Métodos de avaliação tridimensional do complexo craniofacial em tomografia cone beam

Detalhes bibliográficos
Autor(a) principal: Weissheimer, André
Data de Publicação: 2013
Tipo de documento: Tese
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da PUC_RS
Texto Completo: http://tede2.pucrs.br/tede2/handle/tede/1229
Resumo: Introduction : this thesis aimed to evaluate the software accuracy for 3D analysis of craniofacial complex in cone beam computed tomography (CBCT). With this purpose, two studies were performed. The first study evaluated the precision and accuracy of 6 imaging software programs for measuring the upper airway volume in CBCT. The second study aimed to validate a fast method for 3D superimposition of CBCT. Methods : in study 1, the sample consisted of 33 growing patients and 1 oropharynx acrylic phantom (OAP), scanned with iCAT scanner. The known OAP volume was used as gold standard (GS). Semi-automatic segmentations of the patients´ oropharynx (OP) and OAP was performed using Mimics, ITK-Snap, OsiriX, Dolphin3D, InVivo Dental and Ondemand3D software programs. In study 2, the sample consisted of CBCT scans of 18 patients. For 10 patients as a gold standard, the spatial position of the pretreatment CBCT volume was reoriented, saved as a reoriented volume, and then superimposed to the original image. For 8 patients, 4 non-growing and 4 growing patients, pre and post-treatment scans were superimposed. Superimposition accuracy was assessed by visual inspection and measured by using the CMF application and expressed via color maps. Results : in study 1, the OAP segmentations with Mimics, Dolphin3D, OsiriX and ITK-Snap showed less than 2% error in volume compared to the GS. Ondemand3D and InVivo Dental showed more than 5% error compared to the GS. In the OP segmentation, ITK-Snap, Mimics, OsiriX and Dolphin3D were statistically significantly different (P<.05) from InVivo Dental. No statistical difference (P>.05) was found between InVivo Dental and OnDemand3D. In study 2, Superimposition error of the spatial reorientation as measured by the color-coded surface distances was less than 0.5mm. Superimposition error of pre and post treatment scans for both growing and non-growing patients at the cranial base were smaller than 0.5 mm, which was considered acceptable and clinically insignificant. Conclusion : in study 1, all 6 imaging software programs were reliable but showed errors in the volume segmentation of OP. Mimics, Dolphin3D, ITK-Snap and OsiriX were similar and more accurate than InVivo Dental and Ondemand3D. In study 2, the voxel-based superimposition method evaluated was reproducible in different clinical conditions, time-efficient and potentially applicable for both research and clinical practice.
id P_RS_4b1e3eb035bc641120d8bb6ee34af4da
oai_identifier_str oai:tede2.pucrs.br:tede/1229
network_acronym_str P_RS
network_name_str Biblioteca Digital de Teses e Dissertações da PUC_RS
repository_id_str
spelling Menezes, Luciane Macedo deCPF:60644192020http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4702503Z1CPF:00500977925http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4730380J6Weissheimer, André2015-04-14T13:30:29Z2013-12-122013-03-07WEISSHEIMER, André. Métodos de avaliação tridimensional do complexo craniofacial em tomografia cone beam. 2013. 66 f. Tese (Doutorado em Odontologia) - Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, 2013.http://tede2.pucrs.br/tede2/handle/tede/1229Introduction : this thesis aimed to evaluate the software accuracy for 3D analysis of craniofacial complex in cone beam computed tomography (CBCT). With this purpose, two studies were performed. The first study evaluated the precision and accuracy of 6 imaging software programs for measuring the upper airway volume in CBCT. The second study aimed to validate a fast method for 3D superimposition of CBCT. Methods : in study 1, the sample consisted of 33 growing patients and 1 oropharynx acrylic phantom (OAP), scanned with iCAT scanner. The known OAP volume was used as gold standard (GS). Semi-automatic segmentations of the patients´ oropharynx (OP) and OAP was performed using Mimics, ITK-Snap, OsiriX, Dolphin3D, InVivo Dental and Ondemand3D software programs. In study 2, the sample consisted of CBCT scans of 18 patients. For 10 patients as a gold standard, the spatial position of the pretreatment CBCT volume was reoriented, saved as a reoriented volume, and then superimposed to the original image. For 8 patients, 4 non-growing and 4 growing patients, pre and post-treatment scans were superimposed. Superimposition accuracy was assessed by visual inspection and measured by using the CMF application and expressed via color maps. Results : in study 1, the OAP segmentations with Mimics, Dolphin3D, OsiriX and ITK-Snap showed less than 2% error in volume compared to the GS. Ondemand3D and InVivo Dental showed more than 5% error compared to the GS. In the OP segmentation, ITK-Snap, Mimics, OsiriX and Dolphin3D were statistically significantly different (P<.05) from InVivo Dental. No statistical difference (P>.05) was found between InVivo Dental and OnDemand3D. In study 2, Superimposition error of the spatial reorientation as measured by the color-coded surface distances was less than 0.5mm. Superimposition error of pre and post treatment scans for both growing and non-growing patients at the cranial base were smaller than 0.5 mm, which was considered acceptable and clinically insignificant. Conclusion : in study 1, all 6 imaging software programs were reliable but showed errors in the volume segmentation of OP. Mimics, Dolphin3D, ITK-Snap and OsiriX were similar and more accurate than InVivo Dental and Ondemand3D. In study 2, the voxel-based superimposition method evaluated was reproducible in different clinical conditions, time-efficient and potentially applicable for both research and clinical practice.Introdução : o objetivo desta tese foi avaliar a acurácia de programas para análises 3D do complexo maxilofacial em tomografia computadorizada cone beam (TCCB). Com esse propósito, dois estudos foram realizados. O primeiro estudo avaliou a precisão e acurácia de 6 programas para avaliação do volume da via aérea superior em TCCB. O segundo estudo objetivou validar um método rápido de superposição 3D de TCCB. Método : no estudo 1, a amostra consistiu de 33 pacientes e 1 Phantom de acrílico da orofaringe (PAO), escaneados com o tomógrafo iCAT. O volume conhecido do PAO foi utilizado com padrão ouro. Segmentação semiautomática da orofaringe dos pacientes (OP) e do PAO foi realizada com os programas Mimics, ITK-Snap, OsiriX, Dolphin3D, InVivo Dental e Ondemand3D. No estudo 2, a amostra consistiu de TCCB de 18 pacientes. Em 10 pacientes, como padrão de comparação, a TCCB pré-tratamento foi reorientada espacialmente, salva como TCCB reorientada, e então superposta na imagem original. Em 8 pacientes, sendo 4 sem crescimento e 4 em crescimento, foram superpostas as TCCB e pós-tratamento. A acurácia da superposição foi avaliada através de inspeção visual e mensurada através do programa CFM com mapas coloridos. Resultados : no estudo 1, as segmentações com o Mimics, Dolphin3D, OsiriX e ITK-Snap mostraram menos de 2% de erro no volume do PAO em comparação ao padrão ouro. O Ondemand3D e o InVivo Dental apresentaram mais de 5% de erro no volume do PAO em comparação ao padrão ouro. As segmentações da OP com o ITK-Snap, Mimics, OsiriX e Dolphin3D foram estatisticamente diferentes (P<.05) em comparação ao InVivo Dental. Não houve diferença estatisticamente significante (P>.05) entre os programas InVivo Dental e o OnDemand3D. No estudo 2, o erro da superposição das TCCB reorientadas, medidas através dos mapas coloridos foi menor que 0,5mm. O erro da superposição das TCCB pré-tratamento e pós-tratamento para pacientes com e sem crescimento, na região da base do crânio, foi menor que 0,5 mm e considerado aceitável e clinicamente insignificante. Conclusão : no estudo 1, todos os 6 programas foram precisos, mas apresentaram erros no volume da segmentação da OP. Mimics, Dolphin3D, ITK-Snap e OsiriX foram considerados similares e mais acurados em comparação ao InVivo Dental e Ondemand3D. No estudo 2, o método de superposição baseado em voxel avaliado foi reproduzível em diferentes condições clínicas, rápido e potencialmente aplicável para pesquisa e prática clínica.Made available in DSpace on 2015-04-14T13:30:29Z (GMT). No. of bitstreams: 1 452798.pdf: 11258762 bytes, checksum: 1779e23c337cdf8d461b246e5a82e0c5 (MD5) Previous issue date: 2013-03-07application/pdfhttp://tede2.pucrs.br:80/tede2/retrieve/8303/452798.pdf.jpgporPontifícia Universidade Católica do Rio Grande do SulPrograma de Pós-Graduação em OdontologiaPUCRSBRFaculdade de OdontologiaODONTOLOGIAORTODONTIATOMOGRAFIA COMPUTADORIZADADIAGNÓSTICO BUCALCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIAMétodos de avaliação tridimensional do complexo craniofacial em tomografia cone beaminfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesis-80965548187336651645006004673435736271820140info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da PUC_RSinstname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSTHUMBNAIL452798.pdf.jpg452798.pdf.jpgimage/jpeg3354http://tede2.pucrs.br/tede2/bitstream/tede/1229/3/452798.pdf.jpgb1a469b8ff0ae44e9ab56b6cac8b6404MD53TEXT452798.pdf.txt452798.pdf.txttext/plain76620http://tede2.pucrs.br/tede2/bitstream/tede/1229/2/452798.pdf.txtede02e20986b08bfbc9355340918f5caMD52ORIGINAL452798.pdfapplication/pdf11258762http://tede2.pucrs.br/tede2/bitstream/tede/1229/1/452798.pdf1779e23c337cdf8d461b246e5a82e0c5MD51tede/12292015-04-30 08:15:31.632oai:tede2.pucrs.br:tede/1229Biblioteca Digital de Teses e Dissertaçõeshttp://tede2.pucrs.br/tede2/PRIhttps://tede2.pucrs.br/oai/requestbiblioteca.central@pucrs.br||opendoar:2015-04-30T11:15:31Biblioteca Digital de Teses e Dissertações da PUC_RS - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.por.fl_str_mv Métodos de avaliação tridimensional do complexo craniofacial em tomografia cone beam
title Métodos de avaliação tridimensional do complexo craniofacial em tomografia cone beam
spellingShingle Métodos de avaliação tridimensional do complexo craniofacial em tomografia cone beam
Weissheimer, André
ODONTOLOGIA
ORTODONTIA
TOMOGRAFIA COMPUTADORIZADA
DIAGNÓSTICO BUCAL
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
title_short Métodos de avaliação tridimensional do complexo craniofacial em tomografia cone beam
title_full Métodos de avaliação tridimensional do complexo craniofacial em tomografia cone beam
title_fullStr Métodos de avaliação tridimensional do complexo craniofacial em tomografia cone beam
title_full_unstemmed Métodos de avaliação tridimensional do complexo craniofacial em tomografia cone beam
title_sort Métodos de avaliação tridimensional do complexo craniofacial em tomografia cone beam
author Weissheimer, André
author_facet Weissheimer, André
author_role author
dc.contributor.advisor1.fl_str_mv Menezes, Luciane Macedo de
dc.contributor.advisor1ID.fl_str_mv CPF:60644192020
dc.contributor.advisor1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4702503Z1
dc.contributor.authorID.fl_str_mv CPF:00500977925
dc.contributor.authorLattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4730380J6
dc.contributor.author.fl_str_mv Weissheimer, André
contributor_str_mv Menezes, Luciane Macedo de
dc.subject.por.fl_str_mv ODONTOLOGIA
ORTODONTIA
TOMOGRAFIA COMPUTADORIZADA
DIAGNÓSTICO BUCAL
topic ODONTOLOGIA
ORTODONTIA
TOMOGRAFIA COMPUTADORIZADA
DIAGNÓSTICO BUCAL
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
description Introduction : this thesis aimed to evaluate the software accuracy for 3D analysis of craniofacial complex in cone beam computed tomography (CBCT). With this purpose, two studies were performed. The first study evaluated the precision and accuracy of 6 imaging software programs for measuring the upper airway volume in CBCT. The second study aimed to validate a fast method for 3D superimposition of CBCT. Methods : in study 1, the sample consisted of 33 growing patients and 1 oropharynx acrylic phantom (OAP), scanned with iCAT scanner. The known OAP volume was used as gold standard (GS). Semi-automatic segmentations of the patients´ oropharynx (OP) and OAP was performed using Mimics, ITK-Snap, OsiriX, Dolphin3D, InVivo Dental and Ondemand3D software programs. In study 2, the sample consisted of CBCT scans of 18 patients. For 10 patients as a gold standard, the spatial position of the pretreatment CBCT volume was reoriented, saved as a reoriented volume, and then superimposed to the original image. For 8 patients, 4 non-growing and 4 growing patients, pre and post-treatment scans were superimposed. Superimposition accuracy was assessed by visual inspection and measured by using the CMF application and expressed via color maps. Results : in study 1, the OAP segmentations with Mimics, Dolphin3D, OsiriX and ITK-Snap showed less than 2% error in volume compared to the GS. Ondemand3D and InVivo Dental showed more than 5% error compared to the GS. In the OP segmentation, ITK-Snap, Mimics, OsiriX and Dolphin3D were statistically significantly different (P<.05) from InVivo Dental. No statistical difference (P>.05) was found between InVivo Dental and OnDemand3D. In study 2, Superimposition error of the spatial reorientation as measured by the color-coded surface distances was less than 0.5mm. Superimposition error of pre and post treatment scans for both growing and non-growing patients at the cranial base were smaller than 0.5 mm, which was considered acceptable and clinically insignificant. Conclusion : in study 1, all 6 imaging software programs were reliable but showed errors in the volume segmentation of OP. Mimics, Dolphin3D, ITK-Snap and OsiriX were similar and more accurate than InVivo Dental and Ondemand3D. In study 2, the voxel-based superimposition method evaluated was reproducible in different clinical conditions, time-efficient and potentially applicable for both research and clinical practice.
publishDate 2013
dc.date.available.fl_str_mv 2013-12-12
dc.date.issued.fl_str_mv 2013-03-07
dc.date.accessioned.fl_str_mv 2015-04-14T13:30:29Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv WEISSHEIMER, André. Métodos de avaliação tridimensional do complexo craniofacial em tomografia cone beam. 2013. 66 f. Tese (Doutorado em Odontologia) - Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, 2013.
dc.identifier.uri.fl_str_mv http://tede2.pucrs.br/tede2/handle/tede/1229
identifier_str_mv WEISSHEIMER, André. Métodos de avaliação tridimensional do complexo craniofacial em tomografia cone beam. 2013. 66 f. Tese (Doutorado em Odontologia) - Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, 2013.
url http://tede2.pucrs.br/tede2/handle/tede/1229
dc.language.iso.fl_str_mv por
language por
dc.relation.program.fl_str_mv -8096554818733665164
dc.relation.confidence.fl_str_mv 500
600
dc.relation.department.fl_str_mv 4673435736271820140
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Pontifícia Universidade Católica do Rio Grande do Sul
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Odontologia
dc.publisher.initials.fl_str_mv PUCRS
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Faculdade de Odontologia
publisher.none.fl_str_mv Pontifícia Universidade Católica do Rio Grande do Sul
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da PUC_RS
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Biblioteca Digital de Teses e Dissertações da PUC_RS
collection Biblioteca Digital de Teses e Dissertações da PUC_RS
bitstream.url.fl_str_mv http://tede2.pucrs.br/tede2/bitstream/tede/1229/3/452798.pdf.jpg
http://tede2.pucrs.br/tede2/bitstream/tede/1229/2/452798.pdf.txt
http://tede2.pucrs.br/tede2/bitstream/tede/1229/1/452798.pdf
bitstream.checksum.fl_str_mv b1a469b8ff0ae44e9ab56b6cac8b6404
ede02e20986b08bfbc9355340918f5ca
1779e23c337cdf8d461b246e5a82e0c5
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da PUC_RS - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv biblioteca.central@pucrs.br||
_version_ 1799765278281695232