Desenvolvimento e validação de metodologias analíticas para o controle de qualidade do radiofármaco Psma - 1007 (18f) para utilização em Pet/Ct

Detalhes bibliográficos
Autor(a) principal: Werlang, Frederico Guevara
Data de Publicação: 2020
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da PUC_RS
Texto Completo: http://tede2.pucrs.br/tede2/handle/tede/9189
Resumo: Radiopharmaceuticals are indispensable to assist in the diagnosis and therapeutic management of patients affected by prostate cancer. Nuclear medicine (NM) uses these drugs in imaging tests such as positron emission tomography (PET/CT) and single photon emission computed tomography (SPECT) for responses to morphofunctional images that are possible to evaluate and quantify pathological processes in a non-invasive manner. A radiopharmaceutical of great importance in this treatment is prostatic specific membrane antigen (PSMA-1007 (18F)), which can identify tiny lesions and metastatic tumours. The radioisotope - 18F - was produced by a cyclotron and a sample of the referred radiopharmaceutical was through nucleophilic substitution. Thus, this work aimed at the validation of analytical methodologies for the radiopharmaceutical PSMA-1007 (18F), specific for use in PET / CT. The validation of analytical methodologies is a guarantee for quality control that all the analyzes are well performed. Radiochemical purity was developed and validated by high performance liquid chromatography (HPLC) with a C18 column of 150 x 4.6 mm and 3.0 µm. The residual solvents monitored are ethanol and dimethyl sulfoxide (DMSO) in a chromatographic run of approximately 22 minutes. All methodologies for microbiological control are available to perform the analyzes, with the control of the production sterilization process carried out by determining the bubble point. Stability test guarantees the stability of the product and the definition of its shelf life of ten hours, in addition to ensuring the absence of radiolysis in the filling process. The half-life and radionuclide purityassay show that the radioisotope Fluor 18 (18F) was adequately used in the production.
id P_RS_aea498efa3a645eceb84d20e12721b05
oai_identifier_str oai:tede2.pucrs.br:tede/9189
network_acronym_str P_RS
network_name_str Biblioteca Digital de Teses e Dissertações da PUC_RS
repository_id_str
spelling Moriguchi Jeckel, Cristina Mariahttp://lattes.cnpq.br/9963358358351491http://lattes.cnpq.br/9060901805750945Werlang, Frederico Guevara2020-07-29T14:50:59Z2020-03-31http://tede2.pucrs.br/tede2/handle/tede/9189Radiopharmaceuticals are indispensable to assist in the diagnosis and therapeutic management of patients affected by prostate cancer. Nuclear medicine (NM) uses these drugs in imaging tests such as positron emission tomography (PET/CT) and single photon emission computed tomography (SPECT) for responses to morphofunctional images that are possible to evaluate and quantify pathological processes in a non-invasive manner. A radiopharmaceutical of great importance in this treatment is prostatic specific membrane antigen (PSMA-1007 (18F)), which can identify tiny lesions and metastatic tumours. The radioisotope - 18F - was produced by a cyclotron and a sample of the referred radiopharmaceutical was through nucleophilic substitution. Thus, this work aimed at the validation of analytical methodologies for the radiopharmaceutical PSMA-1007 (18F), specific for use in PET / CT. The validation of analytical methodologies is a guarantee for quality control that all the analyzes are well performed. Radiochemical purity was developed and validated by high performance liquid chromatography (HPLC) with a C18 column of 150 x 4.6 mm and 3.0 µm. The residual solvents monitored are ethanol and dimethyl sulfoxide (DMSO) in a chromatographic run of approximately 22 minutes. All methodologies for microbiological control are available to perform the analyzes, with the control of the production sterilization process carried out by determining the bubble point. Stability test guarantees the stability of the product and the definition of its shelf life of ten hours, in addition to ensuring the absence of radiolysis in the filling process. The half-life and radionuclide purityassay show that the radioisotope Fluor 18 (18F) was adequately used in the production.Os radiofármacos são indispensáveis para auxiliar o diagnóstico e o manejo terapêutico dos pacientes acometidos por câncer de próstata. A medicina nuclear (MN) utiliza esses medicamentos em exames de imagem como a tomografia por emissão de pósitrons (PET/CT) e a tomografia por emissão de fóton único (SPECT) para a visualização de imagens morfofuncionais capazes de avaliar e quantificar processos patológicos de maneira não invasiva. Um radiofármaco de grande importância nesse manejo terapêutico é o Prostate Specific Membrane Antigen – 1007 (18F) (PSMA-1007 (18F)) que é capaz de identificar lesões muito pequenas e tumores metastáticos. O radioisótopo – flúor-18 (18F) - foi produzido por cíclotron e a síntese do referido radiofármaco foi através de uma substituição nucleofílica. Dessa forma, esse trabalho teve como objetivo o desenvolvimento e validação de metodologias analíticas do radiofármaco PSMA-1007 (18F), específico para uso em PET/CT. A validação de metodologias analíticas é a garantia necessária para o controle de qualidade assegurar que todas as análises são adequadamente realizadas. A pureza radioquímica foi desenvolvida e validada por cromatografia líquida de alta eficiência (CLAE) com coluna C18 de 150 x 4,6 mm e 3,0 µm. Os solventes residuais monitorados são o etanol e o dimetilsulfóxido (DMSO) em corrida cromatográfica de aproximadamente 22 minutos. Todas as metodologias para o controle microbiológico estão aptas para a realização das análises, sendo o controle do processo de esterilização da produção realizado pela determinação do ponto de bolha. Um teste de estabilidade foi realizado para garantir a estabilidade do produto e a definição do seu prazo de validade de dez horas, além de garantir a ausência de radiólise no processo de envase. As análises de tempo de meia-vida e de pureza radionuclídica garantem que o radioisótopo (18F) foi adequadamente produzido.Submitted by PPG Biotecnologia Farmacêutica (mpbf@pucrs.br) on 2020-05-13T13:30:28Z No. of bitstreams: 1 Dissertação Frederico G. Werlang_FINAL_rev.pdf: 2675092 bytes, checksum: 53acdc7ff1b0c0d0aaad44b8f8f5b475 (MD5)Approved for entry into archive by Lucas Martins Kern (lucas.kern@pucrs.br) on 2020-07-29T14:41:42Z (GMT) No. of bitstreams: 1 Dissertação Frederico G. Werlang_FINAL_rev.pdf: 2675092 bytes, checksum: 53acdc7ff1b0c0d0aaad44b8f8f5b475 (MD5)Made available in DSpace on 2020-07-29T14:50:59Z (GMT). No. of bitstreams: 1 Dissertação Frederico G. Werlang_FINAL_rev.pdf: 2675092 bytes, checksum: 53acdc7ff1b0c0d0aaad44b8f8f5b475 (MD5) Previous issue date: 2020-03-31application/pdfhttp://tede2.pucrs.br:80/tede2/retrieve/178439/Disserta%c3%a7%c3%a3o%20Frederico%20G.%20Werlang_FINAL_rev.pdf.jpgporPontifícia Universidade Católica do Rio Grande do SulPrograma de Pós-Graduação em Biotecnologia FarmacêuticaPUCRSBrasilEscola de Ciências da Saúde e da VidaPSMA-1007 (18F)RadiofármacosControle de qualidadeValidaçãoCâncer de próstataDiagnóstico por imagemPET/CTPSMA-1007 (18F)RadiopharmaceuticalsQuality controlValidationProstate cancerImaging diagnosisPET / CTCIENCIAS DA SAUDE::FARMACIADesenvolvimento e validação de metodologias analíticas para o controle de qualidade do radiofármaco Psma - 1007 (18f) para utilização em Pet/Ctinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisTrabalho não apresenta restrição para publicação-66274065995604625925005006997636413449754996info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da PUC_RSinstname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSTHUMBNAILDissertação Frederico G. Werlang_FINAL_rev.pdf.jpgDissertação Frederico G. Werlang_FINAL_rev.pdf.jpgimage/jpeg6063http://tede2.pucrs.br/tede2/bitstream/tede/9189/4/Disserta%C3%A7%C3%A3o+Frederico+G.+Werlang_FINAL_rev.pdf.jpg6e9f9f62784afcca13105110c9a0af77MD54TEXTDissertação Frederico G. Werlang_FINAL_rev.pdf.txtDissertação Frederico G. Werlang_FINAL_rev.pdf.txttext/plain86124http://tede2.pucrs.br/tede2/bitstream/tede/9189/3/Disserta%C3%A7%C3%A3o+Frederico+G.+Werlang_FINAL_rev.pdf.txtdb8681a6ce712a8c3e2e40b48b90975fMD53ORIGINALDissertação Frederico G. Werlang_FINAL_rev.pdfDissertação Frederico G. Werlang_FINAL_rev.pdfapplication/pdf2675092http://tede2.pucrs.br/tede2/bitstream/tede/9189/2/Disserta%C3%A7%C3%A3o+Frederico+G.+Werlang_FINAL_rev.pdf53acdc7ff1b0c0d0aaad44b8f8f5b475MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-8590http://tede2.pucrs.br/tede2/bitstream/tede/9189/1/license.txt220e11f2d3ba5354f917c7035aadef24MD51tede/91892020-07-29 12:01:08.401oai:tede2.pucrs.br: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Biblioteca Digital de Teses e Dissertaçõeshttp://tede2.pucrs.br/tede2/PRIhttps://tede2.pucrs.br/oai/requestbiblioteca.central@pucrs.br||opendoar:2020-07-29T15:01:08Biblioteca Digital de Teses e Dissertações da PUC_RS - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.por.fl_str_mv Desenvolvimento e validação de metodologias analíticas para o controle de qualidade do radiofármaco Psma - 1007 (18f) para utilização em Pet/Ct
title Desenvolvimento e validação de metodologias analíticas para o controle de qualidade do radiofármaco Psma - 1007 (18f) para utilização em Pet/Ct
spellingShingle Desenvolvimento e validação de metodologias analíticas para o controle de qualidade do radiofármaco Psma - 1007 (18f) para utilização em Pet/Ct
Werlang, Frederico Guevara
PSMA-1007 (18F)
Radiofármacos
Controle de qualidade
Validação
Câncer de próstata
Diagnóstico por imagem
PET/CT
PSMA-1007 (18F)
Radiopharmaceuticals
Quality control
Validation
Prostate cancer
Imaging diagnosis
PET / CT
CIENCIAS DA SAUDE::FARMACIA
title_short Desenvolvimento e validação de metodologias analíticas para o controle de qualidade do radiofármaco Psma - 1007 (18f) para utilização em Pet/Ct
title_full Desenvolvimento e validação de metodologias analíticas para o controle de qualidade do radiofármaco Psma - 1007 (18f) para utilização em Pet/Ct
title_fullStr Desenvolvimento e validação de metodologias analíticas para o controle de qualidade do radiofármaco Psma - 1007 (18f) para utilização em Pet/Ct
title_full_unstemmed Desenvolvimento e validação de metodologias analíticas para o controle de qualidade do radiofármaco Psma - 1007 (18f) para utilização em Pet/Ct
title_sort Desenvolvimento e validação de metodologias analíticas para o controle de qualidade do radiofármaco Psma - 1007 (18f) para utilização em Pet/Ct
author Werlang, Frederico Guevara
author_facet Werlang, Frederico Guevara
author_role author
dc.contributor.advisor1.fl_str_mv Moriguchi Jeckel, Cristina Maria
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/9963358358351491
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/9060901805750945
dc.contributor.author.fl_str_mv Werlang, Frederico Guevara
contributor_str_mv Moriguchi Jeckel, Cristina Maria
dc.subject.por.fl_str_mv PSMA-1007 (18F)
Radiofármacos
Controle de qualidade
Validação
Câncer de próstata
Diagnóstico por imagem
PET/CT
topic PSMA-1007 (18F)
Radiofármacos
Controle de qualidade
Validação
Câncer de próstata
Diagnóstico por imagem
PET/CT
PSMA-1007 (18F)
Radiopharmaceuticals
Quality control
Validation
Prostate cancer
Imaging diagnosis
PET / CT
CIENCIAS DA SAUDE::FARMACIA
dc.subject.eng.fl_str_mv PSMA-1007 (18F)
Radiopharmaceuticals
Quality control
Validation
Prostate cancer
Imaging diagnosis
PET / CT
dc.subject.cnpq.fl_str_mv CIENCIAS DA SAUDE::FARMACIA
description Radiopharmaceuticals are indispensable to assist in the diagnosis and therapeutic management of patients affected by prostate cancer. Nuclear medicine (NM) uses these drugs in imaging tests such as positron emission tomography (PET/CT) and single photon emission computed tomography (SPECT) for responses to morphofunctional images that are possible to evaluate and quantify pathological processes in a non-invasive manner. A radiopharmaceutical of great importance in this treatment is prostatic specific membrane antigen (PSMA-1007 (18F)), which can identify tiny lesions and metastatic tumours. The radioisotope - 18F - was produced by a cyclotron and a sample of the referred radiopharmaceutical was through nucleophilic substitution. Thus, this work aimed at the validation of analytical methodologies for the radiopharmaceutical PSMA-1007 (18F), specific for use in PET / CT. The validation of analytical methodologies is a guarantee for quality control that all the analyzes are well performed. Radiochemical purity was developed and validated by high performance liquid chromatography (HPLC) with a C18 column of 150 x 4.6 mm and 3.0 µm. The residual solvents monitored are ethanol and dimethyl sulfoxide (DMSO) in a chromatographic run of approximately 22 minutes. All methodologies for microbiological control are available to perform the analyzes, with the control of the production sterilization process carried out by determining the bubble point. Stability test guarantees the stability of the product and the definition of its shelf life of ten hours, in addition to ensuring the absence of radiolysis in the filling process. The half-life and radionuclide purityassay show that the radioisotope Fluor 18 (18F) was adequately used in the production.
publishDate 2020
dc.date.accessioned.fl_str_mv 2020-07-29T14:50:59Z
dc.date.issued.fl_str_mv 2020-03-31
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://tede2.pucrs.br/tede2/handle/tede/9189
url http://tede2.pucrs.br/tede2/handle/tede/9189
dc.language.iso.fl_str_mv por
language por
dc.relation.program.fl_str_mv -6627406599560462592
dc.relation.confidence.fl_str_mv 500
500
dc.relation.cnpq.fl_str_mv 6997636413449754996
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Pontifícia Universidade Católica do Rio Grande do Sul
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Biotecnologia Farmacêutica
dc.publisher.initials.fl_str_mv PUCRS
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Escola de Ciências da Saúde e da Vida
publisher.none.fl_str_mv Pontifícia Universidade Católica do Rio Grande do Sul
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da PUC_RS
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Biblioteca Digital de Teses e Dissertações da PUC_RS
collection Biblioteca Digital de Teses e Dissertações da PUC_RS
bitstream.url.fl_str_mv http://tede2.pucrs.br/tede2/bitstream/tede/9189/4/Disserta%C3%A7%C3%A3o+Frederico+G.+Werlang_FINAL_rev.pdf.jpg
http://tede2.pucrs.br/tede2/bitstream/tede/9189/3/Disserta%C3%A7%C3%A3o+Frederico+G.+Werlang_FINAL_rev.pdf.txt
http://tede2.pucrs.br/tede2/bitstream/tede/9189/2/Disserta%C3%A7%C3%A3o+Frederico+G.+Werlang_FINAL_rev.pdf
http://tede2.pucrs.br/tede2/bitstream/tede/9189/1/license.txt
bitstream.checksum.fl_str_mv 6e9f9f62784afcca13105110c9a0af77
db8681a6ce712a8c3e2e40b48b90975f
53acdc7ff1b0c0d0aaad44b8f8f5b475
220e11f2d3ba5354f917c7035aadef24
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da PUC_RS - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv biblioteca.central@pucrs.br||
_version_ 1799765344587350016