Resumo: OBJECTIVES: This study compared the diagnostic performance with adenosine-derived fractional flow reserve (FFR) ≤0.8 of contrast-based FFR (cFFR), resting distal pressure (Pd)/aortic pressure (Pa), and the instantaneous wave-free ratio (iFR). BACKGROUND: FFR objectively identifies lesions that benefit from medical therapy versus revascularization. However, FFR requires maximal vasodilation, usually achieved with adenosine. Radiographic contrast injection causes submaximal coronary hyperemia. Therefore, intracoronary contrast could provide an easy and inexpensive tool for predicting FFR. METHODS: We recruited patients undergoing routine FFR assessment and made paired, repeated measurements of all physiology metrics (Pd/Pa, iFR, cFFR, and FFR). Contrast medium and dose were per local practice, as was the dose of intracoronary adenosine. Operators were encouraged to perform both intracoronary and intravenous adenosine assessments and a final drift check to assess wire calibration. A central core lab analyzed blinded pressure tracings in a standardized fashion. RESULTS: A total of 763 subjects were enrolled from 12 international centers. Contrast volume was 8 ± 2 ml per measurement, and 8 different contrast media were used. Repeated measurements of each metric showed a bias <0.005, but a lower SD (less variability) for cFFR than resting indexes. Although Pd/Pa and iFR demonstrated equivalent performance against FFR ≤0.8 (78.5% vs. 79.9% accuracy; p = 0.78; area under the receiver-operating characteristic curve: 0.875 vs. 0.881; p = 0.35), cFFR improved both metrics (85.8% accuracy and 0.930 area; p < 0.001 for each) with an optimal binary threshold of 0.83. A hybrid decision-making strategy using cFFR required adenosine less often than when based on either Pd/Pa or iFR. CONCLUSIONS: cFFR provides diagnostic performance superior to that of Pd/Pa or iFR for predicting FFR. For clinical scenarios or health care systems in which adenosine is contraindicated or prohibitively expensive, cFFR offers a universal technique to simplify invasive coronary physiological assessments. Yet FFR remains the reference standard for diagnostic certainty as even cFFR reached only ∼85% agreement.
id RCAP_0c38725d96f7f0233ef0d450822b2a69
oai_identifier_str oai:repositorio.hff.min-saude.pt:10400.10/1821
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Continuum of Vasodilator Stress From Rest to Contrast Medium to Adenosine Hyperemia for Fractional Flow Reserve Assessment.Cardiac catheterizationCateterização cardíacaCoronary artery diseaseDoença das artérias coronáriasVasodilatorsVasodilatadoresOBJECTIVES: This study compared the diagnostic performance with adenosine-derived fractional flow reserve (FFR) ≤0.8 of contrast-based FFR (cFFR), resting distal pressure (Pd)/aortic pressure (Pa), and the instantaneous wave-free ratio (iFR). BACKGROUND: FFR objectively identifies lesions that benefit from medical therapy versus revascularization. However, FFR requires maximal vasodilation, usually achieved with adenosine. Radiographic contrast injection causes submaximal coronary hyperemia. Therefore, intracoronary contrast could provide an easy and inexpensive tool for predicting FFR. METHODS: We recruited patients undergoing routine FFR assessment and made paired, repeated measurements of all physiology metrics (Pd/Pa, iFR, cFFR, and FFR). Contrast medium and dose were per local practice, as was the dose of intracoronary adenosine. Operators were encouraged to perform both intracoronary and intravenous adenosine assessments and a final drift check to assess wire calibration. A central core lab analyzed blinded pressure tracings in a standardized fashion. RESULTS: A total of 763 subjects were enrolled from 12 international centers. Contrast volume was 8 ± 2 ml per measurement, and 8 different contrast media were used. Repeated measurements of each metric showed a bias <0.005, but a lower SD (less variability) for cFFR than resting indexes. Although Pd/Pa and iFR demonstrated equivalent performance against FFR ≤0.8 (78.5% vs. 79.9% accuracy; p = 0.78; area under the receiver-operating characteristic curve: 0.875 vs. 0.881; p = 0.35), cFFR improved both metrics (85.8% accuracy and 0.930 area; p < 0.001 for each) with an optimal binary threshold of 0.83. A hybrid decision-making strategy using cFFR required adenosine less often than when based on either Pd/Pa or iFR. CONCLUSIONS: cFFR provides diagnostic performance superior to that of Pd/Pa or iFR for predicting FFR. For clinical scenarios or health care systems in which adenosine is contraindicated or prohibitively expensive, cFFR offers a universal technique to simplify invasive coronary physiological assessments. Yet FFR remains the reference standard for diagnostic certainty as even cFFR reached only ∼85% agreement.ElsevierRepositório do Hospital Prof. Doutor Fernando FonsecaJohnson, NJeremias, AZimmermann, FAdjedj, JWitt, NHennigan, BKoo, BMaehara, AMatsumura, MBarbato, EEsposito, GTrimarco, BRioufol, GPark, SYang, HBaptista, SBChrysant, GLeone, ABerry, CDe Bruyne, BGould, KKirkeeide, ROldroyd, KPijls, NFearon, W2017-03-13T14:33:02Z2016-01-01T00:00:00Z2016-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.10/1821engJACC Cardiovasc Interv. 2016 Apr 25;9(8):757-671876-760510.1016/j.jcin.2015.12.273info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-09-20T15:52:33Zoai:repositorio.hff.min-saude.pt:10400.10/1821Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:52:51.984257Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Continuum of Vasodilator Stress From Rest to Contrast Medium to Adenosine Hyperemia for Fractional Flow Reserve Assessment.
title Continuum of Vasodilator Stress From Rest to Contrast Medium to Adenosine Hyperemia for Fractional Flow Reserve Assessment.
spellingShingle Continuum of Vasodilator Stress From Rest to Contrast Medium to Adenosine Hyperemia for Fractional Flow Reserve Assessment.
Johnson, N
Cardiac catheterization
Cateterização cardíaca
Coronary artery disease
Doença das artérias coronárias
Vasodilators
Vasodilatadores
title_short Continuum of Vasodilator Stress From Rest to Contrast Medium to Adenosine Hyperemia for Fractional Flow Reserve Assessment.
title_full Continuum of Vasodilator Stress From Rest to Contrast Medium to Adenosine Hyperemia for Fractional Flow Reserve Assessment.
title_fullStr Continuum of Vasodilator Stress From Rest to Contrast Medium to Adenosine Hyperemia for Fractional Flow Reserve Assessment.
title_full_unstemmed Continuum of Vasodilator Stress From Rest to Contrast Medium to Adenosine Hyperemia for Fractional Flow Reserve Assessment.
title_sort Continuum of Vasodilator Stress From Rest to Contrast Medium to Adenosine Hyperemia for Fractional Flow Reserve Assessment.
author Johnson, N
author_facet Johnson, N
Jeremias, A
Zimmermann, F
Adjedj, J
Witt, N
Hennigan, B
Koo, B
Maehara, A
Matsumura, M
Barbato, E
Esposito, G
Trimarco, B
Rioufol, G
Park, S
Yang, H
Baptista, SB
Chrysant, G
Leone, A
Berry, C
De Bruyne, B
Gould, K
Kirkeeide, R
Oldroyd, K
Pijls, N
Fearon, W
author_role author
author2 Jeremias, A
Zimmermann, F
Adjedj, J
Witt, N
Hennigan, B
Koo, B
Maehara, A
Matsumura, M
Barbato, E
Esposito, G
Trimarco, B
Rioufol, G
Park, S
Yang, H
Baptista, SB
Chrysant, G
Leone, A
Berry, C
De Bruyne, B
Gould, K
Kirkeeide, R
Oldroyd, K
Pijls, N
Fearon, W
author2_role author
author
author
author
author
author
author
author
author
author
author
author
author
author
author
author
author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Repositório do Hospital Prof. Doutor Fernando Fonseca
dc.contributor.author.fl_str_mv Johnson, N
Jeremias, A
Zimmermann, F
Adjedj, J
Witt, N
Hennigan, B
Koo, B
Maehara, A
Matsumura, M
Barbato, E
Esposito, G
Trimarco, B
Rioufol, G
Park, S
Yang, H
Baptista, SB
Chrysant, G
Leone, A
Berry, C
De Bruyne, B
Gould, K
Kirkeeide, R
Oldroyd, K
Pijls, N
Fearon, W
dc.subject.por.fl_str_mv Cardiac catheterization
Cateterização cardíaca
Coronary artery disease
Doença das artérias coronárias
Vasodilators
Vasodilatadores
topic Cardiac catheterization
Cateterização cardíaca
Coronary artery disease
Doença das artérias coronárias
Vasodilators
Vasodilatadores
description OBJECTIVES: This study compared the diagnostic performance with adenosine-derived fractional flow reserve (FFR) ≤0.8 of contrast-based FFR (cFFR), resting distal pressure (Pd)/aortic pressure (Pa), and the instantaneous wave-free ratio (iFR). BACKGROUND: FFR objectively identifies lesions that benefit from medical therapy versus revascularization. However, FFR requires maximal vasodilation, usually achieved with adenosine. Radiographic contrast injection causes submaximal coronary hyperemia. Therefore, intracoronary contrast could provide an easy and inexpensive tool for predicting FFR. METHODS: We recruited patients undergoing routine FFR assessment and made paired, repeated measurements of all physiology metrics (Pd/Pa, iFR, cFFR, and FFR). Contrast medium and dose were per local practice, as was the dose of intracoronary adenosine. Operators were encouraged to perform both intracoronary and intravenous adenosine assessments and a final drift check to assess wire calibration. A central core lab analyzed blinded pressure tracings in a standardized fashion. RESULTS: A total of 763 subjects were enrolled from 12 international centers. Contrast volume was 8 ± 2 ml per measurement, and 8 different contrast media were used. Repeated measurements of each metric showed a bias <0.005, but a lower SD (less variability) for cFFR than resting indexes. Although Pd/Pa and iFR demonstrated equivalent performance against FFR ≤0.8 (78.5% vs. 79.9% accuracy; p = 0.78; area under the receiver-operating characteristic curve: 0.875 vs. 0.881; p = 0.35), cFFR improved both metrics (85.8% accuracy and 0.930 area; p < 0.001 for each) with an optimal binary threshold of 0.83. A hybrid decision-making strategy using cFFR required adenosine less often than when based on either Pd/Pa or iFR. CONCLUSIONS: cFFR provides diagnostic performance superior to that of Pd/Pa or iFR for predicting FFR. For clinical scenarios or health care systems in which adenosine is contraindicated or prohibitively expensive, cFFR offers a universal technique to simplify invasive coronary physiological assessments. Yet FFR remains the reference standard for diagnostic certainty as even cFFR reached only ∼85% agreement.
publishDate 2016
dc.date.none.fl_str_mv 2016-01-01T00:00:00Z
2016-01-01T00:00:00Z
2017-03-13T14:33:02Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.10/1821
url http://hdl.handle.net/10400.10/1821
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv JACC Cardiovasc Interv. 2016 Apr 25;9(8):757-67
1876-7605
10.1016/j.jcin.2015.12.273
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799130394712342529