Resistência à fratura de coroas cerâmicas monolíticas fabricadas em CAD/CAM cimentadas sobre diferentes pilares de implante

Detalhes bibliográficos
Autor(a) principal: Meneghetti, Priscila Ceolin
Data de Publicação: 2019
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da PUC_RS
Texto Completo: http://tede2.pucrs.br/tede2/handle/tede/8614
Resumo: Objective: to evaluate the fracture strength of monolithic ceramic unit crowns with different thickness and cemented on solid abutment and tiBase. The hypotheses presented are that (i) the presence of the fixing screw hole decreases the crown fracture strength, (ii) the restoring material influences the fracture resistance, (iii) the restoration thickness influences the fracture resistance of the restorations. Materials and methods: A total of 64 upper second premolar crowns were made for the solid abutment and Variobase C® abutment over the implant analog Straumann Tissue Level. The crowns were made of lithium dissilicate (IPS e.max CAD) and zirconia (Incoris ZI) with 0,5 mm and 1,5 mm thickness in the occlusal, and divided into 8 groups (n = 8): SE05, SE15, SZ05, SZ15, VE05, VE15, VZ05, VZ15. The crowns were cemented with resin cement and the screw access restored with composite resin. After mechanical cycling, the specimens were submitted to the test of fracture resistance in the universal test machine and the maximum force recorded in Newtons (N). The results were submitted to the Shapiro-Wilk test followed by 3-way ANOVA and Tukey (a= 5%). Results: SZ15: 5368,6 N ± 536,74 A; SZ05: 4809,8 N ± 857,55 A; SE15: 2068,8 N ± 359,77 B; SE05: 1887,4N ± 276,94 B; VZ15: 1935,5N ± 274,51 B; VZ05: 1759,4 N ± 334,34 B; VE15: 963,5 N ± 198,92 C; VE05: 924,8 N ± 152,01 C. Conclusions: The presence of the screw access channel reduced in half the fracture strength of the crowns when compared to the crowns cemented on a solid abutment. Incoris ZI showed higher fracture resistance than the IPS e.max CAD independent of the abutment and thickness. The different thicknesses of the restorations had little influence on fracture resistance.
id P_RS_3ea7ae3718e0ad6d0d498067bd9d69d3
oai_identifier_str oai:tede2.pucrs.br:tede/8614
network_acronym_str P_RS
network_name_str Biblioteca Digital de Teses e Dissertações da PUC_RS
repository_id_str
spelling Burnett Jr., Luiz Henriquehttp://lattes.cnpq.br/1252685026530007http://lattes.cnpq.br/2752544081968434Meneghetti, Priscila Ceolin2019-05-30T14:41:10Z2019-03-14http://tede2.pucrs.br/tede2/handle/tede/8614Objective: to evaluate the fracture strength of monolithic ceramic unit crowns with different thickness and cemented on solid abutment and tiBase. The hypotheses presented are that (i) the presence of the fixing screw hole decreases the crown fracture strength, (ii) the restoring material influences the fracture resistance, (iii) the restoration thickness influences the fracture resistance of the restorations. Materials and methods: A total of 64 upper second premolar crowns were made for the solid abutment and Variobase C® abutment over the implant analog Straumann Tissue Level. The crowns were made of lithium dissilicate (IPS e.max CAD) and zirconia (Incoris ZI) with 0,5 mm and 1,5 mm thickness in the occlusal, and divided into 8 groups (n = 8): SE05, SE15, SZ05, SZ15, VE05, VE15, VZ05, VZ15. The crowns were cemented with resin cement and the screw access restored with composite resin. After mechanical cycling, the specimens were submitted to the test of fracture resistance in the universal test machine and the maximum force recorded in Newtons (N). The results were submitted to the Shapiro-Wilk test followed by 3-way ANOVA and Tukey (a= 5%). Results: SZ15: 5368,6 N ± 536,74 A; SZ05: 4809,8 N ± 857,55 A; SE15: 2068,8 N ± 359,77 B; SE05: 1887,4N ± 276,94 B; VZ15: 1935,5N ± 274,51 B; VZ05: 1759,4 N ± 334,34 B; VE15: 963,5 N ± 198,92 C; VE05: 924,8 N ± 152,01 C. Conclusions: The presence of the screw access channel reduced in half the fracture strength of the crowns when compared to the crowns cemented on a solid abutment. Incoris ZI showed higher fracture resistance than the IPS e.max CAD independent of the abutment and thickness. The different thicknesses of the restorations had little influence on fracture resistance.Objetivo: avaliar a resistência à fratura de coroas cerâmicas monolíticas com diferentes espessuras e cimentadas sobre pilar sólido e tiBase. As hipóteses apresentadas são que (i) a presença do orifício do parafuso de fixação diminui a resistência à fratura das coroas, (ii) o material restaurador influencia na resistência à fratura, (iii) a espessura da restauração influencia na resistência à fratura das restaurações. Materiais e métodos: Um total de 64 coroas de segundo pré-molar superior foram confeccionadas para os pilares Sólido e Variobase C® (tiBase) sobre o análogo do implante Straumann Tissue Level. As coroas foram confeccionadas em dissilicato de litio (IPS e.max CAD) e zircônia (Incoris ZI) com 0,5 mm e 1,5 mm de espessura na face oclusal, e divididas em 8 grupos (n=8): SE05, SE15, SZ05, SZ15, VE05, VE15, VZ05, VZ15. As coroas foram cimentadas com cimento resinoso e o acesso ao parafuso restaurado com resina composta. Após ciclagem mecânica, os corpos de prova foram submetidos ao ensaio de resistência à fratura na máquina de ensaio universal e a força máxima registrada em Newtons (N). Os resultados obtidos foram submetidos ao teste de Shapiro-Wilk seguido de ANOVA 3-way e Tukey (a= 5%). Resultados: SZ15: 5368,6 N ± 536,74 A; SZ05: 4809,8 N ± 857,55 A; SE15: 2068,8 N ± 359,77 B; SE05: 1887,4N ± 276,94 B; VZ15: 1935,5N ± 274,51 B; VZ05: 1759,4 N ± 334,34 B; VE15: 963,5 N ± 198,92 C; VE05: 924,8 N ± 152,01 C. Conclusões: A presença do canal de acesso ao parafuso reduziu pela metade a resistência à fratura das coroas quando comparados com as coroas cimentadas sobre pilar sólido. A zircônia Incoris ZI apresentou maior resistência à fratura do que o IPS e.max CAD independente do pilar e da espessura. As diferentes espessuras das restaurações tiveram pouca influência na resistência à fratura.Submitted by PPG Odontologia (odontologia-pg@pucrs.br) on 2019-04-30T17:58:30Z No. of bitstreams: 1 PRISCILA_CEOLIN MENEGHETTI_DIS.pdf: 2657075 bytes, checksum: bde96ebb49dd8c1a4fc4ca8f997d1ef1 (MD5)Approved for entry into archive by Sheila Dias (sheila.dias@pucrs.br) on 2019-05-30T14:25:52Z (GMT) No. of bitstreams: 1 PRISCILA_CEOLIN MENEGHETTI_DIS.pdf: 2657075 bytes, checksum: bde96ebb49dd8c1a4fc4ca8f997d1ef1 (MD5)Made available in DSpace on 2019-05-30T14:41:10Z (GMT). No. of bitstreams: 1 PRISCILA_CEOLIN MENEGHETTI_DIS.pdf: 2657075 bytes, checksum: bde96ebb49dd8c1a4fc4ca8f997d1ef1 (MD5) Previous issue date: 2019-03-14Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESapplication/pdfhttp://tede2.pucrs.br:80/tede2/retrieve/175212/DIS_PRISCILA_CEOLIN_MENEGHETTI_CONFIDENCIAL.pdf.jpghttps://tede2.pucrs.br/tede2/retrieve/187823/DIS_PRISCILA_CEOLIN_MENEGHETTI_COMPLETO.pdf.jpgporPontifícia Universidade Católica do Rio Grande do SulPrograma de Pós-Graduação em OdontologiaPUCRSBrasilEscola de Ciências da SaúdeCerâmica MonolíticaCAD/CAMResistência à FraturaImplante DentáriozircôniaDissilicato de LítioTiBasePilar SólidoMonolitic cCramicsCAD/CAMDental ImplantFracture StrengthIithium DissilicateKirconiaTiBaseSolid AbutmentCIENCIAS DA SAUDE::ODONTOLOGIAResistência à fratura de coroas cerâmicas monolíticas fabricadas em CAD/CAM cimentadas sobre diferentes pilares de implanteinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisTrabalho será publicado como artigo ou livro48 meses30/05/2023-7411869720500764667500500600-20704984698792443493590462550136975366info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da PUC_RSinstname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSORIGINALDIS_PRISCILA_CEOLIN_MENEGHETTI_COMPLETO.pdfDIS_PRISCILA_CEOLIN_MENEGHETTI_COMPLETO.pdfapplication/pdf2657075https://tede2.pucrs.br/tede2/bitstream/tede/8614/5/DIS_PRISCILA_CEOLIN_MENEGHETTI_COMPLETO.pdfbde96ebb49dd8c1a4fc4ca8f997d1ef1MD55THUMBNAILDIS_PRISCILA_CEOLIN_MENEGHETTI_CONFIDENCIAL.pdf.jpgDIS_PRISCILA_CEOLIN_MENEGHETTI_CONFIDENCIAL.pdf.jpgimage/jpeg4084https://tede2.pucrs.br/tede2/bitstream/tede/8614/4/DIS_PRISCILA_CEOLIN_MENEGHETTI_CONFIDENCIAL.pdf.jpg58c55d8ea300c86ec69197ab0d6510edMD54DIS_PRISCILA_CEOLIN_MENEGHETTI_COMPLETO.pdf.jpgDIS_PRISCILA_CEOLIN_MENEGHETTI_COMPLETO.pdf.jpgimage/jpeg5974https://tede2.pucrs.br/tede2/bitstream/tede/8614/7/DIS_PRISCILA_CEOLIN_MENEGHETTI_COMPLETO.pdf.jpg2cff0be84b219eedc43c7c678ca2a977MD57TEXTDIS_PRISCILA_CEOLIN_MENEGHETTI_CONFIDENCIAL.pdf.txtDIS_PRISCILA_CEOLIN_MENEGHETTI_CONFIDENCIAL.pdf.txttext/plain2303https://tede2.pucrs.br/tede2/bitstream/tede/8614/3/DIS_PRISCILA_CEOLIN_MENEGHETTI_CONFIDENCIAL.pdf.txt9b9d3d68c28a57f2b176cebe9c4b6361MD53DIS_PRISCILA_CEOLIN_MENEGHETTI_COMPLETO.pdf.txtDIS_PRISCILA_CEOLIN_MENEGHETTI_COMPLETO.pdf.txttext/plain36057https://tede2.pucrs.br/tede2/bitstream/tede/8614/6/DIS_PRISCILA_CEOLIN_MENEGHETTI_COMPLETO.pdf.txt0e4c351b280fcce6ab0517aa9d875b6bMD56LICENSElicense.txtlicense.txttext/plain; charset=utf-8590https://tede2.pucrs.br/tede2/bitstream/tede/8614/1/license.txt220e11f2d3ba5354f917c7035aadef24MD51tede/86142023-06-09 12:00:22.197oai:tede2.pucrs.br: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Biblioteca Digital de Teses e Dissertaçõeshttp://tede2.pucrs.br/tede2/PRIhttps://tede2.pucrs.br/oai/requestbiblioteca.central@pucrs.br||opendoar:2023-06-09T15:00:22Biblioteca Digital de Teses e Dissertações da PUC_RS - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.por.fl_str_mv Resistência à fratura de coroas cerâmicas monolíticas fabricadas em CAD/CAM cimentadas sobre diferentes pilares de implante
title Resistência à fratura de coroas cerâmicas monolíticas fabricadas em CAD/CAM cimentadas sobre diferentes pilares de implante
spellingShingle Resistência à fratura de coroas cerâmicas monolíticas fabricadas em CAD/CAM cimentadas sobre diferentes pilares de implante
Meneghetti, Priscila Ceolin
Cerâmica Monolítica
CAD/CAM
Resistência à Fratura
Implante Dentário
zircônia
Dissilicato de Lítio
TiBase
Pilar Sólido
Monolitic cCramics
CAD/CAM
Dental Implant
Fracture Strength
Iithium Dissilicate
Kirconia
TiBase
Solid Abutment
CIENCIAS DA SAUDE::ODONTOLOGIA
title_short Resistência à fratura de coroas cerâmicas monolíticas fabricadas em CAD/CAM cimentadas sobre diferentes pilares de implante
title_full Resistência à fratura de coroas cerâmicas monolíticas fabricadas em CAD/CAM cimentadas sobre diferentes pilares de implante
title_fullStr Resistência à fratura de coroas cerâmicas monolíticas fabricadas em CAD/CAM cimentadas sobre diferentes pilares de implante
title_full_unstemmed Resistência à fratura de coroas cerâmicas monolíticas fabricadas em CAD/CAM cimentadas sobre diferentes pilares de implante
title_sort Resistência à fratura de coroas cerâmicas monolíticas fabricadas em CAD/CAM cimentadas sobre diferentes pilares de implante
author Meneghetti, Priscila Ceolin
author_facet Meneghetti, Priscila Ceolin
author_role author
dc.contributor.advisor1.fl_str_mv Burnett Jr., Luiz Henrique
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/1252685026530007
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/2752544081968434
dc.contributor.author.fl_str_mv Meneghetti, Priscila Ceolin
contributor_str_mv Burnett Jr., Luiz Henrique
dc.subject.por.fl_str_mv Cerâmica Monolítica
CAD/CAM
Resistência à Fratura
Implante Dentário
zircônia
Dissilicato de Lítio
TiBase
Pilar Sólido
topic Cerâmica Monolítica
CAD/CAM
Resistência à Fratura
Implante Dentário
zircônia
Dissilicato de Lítio
TiBase
Pilar Sólido
Monolitic cCramics
CAD/CAM
Dental Implant
Fracture Strength
Iithium Dissilicate
Kirconia
TiBase
Solid Abutment
CIENCIAS DA SAUDE::ODONTOLOGIA
dc.subject.eng.fl_str_mv Monolitic cCramics
CAD/CAM
Dental Implant
Fracture Strength
Iithium Dissilicate
Kirconia
TiBase
Solid Abutment
dc.subject.cnpq.fl_str_mv CIENCIAS DA SAUDE::ODONTOLOGIA
description Objective: to evaluate the fracture strength of monolithic ceramic unit crowns with different thickness and cemented on solid abutment and tiBase. The hypotheses presented are that (i) the presence of the fixing screw hole decreases the crown fracture strength, (ii) the restoring material influences the fracture resistance, (iii) the restoration thickness influences the fracture resistance of the restorations. Materials and methods: A total of 64 upper second premolar crowns were made for the solid abutment and Variobase C® abutment over the implant analog Straumann Tissue Level. The crowns were made of lithium dissilicate (IPS e.max CAD) and zirconia (Incoris ZI) with 0,5 mm and 1,5 mm thickness in the occlusal, and divided into 8 groups (n = 8): SE05, SE15, SZ05, SZ15, VE05, VE15, VZ05, VZ15. The crowns were cemented with resin cement and the screw access restored with composite resin. After mechanical cycling, the specimens were submitted to the test of fracture resistance in the universal test machine and the maximum force recorded in Newtons (N). The results were submitted to the Shapiro-Wilk test followed by 3-way ANOVA and Tukey (a= 5%). Results: SZ15: 5368,6 N ± 536,74 A; SZ05: 4809,8 N ± 857,55 A; SE15: 2068,8 N ± 359,77 B; SE05: 1887,4N ± 276,94 B; VZ15: 1935,5N ± 274,51 B; VZ05: 1759,4 N ± 334,34 B; VE15: 963,5 N ± 198,92 C; VE05: 924,8 N ± 152,01 C. Conclusions: The presence of the screw access channel reduced in half the fracture strength of the crowns when compared to the crowns cemented on a solid abutment. Incoris ZI showed higher fracture resistance than the IPS e.max CAD independent of the abutment and thickness. The different thicknesses of the restorations had little influence on fracture resistance.
publishDate 2019
dc.date.accessioned.fl_str_mv 2019-05-30T14:41:10Z
dc.date.issued.fl_str_mv 2019-03-14
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://tede2.pucrs.br/tede2/handle/tede/8614
url http://tede2.pucrs.br/tede2/handle/tede/8614
dc.language.iso.fl_str_mv por
language por
dc.relation.program.fl_str_mv -7411869720500764667
dc.relation.confidence.fl_str_mv 500
500
600
dc.relation.cnpq.fl_str_mv -2070498469879244349
dc.relation.sponsorship.fl_str_mv 3590462550136975366
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Pontifícia Universidade Católica do Rio Grande do Sul
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Odontologia
dc.publisher.initials.fl_str_mv PUCRS
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Escola de Ciências da Saúde
publisher.none.fl_str_mv Pontifícia Universidade Católica do Rio Grande do Sul
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da PUC_RS
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Biblioteca Digital de Teses e Dissertações da PUC_RS
collection Biblioteca Digital de Teses e Dissertações da PUC_RS
bitstream.url.fl_str_mv https://tede2.pucrs.br/tede2/bitstream/tede/8614/5/DIS_PRISCILA_CEOLIN_MENEGHETTI_COMPLETO.pdf
https://tede2.pucrs.br/tede2/bitstream/tede/8614/4/DIS_PRISCILA_CEOLIN_MENEGHETTI_CONFIDENCIAL.pdf.jpg
https://tede2.pucrs.br/tede2/bitstream/tede/8614/7/DIS_PRISCILA_CEOLIN_MENEGHETTI_COMPLETO.pdf.jpg
https://tede2.pucrs.br/tede2/bitstream/tede/8614/3/DIS_PRISCILA_CEOLIN_MENEGHETTI_CONFIDENCIAL.pdf.txt
https://tede2.pucrs.br/tede2/bitstream/tede/8614/6/DIS_PRISCILA_CEOLIN_MENEGHETTI_COMPLETO.pdf.txt
https://tede2.pucrs.br/tede2/bitstream/tede/8614/1/license.txt
bitstream.checksum.fl_str_mv bde96ebb49dd8c1a4fc4ca8f997d1ef1
58c55d8ea300c86ec69197ab0d6510ed
2cff0be84b219eedc43c7c678ca2a977
9b9d3d68c28a57f2b176cebe9c4b6361
0e4c351b280fcce6ab0517aa9d875b6b
220e11f2d3ba5354f917c7035aadef24
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da PUC_RS - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv biblioteca.central@pucrs.br||
_version_ 1799765339289944064