Verificação de características eletroacústicas: estudo comparativo entre softwares de fabricantes de aparelhos de amplificação sonora individual

Detalhes bibliográficos
Autor(a) principal: Rezende, Juliana Sanches
Data de Publicação: 2009
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da PUC_SP
Texto Completo: https://tede2.pucsp.br/handle/handle/12238
Resumo: Introduction: The national hearing health policy in Brazil has made hearing aids available to hearing impaired children and adults and, therefore, the audiologist responsible for dispensing them has to deal with a number of different manufactures for different types and degrees of hearing losses. Goal: To compare the prescribed electroacustic characteristics and modifications suggested for acclimatization among software of different hearing aids manufactures. Method: Six simulated cases of sensorineural hearing losses three adults and three children, including three degrees of loss for each age, were analyzed (P45, P65 e P80). For all cases, a flat configuration was assumed. Three softwares of hearing aids brands were chosen, based on the following criteria: software NOAH 3.0 with the choice for NAL-NL1 and DSL [i/o]v4.1; availability of measurements for output at the 2cc coupler for different intensities of input signal. Procedures: - Verification of output values with the 2cc coupler when compared with the values presented for each brand software, for each hearing loss, using NAL-NL1 for adults and DSL [i/o] v.4.1 for children. Verification of output values prescribed by the original DSL[i/o] v.4.1, as compared with those prescribed by the manufacturer software considering level of acclimatization. Results: A large variation of the amplification provided by the hearing aids for children and adults was found, considering different levels of hearing loss, in most frequencies, for different input levels. This variation was between -3 and -28 dBNPS in high frequencies, comparing the DSL[i/o]v4.1 manufacturer method and the original one. Conclusion: The results of this study have revealed the verification of the electroacoustic characteristics of the hearing aids during the fitting process, ensuring the patient, especially children, a more appropriate amplification
id PUC_SP-1_8feb796685729db3842817d69b8a1ab7
oai_identifier_str oai:repositorio.pucsp.br:handle/12238
network_acronym_str PUC_SP-1
network_name_str Biblioteca Digital de Teses e Dissertações da PUC_SP
repository_id_str
spelling Novaes, Beatriz Cavalcanti de Albuquerque Caiubyhttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4249170U7Rezende, Juliana Sanches2016-04-27T18:12:41Z2009-08-122009-07-27Rezende, Juliana Sanches. Verification of hearing aid electroacoustic characteristics: Comparative study of softwares of different manufactures. 2009. 107 f. Dissertação (Mestrado em Fonoaudiologia) - Pontifícia Universidade Católica de São Paulo, São Paulo, 2009.https://tede2.pucsp.br/handle/handle/12238Introduction: The national hearing health policy in Brazil has made hearing aids available to hearing impaired children and adults and, therefore, the audiologist responsible for dispensing them has to deal with a number of different manufactures for different types and degrees of hearing losses. Goal: To compare the prescribed electroacustic characteristics and modifications suggested for acclimatization among software of different hearing aids manufactures. Method: Six simulated cases of sensorineural hearing losses three adults and three children, including three degrees of loss for each age, were analyzed (P45, P65 e P80). For all cases, a flat configuration was assumed. Three softwares of hearing aids brands were chosen, based on the following criteria: software NOAH 3.0 with the choice for NAL-NL1 and DSL [i/o]v4.1; availability of measurements for output at the 2cc coupler for different intensities of input signal. Procedures: - Verification of output values with the 2cc coupler when compared with the values presented for each brand software, for each hearing loss, using NAL-NL1 for adults and DSL [i/o] v.4.1 for children. Verification of output values prescribed by the original DSL[i/o] v.4.1, as compared with those prescribed by the manufacturer software considering level of acclimatization. Results: A large variation of the amplification provided by the hearing aids for children and adults was found, considering different levels of hearing loss, in most frequencies, for different input levels. This variation was between -3 and -28 dBNPS in high frequencies, comparing the DSL[i/o]v4.1 manufacturer method and the original one. Conclusion: The results of this study have revealed the verification of the electroacoustic characteristics of the hearing aids during the fitting process, ensuring the patient, especially children, a more appropriate amplificationIntrodução: A possibilidade de o deficiente auditivo, criança ou adulto, ter acesso a um aparelho de amplificação sonora individual (AASI) concedido por programas de Saúde Auditiva faz com que o fonoaudiólogo responsável pelo processo de seleção e indicação depare com inúmeros modelos de AASIs confeccionados por diferentes fabricantes para os diversos graus de perdas auditivas existentes. Objetivo: O objetivo desta pesquisa foi comparar a prescrição de características eletroacústicas e as modificações propostas para aclimatização feitas por softwares específicos de fabricantes de AASIs. Método: Foram simulados seis casos de perdas auditivas neurossensoriais, três em crianças e três em adultos, com diferentes graus de perda auditiva (P45, P65 e P80) e de configuração plana. Foram escolhidos três softwares de fabricantes de AASI licenciados pelo software NOAH 3.0 que tivessem como opção a escolha dos métodos prescritivos NAL-NL1 e DSL [i/o]v4.1 e a visualização no software da programação de cada fabricante do gráfico de saída, medida em acoplador de 2cc para diferentes intensidades de sons de entrada. Primeiramente, foi feita a verificação das medidas de saída dos AASIs programados no acoplador de 2cc e a comparação com os valores das medidas expressas pelos softwares dos fabricantes para cada perda auditiva prescrita pelo método NAl-NL1 para os adultos e DSL[i/o]v4.1 para crianças. Em seguida, foi feita a comparação das medidas de saída prescritas pelo software original DSL[i/o] 4.1 e as medidas prescritas pelos softwares dos fabricantes, considerando o nível de aclimatização. Resultados: Foi encontrada uma grande variação da amplificação fornecida pelos AASIs para crianças e adultos, considerando todos os graus de perdas auditivas, na maioria das frequências, para diferentes intensidades de sons de entrada. Na comparação entre o método DSL[i/o]v4.1dos fabricantes e o original, essa variação permaneceu entre -3 e -28 dBNPS nas frequências altas. Conclusão: Os resultados deste estudo evidenciaram a necessidade da verificação das características eletroacústicas dos AASIs durante o processo de seleção e indicação dos mesmos, assegurando ao paciente uma amplificação adequada, principalmente no caso de criançasCoordenação de Aperfeiçoamento de Pessoal de Nível Superiorapplication/pdfhttp://tede2.pucsp.br/tede/retrieve/25194/Juliana%20Sanches%20Rezende.pdf.jpgporPontifícia Universidade Católica de São PauloPrograma de Estudos Pós-Graduados em FonoaudiologiaPUC-SPBRFonoaudiologiaDeficiência auditivaAuxiliares de audicaoCriancas deficientes auditivasHearing aidsHearing lossChildCNPQ::CIENCIAS DA SAUDE::FONOAUDIOLOGIAVerificação de características eletroacústicas: estudo comparativo entre softwares de fabricantes de aparelhos de amplificação sonora individualVerification of hearing aid electroacoustic characteristics: Comparative study of softwares of different manufacturesinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da PUC_SPinstname:Pontifícia Universidade Católica de São Paulo (PUC-SP)instacron:PUC_SPTEXTJuliana Sanches Rezende.pdf.txtJuliana Sanches Rezende.pdf.txtExtracted texttext/plain162506https://repositorio.pucsp.br/xmlui/bitstream/handle/12238/3/Juliana%20Sanches%20Rezende.pdf.txt305ce9c33be69e251eb6bf2577302868MD53ORIGINALJuliana Sanches Rezende.pdfapplication/pdf1677085https://repositorio.pucsp.br/xmlui/bitstream/handle/12238/1/Juliana%20Sanches%20Rezende.pdf8f97a74e5513dfa77d4b0679399270e6MD51THUMBNAILJuliana Sanches Rezende.pdf.jpgJuliana Sanches Rezende.pdf.jpgGenerated Thumbnailimage/jpeg1943https://repositorio.pucsp.br/xmlui/bitstream/handle/12238/2/Juliana%20Sanches%20Rezende.pdf.jpgcc73c4c239a4c332d642ba1e7c7a9fb2MD52handle/122382022-04-27 18:48:01.216oai:repositorio.pucsp.br:handle/12238Biblioteca Digital de Teses e Dissertaçõeshttps://sapientia.pucsp.br/https://sapientia.pucsp.br/oai/requestbngkatende@pucsp.br||rapassi@pucsp.bropendoar:2022-04-27T21:48:01Biblioteca Digital de Teses e Dissertações da PUC_SP - Pontifícia Universidade Católica de São Paulo (PUC-SP)false
dc.title.por.fl_str_mv Verificação de características eletroacústicas: estudo comparativo entre softwares de fabricantes de aparelhos de amplificação sonora individual
dc.title.alternative.eng.fl_str_mv Verification of hearing aid electroacoustic characteristics: Comparative study of softwares of different manufactures
title Verificação de características eletroacústicas: estudo comparativo entre softwares de fabricantes de aparelhos de amplificação sonora individual
spellingShingle Verificação de características eletroacústicas: estudo comparativo entre softwares de fabricantes de aparelhos de amplificação sonora individual
Rezende, Juliana Sanches
Deficiência auditiva
Auxiliares de audicao
Criancas deficientes auditivas
Hearing aids
Hearing loss
Child
CNPQ::CIENCIAS DA SAUDE::FONOAUDIOLOGIA
title_short Verificação de características eletroacústicas: estudo comparativo entre softwares de fabricantes de aparelhos de amplificação sonora individual
title_full Verificação de características eletroacústicas: estudo comparativo entre softwares de fabricantes de aparelhos de amplificação sonora individual
title_fullStr Verificação de características eletroacústicas: estudo comparativo entre softwares de fabricantes de aparelhos de amplificação sonora individual
title_full_unstemmed Verificação de características eletroacústicas: estudo comparativo entre softwares de fabricantes de aparelhos de amplificação sonora individual
title_sort Verificação de características eletroacústicas: estudo comparativo entre softwares de fabricantes de aparelhos de amplificação sonora individual
author Rezende, Juliana Sanches
author_facet Rezende, Juliana Sanches
author_role author
dc.contributor.advisor1.fl_str_mv Novaes, Beatriz Cavalcanti de Albuquerque Caiuby
dc.contributor.authorLattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4249170U7
dc.contributor.author.fl_str_mv Rezende, Juliana Sanches
contributor_str_mv Novaes, Beatriz Cavalcanti de Albuquerque Caiuby
dc.subject.por.fl_str_mv Deficiência auditiva
Auxiliares de audicao
Criancas deficientes auditivas
topic Deficiência auditiva
Auxiliares de audicao
Criancas deficientes auditivas
Hearing aids
Hearing loss
Child
CNPQ::CIENCIAS DA SAUDE::FONOAUDIOLOGIA
dc.subject.eng.fl_str_mv Hearing aids
Hearing loss
Child
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS DA SAUDE::FONOAUDIOLOGIA
description Introduction: The national hearing health policy in Brazil has made hearing aids available to hearing impaired children and adults and, therefore, the audiologist responsible for dispensing them has to deal with a number of different manufactures for different types and degrees of hearing losses. Goal: To compare the prescribed electroacustic characteristics and modifications suggested for acclimatization among software of different hearing aids manufactures. Method: Six simulated cases of sensorineural hearing losses three adults and three children, including three degrees of loss for each age, were analyzed (P45, P65 e P80). For all cases, a flat configuration was assumed. Three softwares of hearing aids brands were chosen, based on the following criteria: software NOAH 3.0 with the choice for NAL-NL1 and DSL [i/o]v4.1; availability of measurements for output at the 2cc coupler for different intensities of input signal. Procedures: - Verification of output values with the 2cc coupler when compared with the values presented for each brand software, for each hearing loss, using NAL-NL1 for adults and DSL [i/o] v.4.1 for children. Verification of output values prescribed by the original DSL[i/o] v.4.1, as compared with those prescribed by the manufacturer software considering level of acclimatization. Results: A large variation of the amplification provided by the hearing aids for children and adults was found, considering different levels of hearing loss, in most frequencies, for different input levels. This variation was between -3 and -28 dBNPS in high frequencies, comparing the DSL[i/o]v4.1 manufacturer method and the original one. Conclusion: The results of this study have revealed the verification of the electroacoustic characteristics of the hearing aids during the fitting process, ensuring the patient, especially children, a more appropriate amplification
publishDate 2009
dc.date.available.fl_str_mv 2009-08-12
dc.date.issued.fl_str_mv 2009-07-27
dc.date.accessioned.fl_str_mv 2016-04-27T18:12:41Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv Rezende, Juliana Sanches. Verification of hearing aid electroacoustic characteristics: Comparative study of softwares of different manufactures. 2009. 107 f. Dissertação (Mestrado em Fonoaudiologia) - Pontifícia Universidade Católica de São Paulo, São Paulo, 2009.
dc.identifier.uri.fl_str_mv https://tede2.pucsp.br/handle/handle/12238
identifier_str_mv Rezende, Juliana Sanches. Verification of hearing aid electroacoustic characteristics: Comparative study of softwares of different manufactures. 2009. 107 f. Dissertação (Mestrado em Fonoaudiologia) - Pontifícia Universidade Católica de São Paulo, São Paulo, 2009.
url https://tede2.pucsp.br/handle/handle/12238
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Pontifícia Universidade Católica de São Paulo
dc.publisher.program.fl_str_mv Programa de Estudos Pós-Graduados em Fonoaudiologia
dc.publisher.initials.fl_str_mv PUC-SP
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Fonoaudiologia
publisher.none.fl_str_mv Pontifícia Universidade Católica de São Paulo
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da PUC_SP
instname:Pontifícia Universidade Católica de São Paulo (PUC-SP)
instacron:PUC_SP
instname_str Pontifícia Universidade Católica de São Paulo (PUC-SP)
instacron_str PUC_SP
institution PUC_SP
reponame_str Biblioteca Digital de Teses e Dissertações da PUC_SP
collection Biblioteca Digital de Teses e Dissertações da PUC_SP
bitstream.url.fl_str_mv https://repositorio.pucsp.br/xmlui/bitstream/handle/12238/3/Juliana%20Sanches%20Rezende.pdf.txt
https://repositorio.pucsp.br/xmlui/bitstream/handle/12238/1/Juliana%20Sanches%20Rezende.pdf
https://repositorio.pucsp.br/xmlui/bitstream/handle/12238/2/Juliana%20Sanches%20Rezende.pdf.jpg
bitstream.checksum.fl_str_mv 305ce9c33be69e251eb6bf2577302868
8f97a74e5513dfa77d4b0679399270e6
cc73c4c239a4c332d642ba1e7c7a9fb2
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da PUC_SP - Pontifícia Universidade Católica de São Paulo (PUC-SP)
repository.mail.fl_str_mv bngkatende@pucsp.br||rapassi@pucsp.br
_version_ 1809277912820482048