“Medida da suavidade da mobilidade funcional por meio do comprimento do arco espectral (SPARC) e sua utilidade para a avaliação de quedas em idosos longevos”

Detalhes bibliográficos
Autor(a) principal: Figueiredo, Anelise Ineu
Data de Publicação: 2021
Tipo de documento: Tese
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da PUC_RS
Texto Completo: http://tede2.pucrs.br/tede2/handle/tede/10063
Resumo: Introduction: The aging-related neuromuscular and cognitive decline can lead to less smooth movements and motor transitions, with an impact on functional mobility. The analysis of functional mobility is important to diagnose and monitor impairments resulted from physical and cognitive declines that impact human gait. Quantitative measures of movement smoothness could be fundamental when performing the assessment of functional mobility based on the instrumented Timed Up and Go (iTUG) test. For this, we used a linear and angular spectral arc length (SPARC) analysis in the iTUG. Objective: The aim of this research was to study whether the smoothness of functional mobility assessed by the SPARC measures in the iTUG is a useful measure to detect the occurrence of falls in oldest-old. Method: This is a casecontrol study. The sample consisted of 64 oldest-old who underwent the following tests: initial anamnesis questionnaire, Mini Mental State Examination, assessment of the presence of depressive symptoms, levels of physical activity, concern about falling, confidence in balance during daily living activities, performance in static balance test and iTUG for the evaluation of the classic metrics of the test and SPARC. Results: Our results demonstrate that, in our first study (Study 1), the SPARC was able to distinguish oldest-old fallers and non-fallers during the iTUG test. Furthermore, we observed that the turning moments during the iTUG induced less smooth movements, which was more pronounced in the oldest-old fallers. In our second study (Study 2), we observed that the combination of SPARC metrics and the duration of the simple iTUG increases the ability to predict falls in oldest-old. In short, we concluded that the evaluation of SPARC metrics add value to the iTUG test and can contribute to the assessment of the tendency for the occurrence of falls in oldestold living in the community.
id P_RS_7c9f48468246007682445cfa561a1338
oai_identifier_str oai:tede2.pucrs.br:tede/10063
network_acronym_str P_RS
network_name_str Biblioteca Digital de Teses e Dissertações da PUC_RS
repository_id_str
spelling Mestriner, Regis Gemerascahttp://lattes.cnpq.br/1475439425044370http://lattes.cnpq.br/6394425408897669Figueiredo, Anelise Ineu2022-01-31T17:07:48Z2021-08-27http://tede2.pucrs.br/tede2/handle/tede/10063Introduction: The aging-related neuromuscular and cognitive decline can lead to less smooth movements and motor transitions, with an impact on functional mobility. The analysis of functional mobility is important to diagnose and monitor impairments resulted from physical and cognitive declines that impact human gait. Quantitative measures of movement smoothness could be fundamental when performing the assessment of functional mobility based on the instrumented Timed Up and Go (iTUG) test. For this, we used a linear and angular spectral arc length (SPARC) analysis in the iTUG. Objective: The aim of this research was to study whether the smoothness of functional mobility assessed by the SPARC measures in the iTUG is a useful measure to detect the occurrence of falls in oldest-old. Method: This is a casecontrol study. The sample consisted of 64 oldest-old who underwent the following tests: initial anamnesis questionnaire, Mini Mental State Examination, assessment of the presence of depressive symptoms, levels of physical activity, concern about falling, confidence in balance during daily living activities, performance in static balance test and iTUG for the evaluation of the classic metrics of the test and SPARC. Results: Our results demonstrate that, in our first study (Study 1), the SPARC was able to distinguish oldest-old fallers and non-fallers during the iTUG test. Furthermore, we observed that the turning moments during the iTUG induced less smooth movements, which was more pronounced in the oldest-old fallers. In our second study (Study 2), we observed that the combination of SPARC metrics and the duration of the simple iTUG increases the ability to predict falls in oldest-old. In short, we concluded that the evaluation of SPARC metrics add value to the iTUG test and can contribute to the assessment of the tendency for the occurrence of falls in oldestold living in the community.Introdução: O declínio neuromuscular e cognitivo relacionado ao envelhecimento pode levar à realização de movimentos e transições motoras menos suaves, com impacto na mobilidade funcional. A análise da mobilidade funcional é importante para diagnosticar e monitorar os acometimentos que resultam dos declínios físicos e cognitivos que impactam sobre a marcha humana. Medidas quantitativas de suavidade do movimento podem ser fundamentais ao realizar a avaliação da mobilidade funcional baseada no teste Timed Up and Go instrumentado (iTUG). Para isso, utilizamos uma análise do comprimento do arco espectral linear e angular (SPARC) no iTUG. Objetivo: O objetivo desta pesquisa foi estudar se a suavidade da mobilidade funcional avaliada pelas medidas do SPARC no iTUG é uma medida útil para detectar a ocorrência de quedas ao solo em idosos longevos acima de 85 anos. Metodologia: Esta é uma pesquisa do tipo caso-controle. A amostra foi composta por 64 longevos que realizaram os seguintes testes: questionário de anamnese inicial, Mini Exame do Estado Mental, avaliação de presença de sintomas depressivos, níveis de atividade física, preocupação em sofrer quedas, confiança no equilíbrio durante as atividades de vida diária, desempenho em teste de equilíbrio estático (TAF) e iTUG, por meio de um sensor inercial, para a avaliação das métricas clássicas do teste e do SPARC. Resultados: Nossos resultados demonstram que, em nosso primeiro estudo (Estudo 1), o SPARC foi capaz de distinguir longevos caidores e não caidores durante o teste do iTUG. Além disso, observou-se que os momentos de giro durante o iTUG induziram movimentos menos suaves, o que foi mais pronunciado nos longevos caidores. Em nosso segundo estudo (Estudo 2), observamos que a combinação de métricas SPARC e a duração do iTUG simples incrementa a capacidade de predição de quedas em longevos. Em suma, conclui-se que a avaliação das métricas SPARC adicionam valor ao teste do iTUG e podem contribuir para a avaliação da propensão à ocorrência de quedas em idosos longevos vivendo na comunidade.Submitted by PPG Gerontologia Biomédica (geronbio@pucrs.br) on 2022-01-27T13:23:25Z No. of bitstreams: 1 FIGUEIREDO_ANELISE_INEU_TES.pdf: 22653402 bytes, checksum: 7bcf9137be845a0f0db59d6bc1d22290 (MD5)Approved for entry into archive by Sheila Dias (sheila.dias@pucrs.br) on 2022-01-31T16:58:47Z (GMT) No. of bitstreams: 1 FIGUEIREDO_ANELISE_INEU_TES.pdf: 22653402 bytes, checksum: 7bcf9137be845a0f0db59d6bc1d22290 (MD5)Made available in DSpace on 2022-01-31T17:07:48Z (GMT). No. of bitstreams: 1 FIGUEIREDO_ANELISE_INEU_TES.pdf: 22653402 bytes, checksum: 7bcf9137be845a0f0db59d6bc1d22290 (MD5) Previous issue date: 2021-08-27Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESapplication/pdfhttp://tede2.pucrs.br:80/tede2/retrieve/183176/TES_ANELISE_INEU_FIGUEIREDO_CONFIDENCIAL.pdf.jpghttps://tede2.pucrs.br/tede2/retrieve/186362/TES_ANELISE_INEU_FIGUEIREDO_COMPLETO.pdf.jpgporPontifícia Universidade Católica do Rio Grande do SulPrograma de Pós-Graduação em Gerontologia BiomédicaPUCRSBrasilEscola de MedicinaAcidentes por QuedasLocomoçãoIdosoCIENCIAS DA SAUDE::MEDICINA“Medida da suavidade da mobilidade funcional por meio do comprimento do arco espectral (SPARC) e sua utilidade para a avaliação de quedas em idosos longevos”info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisTrabalho será publicado como artigo ou livro12 meses31/01/20238969645070886364160500600500600-224747486637135387-9693694523087866273590462550136975366info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da PUC_RSinstname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSORIGINALTES_ANELISE_INEU_FIGUEIREDO_COMPLETO.pdfTES_ANELISE_INEU_FIGUEIREDO_COMPLETO.pdfapplication/pdf13365866https://tede2.pucrs.br/tede2/bitstream/tede/10063/5/TES_ANELISE_INEU_FIGUEIREDO_COMPLETO.pdfe2e9c83915312796fd4518256e853295MD55THUMBNAILTES_ANELISE_INEU_FIGUEIREDO_CONFIDENCIAL.pdf.jpgTES_ANELISE_INEU_FIGUEIREDO_CONFIDENCIAL.pdf.jpgimage/jpeg4103https://tede2.pucrs.br/tede2/bitstream/tede/10063/3/TES_ANELISE_INEU_FIGUEIREDO_CONFIDENCIAL.pdf.jpge91fe60562d966c59ec12f3b6333ec1dMD53TES_ANELISE_INEU_FIGUEIREDO_COMPLETO.pdf.jpgTES_ANELISE_INEU_FIGUEIREDO_COMPLETO.pdf.jpgimage/jpeg5040https://tede2.pucrs.br/tede2/bitstream/tede/10063/7/TES_ANELISE_INEU_FIGUEIREDO_COMPLETO.pdf.jpg09ee3b9ef7ac378def2504e3678d4f9bMD57TEXTTES_ANELISE_INEU_FIGUEIREDO_CONFIDENCIAL.pdf.txtTES_ANELISE_INEU_FIGUEIREDO_CONFIDENCIAL.pdf.txttext/plain2226https://tede2.pucrs.br/tede2/bitstream/tede/10063/4/TES_ANELISE_INEU_FIGUEIREDO_CONFIDENCIAL.pdf.txtb53d5159021d1fb720f32d5f7a9cccd3MD54TES_ANELISE_INEU_FIGUEIREDO_COMPLETO.pdf.txtTES_ANELISE_INEU_FIGUEIREDO_COMPLETO.pdf.txttext/plain164295https://tede2.pucrs.br/tede2/bitstream/tede/10063/6/TES_ANELISE_INEU_FIGUEIREDO_COMPLETO.pdf.txt8f1d81d6030342e4509288c2b715be88MD56LICENSElicense.txtlicense.txttext/plain; charset=utf-8590https://tede2.pucrs.br/tede2/bitstream/tede/10063/1/license.txt220e11f2d3ba5354f917c7035aadef24MD51tede/100632023-02-01 12:00:18.008oai:tede2.pucrs.br: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Biblioteca Digital de Teses e Dissertaçõeshttp://tede2.pucrs.br/tede2/PRIhttps://tede2.pucrs.br/oai/requestbiblioteca.central@pucrs.br||opendoar:2023-02-01T14:00:18Biblioteca Digital de Teses e Dissertações da PUC_RS - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.por.fl_str_mv “Medida da suavidade da mobilidade funcional por meio do comprimento do arco espectral (SPARC) e sua utilidade para a avaliação de quedas em idosos longevos”
title “Medida da suavidade da mobilidade funcional por meio do comprimento do arco espectral (SPARC) e sua utilidade para a avaliação de quedas em idosos longevos”
spellingShingle “Medida da suavidade da mobilidade funcional por meio do comprimento do arco espectral (SPARC) e sua utilidade para a avaliação de quedas em idosos longevos”
Figueiredo, Anelise Ineu
Acidentes por Quedas
Locomoção
Idoso
CIENCIAS DA SAUDE::MEDICINA
title_short “Medida da suavidade da mobilidade funcional por meio do comprimento do arco espectral (SPARC) e sua utilidade para a avaliação de quedas em idosos longevos”
title_full “Medida da suavidade da mobilidade funcional por meio do comprimento do arco espectral (SPARC) e sua utilidade para a avaliação de quedas em idosos longevos”
title_fullStr “Medida da suavidade da mobilidade funcional por meio do comprimento do arco espectral (SPARC) e sua utilidade para a avaliação de quedas em idosos longevos”
title_full_unstemmed “Medida da suavidade da mobilidade funcional por meio do comprimento do arco espectral (SPARC) e sua utilidade para a avaliação de quedas em idosos longevos”
title_sort “Medida da suavidade da mobilidade funcional por meio do comprimento do arco espectral (SPARC) e sua utilidade para a avaliação de quedas em idosos longevos”
author Figueiredo, Anelise Ineu
author_facet Figueiredo, Anelise Ineu
author_role author
dc.contributor.advisor1.fl_str_mv Mestriner, Regis Gemerasca
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/1475439425044370
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/6394425408897669
dc.contributor.author.fl_str_mv Figueiredo, Anelise Ineu
contributor_str_mv Mestriner, Regis Gemerasca
dc.subject.por.fl_str_mv Acidentes por Quedas
Locomoção
Idoso
topic Acidentes por Quedas
Locomoção
Idoso
CIENCIAS DA SAUDE::MEDICINA
dc.subject.cnpq.fl_str_mv CIENCIAS DA SAUDE::MEDICINA
description Introduction: The aging-related neuromuscular and cognitive decline can lead to less smooth movements and motor transitions, with an impact on functional mobility. The analysis of functional mobility is important to diagnose and monitor impairments resulted from physical and cognitive declines that impact human gait. Quantitative measures of movement smoothness could be fundamental when performing the assessment of functional mobility based on the instrumented Timed Up and Go (iTUG) test. For this, we used a linear and angular spectral arc length (SPARC) analysis in the iTUG. Objective: The aim of this research was to study whether the smoothness of functional mobility assessed by the SPARC measures in the iTUG is a useful measure to detect the occurrence of falls in oldest-old. Method: This is a casecontrol study. The sample consisted of 64 oldest-old who underwent the following tests: initial anamnesis questionnaire, Mini Mental State Examination, assessment of the presence of depressive symptoms, levels of physical activity, concern about falling, confidence in balance during daily living activities, performance in static balance test and iTUG for the evaluation of the classic metrics of the test and SPARC. Results: Our results demonstrate that, in our first study (Study 1), the SPARC was able to distinguish oldest-old fallers and non-fallers during the iTUG test. Furthermore, we observed that the turning moments during the iTUG induced less smooth movements, which was more pronounced in the oldest-old fallers. In our second study (Study 2), we observed that the combination of SPARC metrics and the duration of the simple iTUG increases the ability to predict falls in oldest-old. In short, we concluded that the evaluation of SPARC metrics add value to the iTUG test and can contribute to the assessment of the tendency for the occurrence of falls in oldestold living in the community.
publishDate 2021
dc.date.issued.fl_str_mv 2021-08-27
dc.date.accessioned.fl_str_mv 2022-01-31T17:07:48Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://tede2.pucrs.br/tede2/handle/tede/10063
url http://tede2.pucrs.br/tede2/handle/tede/10063
dc.language.iso.fl_str_mv por
language por
dc.relation.program.fl_str_mv 8969645070886364160
dc.relation.confidence.fl_str_mv 500
600
500
600
dc.relation.department.fl_str_mv -224747486637135387
dc.relation.cnpq.fl_str_mv -969369452308786627
dc.relation.sponsorship.fl_str_mv 3590462550136975366
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Pontifícia Universidade Católica do Rio Grande do Sul
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Gerontologia Biomédica
dc.publisher.initials.fl_str_mv PUCRS
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Escola de Medicina
publisher.none.fl_str_mv Pontifícia Universidade Católica do Rio Grande do Sul
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da PUC_RS
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Biblioteca Digital de Teses e Dissertações da PUC_RS
collection Biblioteca Digital de Teses e Dissertações da PUC_RS
bitstream.url.fl_str_mv https://tede2.pucrs.br/tede2/bitstream/tede/10063/5/TES_ANELISE_INEU_FIGUEIREDO_COMPLETO.pdf
https://tede2.pucrs.br/tede2/bitstream/tede/10063/3/TES_ANELISE_INEU_FIGUEIREDO_CONFIDENCIAL.pdf.jpg
https://tede2.pucrs.br/tede2/bitstream/tede/10063/7/TES_ANELISE_INEU_FIGUEIREDO_COMPLETO.pdf.jpg
https://tede2.pucrs.br/tede2/bitstream/tede/10063/4/TES_ANELISE_INEU_FIGUEIREDO_CONFIDENCIAL.pdf.txt
https://tede2.pucrs.br/tede2/bitstream/tede/10063/6/TES_ANELISE_INEU_FIGUEIREDO_COMPLETO.pdf.txt
https://tede2.pucrs.br/tede2/bitstream/tede/10063/1/license.txt
bitstream.checksum.fl_str_mv e2e9c83915312796fd4518256e853295
e91fe60562d966c59ec12f3b6333ec1d
09ee3b9ef7ac378def2504e3678d4f9b
b53d5159021d1fb720f32d5f7a9cccd3
8f1d81d6030342e4509288c2b715be88
220e11f2d3ba5354f917c7035aadef24
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da PUC_RS - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv biblioteca.central@pucrs.br||
_version_ 1799765353765535744