Resumo: Objective: To describe the recommendations for the determination of the blood pressure in newborn, the methods and the devices. Sources of data: Review of medical articles about blood pressure in newborn published in the last twenty years (database: Medline, PubMed) and original articles about the flush method. Summary of the findings: Several factors complicate the measures and interpretation of the blood pressure in newborns, like variable size of the upper arm, difficulty in tearful newborn and variation in the blood pressure regarding the weight and gestational age. The measure of the blood pressure should be performed preferentially in the right upper arm, with cuff size corresponding to 40% of the circumference of the upper arm and that involves 80% to 100% of the respective extremity. Nowadays, noninvasive measurements methods of the blood pressure feel well spread, especially the use of oscillometric automatic. Moreover, the antique flush method and pulse oximetry techniques have been being cited in the literature. Like more important limitation to meets itself the validation absence of the devices in neonatology, especially in the oscillometrics devices. Conclusions: Two important elements for obtainment of exact blood pressures are a calm baby and a adequate cuff size and all described methods are adequate for measurement of the blood pressure. KEY WORDS: BLOOD PRESSURE DETERMINATION/ methods; BLOOD PRESSURE DETERMINATION/instrumentation; INFANT, NEWBORN; HYPOTENSION; HYPERTENSION INFANT NEWBORN; PREMATURE.
id PUC_RS-25_7e039ced329c79faf89a819ce4bb9f22
oai_identifier_str oai:ojs.revistaseletronicas.pucrs.br:article/1665
network_acronym_str PUC_RS-25
network_name_str Scientia Medica (Porto Alegre. Online)
repository_id_str
spelling Determination of blood pressure in newborns [Abstract in English]Determinação da pressão arterial em recém-nascidosHipotensãoHipertensãorecém nascido de baixo pesorecém-nascido prematuro.Objective: To describe the recommendations for the determination of the blood pressure in newborn, the methods and the devices. Sources of data: Review of medical articles about blood pressure in newborn published in the last twenty years (database: Medline, PubMed) and original articles about the flush method. Summary of the findings: Several factors complicate the measures and interpretation of the blood pressure in newborns, like variable size of the upper arm, difficulty in tearful newborn and variation in the blood pressure regarding the weight and gestational age. The measure of the blood pressure should be performed preferentially in the right upper arm, with cuff size corresponding to 40% of the circumference of the upper arm and that involves 80% to 100% of the respective extremity. Nowadays, noninvasive measurements methods of the blood pressure feel well spread, especially the use of oscillometric automatic. Moreover, the antique flush method and pulse oximetry techniques have been being cited in the literature. Like more important limitation to meets itself the validation absence of the devices in neonatology, especially in the oscillometrics devices. Conclusions: Two important elements for obtainment of exact blood pressures are a calm baby and a adequate cuff size and all described methods are adequate for measurement of the blood pressure. KEY WORDS: BLOOD PRESSURE DETERMINATION/ methods; BLOOD PRESSURE DETERMINATION/instrumentation; INFANT, NEWBORN; HYPOTENSION; HYPERTENSION INFANT NEWBORN; PREMATURE.Objetivo: descrever as recomendações para a determinação da pressão arterial em recém-nascidos, os métodos e instrumentos utilizados. Fonte de dados: revisão de artigos médicos sobre pressão arterial em recém-nascidos publicados nos últimos vinte anos (base de dados: MEDLINE, PubMed) e artigos originais sobre o método do “flush”. Síntese de dados: vários fatores dificultam as medidas e interpretação da pressão arterial em neonatos, como tamanho variável do braço, dificuldade de obtenção em recém-nascidos chorosos e variação na pressão arterial quanto à idade gestacional e peso. A medida da pressão arterial deve ser realizada preferencialmente no braço direito, com a largura do manguito correspondendo a 40% da circunferência do braço e que envolva 80% a 100% da respectiva extremidade. Atualmente, os métodos de monitorização não-invasiva da pressão arterial estão bem difundidos, especialmente o uso da oscilometria automática. Além disso, o antigo método do “flush” e a técnica da oximetria de pulso têm sido citados na literatura. Como limitação mais importante encontra-se a ausência de validação dos equipamentos em neonatologia, especialmente dos monitores oscilométricos. Conclusões: dois elementos importantes para obtenção de pressões arteriais exatas são um bebê calmo e um manguito de tamanho adequado. Todos os métodos descritos são adequados para a mensuração da pressão arterial em recém-nascidos. DESCRITORES: DETERMINAÇÃO DA PRESSÃO ARTERIAL/ métodos; DETERMINAÇÃO DA PRESSÃO ARTERIAL/ instrumentos; HIPOTENSÃO; HIPERTENSÃO; RECÉM-NASCIDO; PREMATURO.Editora da PUCRS - ediPUCRS2007-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtigo de Revisãoapplication/pdfapplication/pdfhttps://revistaseletronicas.pucrs.br/scientiamedica/article/view/1665Scientia Medica; Vol. 17 No. 3 (2007); 168-170Scientia Medica; v. 17 n. 3 (2007); 168-1701980-61081806-5562reponame:Scientia Medica (Porto Alegre. Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSporenghttps://revistaseletronicas.pucrs.br/scientiamedica/article/view/1665/2148https://revistaseletronicas.pucrs.br/scientiamedica/article/view/1665/7875Ribeiro, Manoel Antonio da SilvaGarcia, Pedro Celiny RamosFiori, Renato Machadoinfo:eu-repo/semantics/openAccess2013-07-17T13:28:18Zoai:ojs.revistaseletronicas.pucrs.br:article/1665Revistahttps://revistaseletronicas.pucrs.br/scientiamedica/PUBhttps://revistaseletronicas.pucrs.br/scientiamedica/oaiscientiamedica@pucrs.br || editora.periodicos@pucrs.br1980-61081806-5562opendoar:2013-07-17T13:28:18Scientia Medica (Porto Alegre. Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.none.fl_str_mv Determination of blood pressure in newborns [Abstract in English]
Determinação da pressão arterial em recém-nascidos
title Determination of blood pressure in newborns [Abstract in English]
spellingShingle Determination of blood pressure in newborns [Abstract in English]
Ribeiro, Manoel Antonio da Silva
Hipotensão
Hipertensão
recém nascido de baixo peso
recém-nascido prematuro.
title_short Determination of blood pressure in newborns [Abstract in English]
title_full Determination of blood pressure in newborns [Abstract in English]
title_fullStr Determination of blood pressure in newborns [Abstract in English]
title_full_unstemmed Determination of blood pressure in newborns [Abstract in English]
title_sort Determination of blood pressure in newborns [Abstract in English]
author Ribeiro, Manoel Antonio da Silva
author_facet Ribeiro, Manoel Antonio da Silva
Garcia, Pedro Celiny Ramos
Fiori, Renato Machado
author_role author
author2 Garcia, Pedro Celiny Ramos
Fiori, Renato Machado
author2_role author
author
dc.contributor.author.fl_str_mv Ribeiro, Manoel Antonio da Silva
Garcia, Pedro Celiny Ramos
Fiori, Renato Machado
dc.subject.por.fl_str_mv Hipotensão
Hipertensão
recém nascido de baixo peso
recém-nascido prematuro.
topic Hipotensão
Hipertensão
recém nascido de baixo peso
recém-nascido prematuro.
description Objective: To describe the recommendations for the determination of the blood pressure in newborn, the methods and the devices. Sources of data: Review of medical articles about blood pressure in newborn published in the last twenty years (database: Medline, PubMed) and original articles about the flush method. Summary of the findings: Several factors complicate the measures and interpretation of the blood pressure in newborns, like variable size of the upper arm, difficulty in tearful newborn and variation in the blood pressure regarding the weight and gestational age. The measure of the blood pressure should be performed preferentially in the right upper arm, with cuff size corresponding to 40% of the circumference of the upper arm and that involves 80% to 100% of the respective extremity. Nowadays, noninvasive measurements methods of the blood pressure feel well spread, especially the use of oscillometric automatic. Moreover, the antique flush method and pulse oximetry techniques have been being cited in the literature. Like more important limitation to meets itself the validation absence of the devices in neonatology, especially in the oscillometrics devices. Conclusions: Two important elements for obtainment of exact blood pressures are a calm baby and a adequate cuff size and all described methods are adequate for measurement of the blood pressure. KEY WORDS: BLOOD PRESSURE DETERMINATION/ methods; BLOOD PRESSURE DETERMINATION/instrumentation; INFANT, NEWBORN; HYPOTENSION; HYPERTENSION INFANT NEWBORN; PREMATURE.
publishDate 2007
dc.date.none.fl_str_mv 2007-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Artigo de Revisão
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revistaseletronicas.pucrs.br/scientiamedica/article/view/1665
url https://revistaseletronicas.pucrs.br/scientiamedica/article/view/1665
dc.language.iso.fl_str_mv por
eng
language por
eng
dc.relation.none.fl_str_mv https://revistaseletronicas.pucrs.br/scientiamedica/article/view/1665/2148
https://revistaseletronicas.pucrs.br/scientiamedica/article/view/1665/7875
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Editora da PUCRS - ediPUCRS
publisher.none.fl_str_mv Editora da PUCRS - ediPUCRS
dc.source.none.fl_str_mv Scientia Medica; Vol. 17 No. 3 (2007); 168-170
Scientia Medica; v. 17 n. 3 (2007); 168-170
1980-6108
1806-5562
reponame:Scientia Medica (Porto Alegre. Online)
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Scientia Medica (Porto Alegre. Online)
collection Scientia Medica (Porto Alegre. Online)
repository.name.fl_str_mv Scientia Medica (Porto Alegre. Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv scientiamedica@pucrs.br || editora.periodicos@pucrs.br
_version_ 1809101748505149440