Efeito da inclinação e do número de implantes em próteses totais fixas implantossuportadas : análise de elemento finito não linear com modelo tridimensional
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Tipo de documento: | Tese |
Idioma: | por |
Título da fonte: | Biblioteca Digital de Teses e Dissertações da PUC_RS |
Texto Completo: | http://tede2.pucrs.br/tede2/handle/tede/5954 |
Resumo: | The aim of this study was to evaluate the influence of the number of implants and the distal tilting of posterior implants (27 degrees) on the resulting tensions in periimplant bone, abutment screw and prosthetic screw of mandibular full-arch fixed implant supported prosthesis, using a nonlinear finite element analysis. Six virtual models were created, simulating a mandibular full-arch prosthesis with a metallic framework: models with five parallel implants (5R) and with tilted posterior implants (5I); models with four parallel implants (4R) and tilted posterior ones (4I); and models with three parallel implants (3R) and with tilted posterior implants (3I). The Von Mises tensions were analyzed, on a qualitative aspect, on the three regions of interest. The results showed that tilting the posterior implants resulted in higher tensions on the periimplant bone region.Also, the implant placed adjacent to the loading area presented the higher stress magnitudes on the three regions of interest, during all the simulations. Within the limitations of this study, it's possible to conclude that tilting the posterior implants without distalizing the implants platforms, can represent higher Von Mises tensions on the cortical periimplant bone. Still, that the use of three implants supporting a mandibular full-arch prosthesis generated higher stress values on the analyzed regions, when compared to the models simulating four and five implants. |
id |
P_RS_514c342807b47b8f63adfcc02e6f6b89 |
---|---|
oai_identifier_str |
oai:tede2.pucrs.br:tede/5954 |
network_acronym_str |
P_RS |
network_name_str |
Biblioteca Digital de Teses e Dissertações da PUC_RS |
repository_id_str |
|
spelling |
Shinkai , Rosemary Sadami Arai159.612.698-17923.056.870-87http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4730198U5Geremia , Tomás2015-04-28T14:03:32Z2014-08-28http://tede2.pucrs.br/tede2/handle/tede/5954The aim of this study was to evaluate the influence of the number of implants and the distal tilting of posterior implants (27 degrees) on the resulting tensions in periimplant bone, abutment screw and prosthetic screw of mandibular full-arch fixed implant supported prosthesis, using a nonlinear finite element analysis. Six virtual models were created, simulating a mandibular full-arch prosthesis with a metallic framework: models with five parallel implants (5R) and with tilted posterior implants (5I); models with four parallel implants (4R) and tilted posterior ones (4I); and models with three parallel implants (3R) and with tilted posterior implants (3I). The Von Mises tensions were analyzed, on a qualitative aspect, on the three regions of interest. The results showed that tilting the posterior implants resulted in higher tensions on the periimplant bone region.Also, the implant placed adjacent to the loading area presented the higher stress magnitudes on the three regions of interest, during all the simulations. Within the limitations of this study, it's possible to conclude that tilting the posterior implants without distalizing the implants platforms, can represent higher Von Mises tensions on the cortical periimplant bone. Still, that the use of three implants supporting a mandibular full-arch prosthesis generated higher stress values on the analyzed regions, when compared to the models simulating four and five implants.O objetivo do presente trabalho foi avaliar em reabilitações totais fixas implantossuportadas, através de uma Metodologia de Elementos Finitos não linear, a influência do número e da inclinação dos implantes posteriores em 27 graus para distal nas tensões em osso periimplantar cortical, parafuso do pilar protético e parafuso protético. Seis modelos virtuais foram gerados simulando uma prótese total fixa mandibular, com infraestrutura metálica: modelos com 5 implantes, paralelos entre si (5R) e com dois posteriores inclinados (5I); modelos com 4 implantes, paralelos entre si (4R) e com dois posteriores inclinados (4I); modelos com 3 implantes, paralelos entre si (3R) e com dois posteriores inclinados (3I). Uma força de 100 N foi simulada em região de primeiro molar, no cantilever protético. As tensões Von Mises resultantes foram analisadas de forma qualitativa nas três regiões de interesse.Os resultados mostraram que a utilização de implantes posteriores inclinados resultaram em maiores tensões na região periimplantar. Ainda, que o implante adjacente à carga apresentou os maiores valores de tensão nas três regiões avaliadas em todas as simulações. Dentro das limitações deste trabalho, pode-se concluir que a inclinação de implantes posteriores, sem a distalização das plataformas dos mesmos, mostra-se desfavorável no que diz respeito à incidência de tensões no osso periimplantar cortical. Além disso, a utilização de três implantes suportando uma prótese total fixa mandibular, apresentou maiores valores de tensão se comparado as situações com quatro e cinco implantes.Submitted by Setor de Tratamento da Informação - BC/PUCRS (tede2@pucrs.br) on 2015-04-28T14:03:32Z No. of bitstreams: 1 467680.pdf: 13016515 bytes, checksum: e3ef505603c7d5be9a1581e535fd60e2 (MD5)Made available in DSpace on 2015-04-28T14:03:32Z (GMT). No. of bitstreams: 1 467680.pdf: 13016515 bytes, checksum: e3ef505603c7d5be9a1581e535fd60e2 (MD5) Previous issue date: 2014-08-28application/pdfhttp://tede2.pucrs.br:80/tede2/retrieve/17820/467680.pdf.jpgporPontifícia Universidade Católica do Rio Grande do SulPrograma de Pós-Graduação em OdontologiaPUCRSBrasilFaculdade de OdontologiaODONTOLOGIAIMPLANTODONTIAPRÓTESE DENTÁRIAMANDÍBULAIMPLANTES DENTÁRIOS OSSEOINTEGRADOSOSSEOINTEGRAÇÃO (ODONTOLOGIA)CIENCIAS DA SAUDE::ODONTOLOGIAEfeito da inclinação e do número de implantes em próteses totais fixas implantossuportadas : análise de elemento finito não linear com modelo tridimensionalinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesis-80965548187336651646006006004673435736271820140-2070498469879244349info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da PUC_RSinstname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSTHUMBNAIL467680.pdf.jpg467680.pdf.jpgimage/jpeg3446http://tede2.pucrs.br/tede2/bitstream/tede/5954/4/467680.pdf.jpgeea51789fca51dcbeacbf32160d495abMD54TEXT467680.pdf.txt467680.pdf.txttext/plain146620http://tede2.pucrs.br/tede2/bitstream/tede/5954/3/467680.pdf.txt27ed5967651484c89cca2f6de20c049cMD53ORIGINAL467680.pdf467680.pdfapplication/pdf13016515http://tede2.pucrs.br/tede2/bitstream/tede/5954/2/467680.pdfe3ef505603c7d5be9a1581e535fd60e2MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-8610http://tede2.pucrs.br/tede2/bitstream/tede/5954/1/license.txt5a9d6006225b368ef605ba16b4f6d1beMD51tede/59542015-04-29 08:28:28.746oai:tede2.pucrs.br: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Biblioteca Digital de Teses e Dissertaçõeshttp://tede2.pucrs.br/tede2/PRIhttps://tede2.pucrs.br/oai/requestbiblioteca.central@pucrs.br||opendoar:2015-04-29T11:28:28Biblioteca Digital de Teses e Dissertações da PUC_RS - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false |
dc.title.por.fl_str_mv |
Efeito da inclinação e do número de implantes em próteses totais fixas implantossuportadas : análise de elemento finito não linear com modelo tridimensional |
title |
Efeito da inclinação e do número de implantes em próteses totais fixas implantossuportadas : análise de elemento finito não linear com modelo tridimensional |
spellingShingle |
Efeito da inclinação e do número de implantes em próteses totais fixas implantossuportadas : análise de elemento finito não linear com modelo tridimensional Geremia , Tomás ODONTOLOGIA IMPLANTODONTIA PRÓTESE DENTÁRIA MANDÍBULA IMPLANTES DENTÁRIOS OSSEOINTEGRADOS OSSEOINTEGRAÇÃO (ODONTOLOGIA) CIENCIAS DA SAUDE::ODONTOLOGIA |
title_short |
Efeito da inclinação e do número de implantes em próteses totais fixas implantossuportadas : análise de elemento finito não linear com modelo tridimensional |
title_full |
Efeito da inclinação e do número de implantes em próteses totais fixas implantossuportadas : análise de elemento finito não linear com modelo tridimensional |
title_fullStr |
Efeito da inclinação e do número de implantes em próteses totais fixas implantossuportadas : análise de elemento finito não linear com modelo tridimensional |
title_full_unstemmed |
Efeito da inclinação e do número de implantes em próteses totais fixas implantossuportadas : análise de elemento finito não linear com modelo tridimensional |
title_sort |
Efeito da inclinação e do número de implantes em próteses totais fixas implantossuportadas : análise de elemento finito não linear com modelo tridimensional |
author |
Geremia , Tomás |
author_facet |
Geremia , Tomás |
author_role |
author |
dc.contributor.advisor1.fl_str_mv |
Shinkai , Rosemary Sadami Arai |
dc.contributor.advisor1ID.fl_str_mv |
159.612.698-17 |
dc.contributor.authorID.fl_str_mv |
923.056.870-87 |
dc.contributor.authorLattes.fl_str_mv |
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4730198U5 |
dc.contributor.author.fl_str_mv |
Geremia , Tomás |
contributor_str_mv |
Shinkai , Rosemary Sadami Arai |
dc.subject.por.fl_str_mv |
ODONTOLOGIA IMPLANTODONTIA PRÓTESE DENTÁRIA MANDÍBULA IMPLANTES DENTÁRIOS OSSEOINTEGRADOS OSSEOINTEGRAÇÃO (ODONTOLOGIA) |
topic |
ODONTOLOGIA IMPLANTODONTIA PRÓTESE DENTÁRIA MANDÍBULA IMPLANTES DENTÁRIOS OSSEOINTEGRADOS OSSEOINTEGRAÇÃO (ODONTOLOGIA) CIENCIAS DA SAUDE::ODONTOLOGIA |
dc.subject.cnpq.fl_str_mv |
CIENCIAS DA SAUDE::ODONTOLOGIA |
description |
The aim of this study was to evaluate the influence of the number of implants and the distal tilting of posterior implants (27 degrees) on the resulting tensions in periimplant bone, abutment screw and prosthetic screw of mandibular full-arch fixed implant supported prosthesis, using a nonlinear finite element analysis. Six virtual models were created, simulating a mandibular full-arch prosthesis with a metallic framework: models with five parallel implants (5R) and with tilted posterior implants (5I); models with four parallel implants (4R) and tilted posterior ones (4I); and models with three parallel implants (3R) and with tilted posterior implants (3I). The Von Mises tensions were analyzed, on a qualitative aspect, on the three regions of interest. The results showed that tilting the posterior implants resulted in higher tensions on the periimplant bone region.Also, the implant placed adjacent to the loading area presented the higher stress magnitudes on the three regions of interest, during all the simulations. Within the limitations of this study, it's possible to conclude that tilting the posterior implants without distalizing the implants platforms, can represent higher Von Mises tensions on the cortical periimplant bone. Still, that the use of three implants supporting a mandibular full-arch prosthesis generated higher stress values on the analyzed regions, when compared to the models simulating four and five implants. |
publishDate |
2014 |
dc.date.issued.fl_str_mv |
2014-08-28 |
dc.date.accessioned.fl_str_mv |
2015-04-28T14:03:32Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/doctoralThesis |
format |
doctoralThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://tede2.pucrs.br/tede2/handle/tede/5954 |
url |
http://tede2.pucrs.br/tede2/handle/tede/5954 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.program.fl_str_mv |
-8096554818733665164 |
dc.relation.confidence.fl_str_mv |
600 600 600 |
dc.relation.department.fl_str_mv |
4673435736271820140 |
dc.relation.cnpq.fl_str_mv |
-2070498469879244349 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Pontifícia Universidade Católica do Rio Grande do Sul |
dc.publisher.program.fl_str_mv |
Programa de Pós-Graduação em Odontologia |
dc.publisher.initials.fl_str_mv |
PUCRS |
dc.publisher.country.fl_str_mv |
Brasil |
dc.publisher.department.fl_str_mv |
Faculdade de Odontologia |
publisher.none.fl_str_mv |
Pontifícia Universidade Católica do Rio Grande do Sul |
dc.source.none.fl_str_mv |
reponame:Biblioteca Digital de Teses e Dissertações da PUC_RS instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) instacron:PUC_RS |
instname_str |
Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
instacron_str |
PUC_RS |
institution |
PUC_RS |
reponame_str |
Biblioteca Digital de Teses e Dissertações da PUC_RS |
collection |
Biblioteca Digital de Teses e Dissertações da PUC_RS |
bitstream.url.fl_str_mv |
http://tede2.pucrs.br/tede2/bitstream/tede/5954/4/467680.pdf.jpg http://tede2.pucrs.br/tede2/bitstream/tede/5954/3/467680.pdf.txt http://tede2.pucrs.br/tede2/bitstream/tede/5954/2/467680.pdf http://tede2.pucrs.br/tede2/bitstream/tede/5954/1/license.txt |
bitstream.checksum.fl_str_mv |
eea51789fca51dcbeacbf32160d495ab 27ed5967651484c89cca2f6de20c049c e3ef505603c7d5be9a1581e535fd60e2 5a9d6006225b368ef605ba16b4f6d1be |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Biblioteca Digital de Teses e Dissertações da PUC_RS - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS) |
repository.mail.fl_str_mv |
biblioteca.central@pucrs.br|| |
_version_ |
1799765311704006656 |