The sensitivity of global structural parameters for unreinforced masonry buildings subjected to simulated ground motions
Autor(a) principal: | |
---|---|
Data de Publicação: | 2023 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | https://hdl.handle.net/1822/87201 |
Resumo: | This research performs a parametric study based on Equivalent Single Degree of Freedom (ESDOF) models for simplified seismic analysis of unreinforced masonry (URM) structures. This is a necessary action due to the fact that it is not affordable to model and analyze populations of masonry buildings by using detailed continuum-based models during regional seismic damage and loss estimation studies. Hence, this study focuses on the sensitivity of major structural parameters of a selected idealized hysteretic model for URM buildings. The numerical models are subjected to region-specific simulated ground motion time histories generated using validated seismological parameters. The variations in dynamic analysis results are evaluated using statistical tools for major structural and seismological parameters. The results reveal that the strength factor is the most influential structural parameter, whereas magnitude and distance have a significant impact on the response of idealized URM models as seismological parameters. Furthermore, the specific seismic performance exhibiting limited ductility capacity and the narrow margin of safety between the initial state of inelastic behavior and the ultimate (collapse) state for URM buildings is verified by the statistical approaches employed in this study. |
id |
RCAP_062e5213b5e2f1497efb960e0d346c05 |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/87201 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
The sensitivity of global structural parameters for unreinforced masonry buildings subjected to simulated ground motionsUnreinforced masonrySimplified modelsSimulated ground motionsDiscriminant analysisMultiple regression analysisThis research performs a parametric study based on Equivalent Single Degree of Freedom (ESDOF) models for simplified seismic analysis of unreinforced masonry (URM) structures. This is a necessary action due to the fact that it is not affordable to model and analyze populations of masonry buildings by using detailed continuum-based models during regional seismic damage and loss estimation studies. Hence, this study focuses on the sensitivity of major structural parameters of a selected idealized hysteretic model for URM buildings. The numerical models are subjected to region-specific simulated ground motion time histories generated using validated seismological parameters. The variations in dynamic analysis results are evaluated using statistical tools for major structural and seismological parameters. The results reveal that the strength factor is the most influential structural parameter, whereas magnitude and distance have a significant impact on the response of idealized URM models as seismological parameters. Furthermore, the specific seismic performance exhibiting limited ductility capacity and the narrow margin of safety between the initial state of inelastic behavior and the ultimate (collapse) state for URM buildings is verified by the statistical approaches employed in this study.The last author is financed by FCT/MCTES through national funds (PIDDAC) under the R&D Unit Institute for Sustainability and Innovation in Structural Engineering (ISISE), under reference UIDB/04029/2020 and under the Associate Laboratory Advanced Production and Intelligent Systems ARISE under reference LA/P/0112/2020.Multidisciplinary Digital Publishing Institute (MDPI)Universidade do MinhoKoc, Ahmet BahadirErberik, Murat AltugAskan, AysegulNaghshineh, Shaghayegh Karim Zadeh2023-08-132023-08-13T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/1822/87201engKoc, A.B.; Erberik, M.A.; Askan, A.; Karimzadeh, S. The Sensitivity of Global Structural Parameters for Unreinforced Masonry Buildings Subjected to Simulated Ground Motions. Buildings 2023, 13, 2060. https://doi.org/10.3390/buildings130820602075-530910.3390/buildings130820602060https://www.mdpi.com/2075-5309/13/8/2060info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-03-09T01:19:02Zoai:repositorium.sdum.uminho.pt:1822/87201Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T22:37:53.904181Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
The sensitivity of global structural parameters for unreinforced masonry buildings subjected to simulated ground motions |
title |
The sensitivity of global structural parameters for unreinforced masonry buildings subjected to simulated ground motions |
spellingShingle |
The sensitivity of global structural parameters for unreinforced masonry buildings subjected to simulated ground motions Koc, Ahmet Bahadir Unreinforced masonry Simplified models Simulated ground motions Discriminant analysis Multiple regression analysis |
title_short |
The sensitivity of global structural parameters for unreinforced masonry buildings subjected to simulated ground motions |
title_full |
The sensitivity of global structural parameters for unreinforced masonry buildings subjected to simulated ground motions |
title_fullStr |
The sensitivity of global structural parameters for unreinforced masonry buildings subjected to simulated ground motions |
title_full_unstemmed |
The sensitivity of global structural parameters for unreinforced masonry buildings subjected to simulated ground motions |
title_sort |
The sensitivity of global structural parameters for unreinforced masonry buildings subjected to simulated ground motions |
author |
Koc, Ahmet Bahadir |
author_facet |
Koc, Ahmet Bahadir Erberik, Murat Altug Askan, Aysegul Naghshineh, Shaghayegh Karim Zadeh |
author_role |
author |
author2 |
Erberik, Murat Altug Askan, Aysegul Naghshineh, Shaghayegh Karim Zadeh |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Koc, Ahmet Bahadir Erberik, Murat Altug Askan, Aysegul Naghshineh, Shaghayegh Karim Zadeh |
dc.subject.por.fl_str_mv |
Unreinforced masonry Simplified models Simulated ground motions Discriminant analysis Multiple regression analysis |
topic |
Unreinforced masonry Simplified models Simulated ground motions Discriminant analysis Multiple regression analysis |
description |
This research performs a parametric study based on Equivalent Single Degree of Freedom (ESDOF) models for simplified seismic analysis of unreinforced masonry (URM) structures. This is a necessary action due to the fact that it is not affordable to model and analyze populations of masonry buildings by using detailed continuum-based models during regional seismic damage and loss estimation studies. Hence, this study focuses on the sensitivity of major structural parameters of a selected idealized hysteretic model for URM buildings. The numerical models are subjected to region-specific simulated ground motion time histories generated using validated seismological parameters. The variations in dynamic analysis results are evaluated using statistical tools for major structural and seismological parameters. The results reveal that the strength factor is the most influential structural parameter, whereas magnitude and distance have a significant impact on the response of idealized URM models as seismological parameters. Furthermore, the specific seismic performance exhibiting limited ductility capacity and the narrow margin of safety between the initial state of inelastic behavior and the ultimate (collapse) state for URM buildings is verified by the statistical approaches employed in this study. |
publishDate |
2023 |
dc.date.none.fl_str_mv |
2023-08-13 2023-08-13T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://hdl.handle.net/1822/87201 |
url |
https://hdl.handle.net/1822/87201 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Koc, A.B.; Erberik, M.A.; Askan, A.; Karimzadeh, S. The Sensitivity of Global Structural Parameters for Unreinforced Masonry Buildings Subjected to Simulated Ground Motions. Buildings 2023, 13, 2060. https://doi.org/10.3390/buildings13082060 2075-5309 10.3390/buildings13082060 2060 https://www.mdpi.com/2075-5309/13/8/2060 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Multidisciplinary Digital Publishing Institute (MDPI) |
publisher.none.fl_str_mv |
Multidisciplinary Digital Publishing Institute (MDPI) |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799134937947832320 |