETERMINAÇÃO DA PRESSÃO ARTERIAL/ métodos; DETERMINAÇÃO DA PRESSÃO ARTERIAL/ instrumentos; HIPOTENSÃO; HIPERTENSÃO; RECÉM-NASCIDO; PREMATURO.Editora da PUCRS - ediPUCRS2007-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtigo de Revisãoapplication/pdfapplication/pdfhttps://revistaseletronicas.pucrs.br/scientiamedica/article/view/1665Scientia Medica; Vol. 17 No. 3 (2007); 168-170Scientia Medica; v. 17 n. 3 (2007); 168-1701980-61081806-5562reponame:Scientia Medica (Porto Alegre. Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSporenghttps://revistaseletronicas.pucrs.br/scientiamedica/article/view/1665/2148https://revistaseletronicas.pucrs.br/scientiamedica/article/view/1665/7875Ribeiro, Manoel Antonio da SilvaGarcia, Pedro Celiny RamosFiori, Renato Machadoinfo:eu-repo/semantics/openAccess2013-07-17T13:28:18Zoai:ojs.revistaseletronicas.pucrs.br:article/1665Revistahttps://revistaseletronicas.pucrs.br/scientiamedica/PUBhttps://revistaseletronicas.pucrs.br/scientiamedica/oaiscientiamedica@pucrs.br || editora.periodicos@pucrs.br1980-61081806-5562opendoar:2013-07-17T13:28:18Scientia Medica (Porto Alegre. Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false |
dc.title.none.fl_str_mv |
Determination of blood pressure in newborns [Abstract in English] Determinação da pressão arterial em recém-nascidos |
title |
Determination of blood pressure in newborns [Abstract in English] |
spellingShingle |
Determination of blood pressure in newborns [Abstract in English] Ribeiro, Manoel Antonio da Silva Hipotensão Hipertensão recém nascido de baixo peso recém-nascido prematuro. |
title_short |
Determination of blood pressure in newborns [Abstract in English] |
title_full |
Determination of blood pressure in newborns [Abstract in English] |
title_fullStr |
Determination of blood pressure in newborns [Abstract in English] |
title_full_unstemmed |
Determination of blood pressure in newborns [Abstract in English] |
title_sort |
Determination of blood pressure in newborns [Abstract in English] |
author |
Ribeiro, Manoel Antonio da Silva |
author_facet |
Ribeiro, Manoel Antonio da Silva Garcia, Pedro Celiny Ramos Fiori, Renato Machado |
author_role |
author |
author2 |
Garcia, Pedro Celiny Ramos Fiori, Renato Machado |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Ribeiro, Manoel Antonio da Silva Garcia, Pedro Celiny Ramos Fiori, Renato Machado |
dc.subject.por.fl_str_mv |
Hipotensão Hipertensão recém nascido de baixo peso recém-nascido prematuro. |
topic |
Hipotensão Hipertensão recém nascido de baixo peso recém-nascido prematuro. |
description |
Objective: To describe the recommendations for the determination of the blood pressure in newborn, the methods and the devices. Sources of data: Review of medical articles about blood pressure in newborn published in the last twenty years (database: Medline, PubMed) and original articles about the flush method. Summary of the findings: Several factors complicate the measures and interpretation of the blood pressure in newborns, like variable size of the upper arm, difficulty in tearful newborn and variation in the blood pressure regarding the weight and gestational age. The measure of the blood pressure should be performed preferentially in the right upper arm, with cuff size corresponding to 40% of the circumference of the upper arm and that involves 80% to 100% of the respective extremity. Nowadays, noninvasive measurements methods of the blood pressure feel well spread, especially the use of oscillometric automatic. Moreover, the antique flush method and pulse oximetry techniques have been being cited in the literature. Like more important limitation to meets itself the validation absence of the devices in neonatology, especially in the oscillometrics devices. Conclusions: Two important elements for obtainment of exact blood pressures are a calm baby and a adequate cuff size and all described methods are adequate for measurement of the blood pressure. KEY WORDS: BLOOD PRESSURE DETERMINATION/ methods; BLOOD PRESSURE DETERMINATION/instrumentation; INFANT, NEWBORN; HYPOTENSION; HYPERTENSION INFANT NEWBORN; PREMATURE. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Artigo de Revisão |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://revistaseletronicas.pucrs.br/scientiamedica/article/view/1665 |
url |
https://revistaseletronicas.pucrs.br/scientiamedica/article/view/1665 |
dc.language.iso.fl_str_mv |
por eng |
language |
por eng |
dc.relation.none.fl_str_mv |
https://revistaseletronicas.pucrs.br/scientiamedica/article/view/1665/2148 https://revistaseletronicas.pucrs.br/scientiamedica/article/view/1665/7875 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf application/pdf |
dc.publisher.none.fl_str_mv |
Editora da PUCRS - ediPUCRS |
publisher.none.fl_str_mv |
Editora da PUCRS - ediPUCRS |
dc.source.none.fl_str_mv |
Scientia Medica; Vol. 17 No. 3 (2007); 168-170 Scientia Medica; v. 17 n. 3 (2007); 168-170 1980-6108 1806-5562 reponame:Scientia Medica (Porto Alegre. Online) instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) instacron:PUC_RS |
instname_str |
Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
instacron_str |
PUC_RS |
institution |
PUC_RS |
reponame_str |
Scientia Medica (Porto Alegre. Online) |
collection |
Scientia Medica (Porto Alegre. Online) |
repository.name.fl_str_mv |
Scientia Medica (Porto Alegre. Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
repository.mail.fl_str_mv |
scientiamedica@pucrs.br || editora.periodicos@pucrs.br |
_version_ |
1809101748505149440 |